AJArvind Jain

Arvind Jain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arvind Jain has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthesis and Evaluation of Novel Piperazine Hybrids as Promising Anticancer Agents

    by Vaibhav Daund, Pooja Agarwal, Arvind Jain, Pratichi Singh, Ameya Hebale

    This study aimed to synthesise a novel series of piperazine analogues (3a-k) having anticancer potential against MCF-7, MDA-MB-231 and HeLa cell lines. Structure of the synthesised analogues were confirmed through NMR and biological evaluation were done through MTT assay taking doxorubicin as a reference standard. The synthesised derivatives exhibited appreciable cytotoxicity at low concentrations. Molecular docking examined their binding interactions with estrogen receptor-α (ERα) and epidermal growth factor receptor (EGFR), associated with MCF-7 and MDA-MB-231 cell lines, respectively, providing structural insight into their anticancer potential. The results revealed that the synthesised derivative 3h has potential binding affinity hence blocking the activity. Therefore, the results obtained from in vitro and in silico studies identify the synthesised piperazine derivatives as promising lead compounds for further anticancer optimization. The IC50 values support this observation, with compounds 3g, 3h and 3i exhibiting the highest cytotoxic activity among the other derivatives evaluated.

  • Impact Assessment of Electroplating in the Leaching of Harmful Metals from Utensils

    by Deepak Sharma, Divya Tripathy, Arvind Jain

    Electroplating is a widely used technique in the manufacturing of utensils for household and commercial use. This process involves the deposition of a metal coating onto a base material, such as steel or brass, to improve the aesthetics, durability, and corrosion resistance of the utensil. Several studies have investigated the migration of heavy metals from utensils, but there is a lack of research specifically focused on the impact of electroplating on this phenomenon. Therefore, this research article aims to assess the impact of electroplating by analyzing the migration of heavy metals from such utensils. The objective of this research is to assess the impact of electroplating on the migration of heavy metals from utensils. The research also aims to evaluate the impact of coating thickness. Stainless‐steel and brass utensils (Plate, Tumbler, and Bowl) are purchased. The samples are analyzed as per standard test methods based on inductively coupled plasma mass spectrometry (ICP‐MS) techniques. Leaching stimulant is used for extraction process. Testing is performed in an ISO/IEC 17025: 2017 accredited laboratory. The experiments reveal that the electroplating process decreased the migration of lead from the utensils. These findings highlight the need for stricter regulations and standards to ensure the safety of electroplated utensils.


  • A comparative study of chiral separation of proton pump inhibitors by supercritical fluid chromatography and high‐performance liquid chromatography

    by Rupak Raja, Syed Dilshad Alam, Vikas Srisath, Arvind Kumar Jain, Zeid A. Alothman, Abdallah A. A. Mohammed, Mohammad Ataul Islam, Tahir Bhatt, Imran Ali

    A comparative study of chiral separation of pantoprazole and rabeprazole is carried out using supercritical fluid chromatography and high-performance liquid chromatography. The columns used were Chiralpak IA and Chiralpak IE. The best mobile phase in supercritical fluid chromatography was carbon dioxide-0.2% triethylamine in methanol (60:40) and 0.1% triethylamine in n-hexane-ethanol (50:50) in high-performance liquid chromatography. For supercritical fluid chromatography, values of the retention factor of pantoprazole enantiomers were 3.97 and 4.88. These values for rabeprazole enantiomers were 6.10 and 7.52. The values of separation and resolution factor for pantoprazole and rabeprazole were 1.23 and 1.23 and 2.20 and 3.36. Similarly, for high-performance liquid chromatography, the values of retention factor for enantiomers of pantoprazole were 4.02 and 7.32. These values for rabeprazole enantiomers were 5.32 and 7.88, respectively. The values of separation and resolution factor for pantoprazole and rabeprazole were 1.82 and 1.48 and 9.22 and 6.58. A comparison was carried out, which confirmed supercritical fluid chromatography as the best method due to its fastness, eco-friendly and inexpensiveness. The reported methods are effective, efficient and reproducible and may be used to separate and identify pantoprazole and rabeprazole in any unknown samples. This article is protected by copyright. All rights reserved


  • Effects of Isolated Post-challenge Hyperglycemia on Mortality in American Indians

    by Weiquan Lu, Helaine E. Resnick, Arvind K. Jain, Lucile L. Adams-Campbell, Kathleen A. Jablonski, Adrienne M. Gottlieb, David C. Robbins, Barbara V. Howard