ABAmrita Pandita Bhatia

Amrita Pandita Bhatia

*This is an algorithmically generated author record based on publicly available information.

Amrita Pandita Bhatia has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Abhijeet Alok

    Department of Oral Medicine and Radiology, Sarjug Dental College and Hospital, Darbhanga, Bihar, India

    2 shared publications
  • Mukesh Kumar

    Department of Oral & Maxillofacial Surgery, Shree Bankey Bihari Dental College, Masuri, Ghaziabad, Uttar Pradesh, India

    2 shared publications
  • Rahul Tiwari

    Department of Oral and Maxillofacial Surgery, Narsinhbhai Patel Dental College and Hospital, Sankalchand Patel University, Visnagar, Gujarat, India

    2 shared publications
  • Rishabh Yadav

    Department of Radiology, Prasad Medical College, Lucknow, Uttar Pradesh, India

    2 shared publications
  • Apurva Lambat

    Prosthodontics, Shri. Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College, Ahmednagar, IND

    1 shared publication
  • Ifath Nazia Ghori

    Department of Computer Science, Jazan University, Jazan, Saudi Arabia

    1 shared publication

Latest Publications

  • Open Access

    Artificial intelligence improves radiologist workflow and assessment of image quality accuracy

    by Rishabh Yadav, Mukesh Kumar, Ifath Nazia Ghori, Abhijeet Alok, Amrita Pandita Bhatia, Santosh Kumar Kotnoor, Rahul Tiwari

    Increasing imaging volumes and workflow pressures make consistent image quality assessment (IQA) challenging for radiologists in routine clinical practice. Artificial intelligence (AI) systems have recently been introduced to support quality control tasks, yet real-world evidence on their impact on radiologist workflow and diagnostic performance remains limited. Therefore, it is of interest to assess the effect of AI-IQA module of PACS/worklist on radiological workflow and accuracy in identifying suboptimal CT/MRI tests. Workflow (IQA time, TTFR and TAT) and IQA performance (sensitivity, specificity, kappa) metrics were evaluated in two groups (before and after 8 weeks of AI integration) and compared to an expert reference standard. AI integration lowered median IQA task time/examination and improved report turnaround time and improved radiologist sensitivity to suboptimal IQA without affecting specificity. Thus, we show AI-assisted IQA as a scalable tool to enhance the quality control and operation performance in the routine clinical practice


  • Open Access

    Diagnostic accuracy of radiography techniques for musculoskeletal disorders

    by Rishabh Yadav, Rinku Choudhury, Abhijeet Alok, Mukesh Kumar, Amrita Pandita Bhatia, Tanvi Hirani, Rahul Tiwari

    Conventional radiography often fails to detect early or subtle musculoskeletal pathology because of limited sensitivity and anatomical overlap. Therefore, it is of interest to study prospectively evaluated CR, DT, LDCT and MRI against a composite reference standard in a tertiary MSK unit. Hence, a total of 120 patients were included in the study, of which 54 had positive findings regarding clinically significant musculoskeletal pathology. MRI showed the highest sensitivities (98.1%) and overall accuracy (95.8%), followed by low-dose CT with sensitivity(s) of 81.5% and an accuracy of 90.0%. Tomosynthesis was superior to radiography for detection and offered a clinically useful intermediate alternative for indeterminate radiographs

  • Open Access

    A Comparative Analysis of Conventional and Chat-Generative Pre-trained Transformer-Assisted Teaching Methods in Undergraduate Dental Education

    by Amrita P. Bhatia, Apurva Lambat, Teerthesh Jain

    Introduction: In the present era, individuals have the ability to improve their study organization, attendance in classes, and use of mnemonics via the utilization of contemporary technology. The use of the open AI-based application Chat Generative Pre-Trained Transformer (ChatGPT) in dentistry is a developing domain, and the integration of this technology into dental education relies on the accessibility and efficacy of AI technology, as well as the readiness of institutions to adopt it. Furthermore, it is crucial to contemplate the possible ethical ramifications associated with the utilization of AI in the field of dentistry, as well as the need for dental practitioners to have adequate training in its use. In order to include the Chat Generative Pre-Trained Transformer in the dentistry curriculum, a thorough evaluation and consultation with field specialists would be necessary. This study aimed to determine whether the Chat Generative Pre-Trained Transformer is more effective than conventional teaching methods in teaching undergraduate dental students. Method: Comparative research was conducted at Shri. Yashwantrao Chavan Memorial Medical and Rural Development Foundation's Dental College, Ahmednagar. Computer-generated random numbers were used to divide 100 students into two groups. Each group consists of 50 students. A didactic lecture was given using PowerPoint (Redmond, WA: Microsoft Corp.) for both groups. Group A was given textbooks to read and Group B used the Chat Generative Pre-Trained Transformer. An online questionnaire using Google Forms (Menlo Park, CA: Google LLC), which had been pre-validated, was sent via email to both groups. The pre- and post-test scores are then compared using the t-test. Result: The calculated t-value is 12.263 (at 81 degrees of freedom) and the p-value is 0.000, which is less than 0.01. Therefore, the null hypothesis is rejected, and it is concluded that conventional method scores and ChatGPT method scores for the post-test have a high significant difference. Also, it is observed that the mean scores for the conventional method are higher than the mean scores for the ChatGPT method for the post-test. Conclusion: It has been concluded from the study that traditional teaching methods are more effective for learning than understanding ChatGPT.


  • Open Access

    Impact of the Habit of Alcohol Consumption on the Success of the Implants: A Retrospective Study

    by Amrita Pandita Bhatia, S. N. Rupamalini, Krishna Veni Sathi, Vishnu G. Marella, Siva Kumar Pendyala, Jayendra Purohit, Rahul Vc Tiwari

    Introduction: A recent study has demonstrated that social factors have an impact on the condition of dental implants. The present investigation investigated how varied alcohol intake quantities might alter the condition of dental implants and related peri-implant inflammation. Materials and Methods: This retrospective research was piloted in a tertiary care center, and implants inserted between 2010 and 2022 were evaluated through a retrospective cohort analysis. Within 3 months following implant implantation, information on alcohol intake was gathered from the health maintenance records and employed as the predictor variable. The implant results as well as peri-implantitis were examined at follow-up visits. Using the logistic regression model, the Wald test analysis analyzed the statistical consequences of each parameter. The findings were translated using an odds ratio that was determined with a 95% confidence level. The data were generated and analyzed using descriptive statistics, with statistical significance defined as P < 0.05. Results: At the time of implant placement, the enrolled patients were 59 ± 11.3 years old on average. The median time before peri-implantitis occurred was 31.3 ± 22.2 months. Within the first 2 years following implant implantation, the majority of people experienced peri-implantitis. The incidence of peri-implantitis was the lowest among light and moderate alcoholics (11.5%) and the highest among heavy alcoholics (46.2%). Moderate alcohol use was associated with a 79.1% decrease in peri-implantitis when compared to not drinking (P = 0.0365), whereas light alcohol consumption was connected to a 51.3% decrease (P = 0.026). The incidence of peri-implantitis among heavy drinkers was significantly significant (P = 0.0001). Conclusion: According to the findings of the current retrospective cohort analysis, drinking alcohol at mild-to-moderate levels is connected to a reduction in the incidence rate of peri-implantitis compared to heavy drinkers. In contrast, high alcohol consumption was found to be associated with an increase in the prevalence of peri-implantitis among the participants who had dental implants.