Yulong Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Yulong Xia has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bo Deng
Department of Neurosurgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuanjiagang, Yuzhong District, Chongqing, China, 86 13638354200
2 shared publications - Jie Li
School of Computer Science and Engineering, Chongqing University of Science and Technology, Chongqing, China
2 shared publications - Li Jiang
The First Affiliated Hospital of Chongqing Medical University
2 shared publications - Quanhong Shi
Department of Neurosurgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China
2 shared publications - Wei Dan
Department of Neurosurgery, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuanjiagang, Yuzhong District, Chongqing, China, 86 13638354200
2 shared publications - Yanfeng Xie
The First Affiliated Hospital of Chongqing Medical University
2 shared publications
Latest Publications
- Open Access
- 12 June 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e66055
Knowledge Graph–Enhanced Deep Learning Model (H-SYSTEM) for Hypertensive Intracerebral Hemorrhage: Model Development and Validation
Background: Although much progress has been made in artificial intelligence (AI), several challenges remain substantial obstacles to the development and translation of AI systems into clinical practice. Even large language models, which show excellent performance on various tasks, have progressed slowly in clinical practice tasks. Providing precise and explainable treatment plans with personalized details remains a big challenge for AI systems due to both the highly specialized medical knowledge required and patients’ complicated conditions. Objective: This study aimed to develop an explainable and efficient decision support system named H-SYSTEM to assist neurosurgeons in diagnosing and treating patients with hypertensive intracerebral hemorrhage. The system was designed to address the limitations of existing AI systems by integrating a medical domain knowledge graph to enhance decision-making accuracy and explainability. Methods: The H-SYSTEM consists of 3 main modules: the key named entity recognition (NER) module, the semantic analysis and representation module, and the reasoning module. Furthermore, we constructed a medical domain knowledge graph for hypertensive intracerebral hemorrhage, named HKG, which served as an external knowledge brain of the H-SYSTEM to enhance its text recognition and automated decision-making capability. The HKG was exploited to guide the training of the semantic analysis and representation module and reasoning module, which makes the output of the H-SYSTEM more explainable. To assess the performance of the H-SYSTEM, we compared it with doctors and different large language models. Results: The outputs based on HKG showed reliable performance as compared with neurosurgical doctors, with an overall accuracy of 94.87%. The bidirectional encoder representations from transformers, inflated dilated convolutional neural network, bidirectional long short-term memory, and conditional random fields (BERT-IDCNN-BiLSTM-CRF) model was used as the key NER module of the H-SYSTEM due to its fast convergence and efficient extraction of key named entities, achieved the highest performance among 7 key NER models (precision=92.03, recall=90.22, and F1-score=91.11), significantly outperforming the others. The H-SYSTEM achieved an overall accuracy of 91.74% in treatment plans, showing significant consistency with the gold standard (P<.05), with diagnostic measures achieving 88.18% accuracy, 97.03% area under the curve (AUC), and a κ of 0.874; surgical therapy achieving 98.53% accuracy, 98.53% AUC, and a κ of 0.971; and rescue therapies achieving 89.50% accuracy, 94.67% AUC, and a κ of 0.923 (all P<.05). Furthermore, the H-SYSTEM showed high reliability and efficiency when compared to doctors and ChatGPT, achieving statistically higher accuracy (95.26% vs 91.48%, P<.05). Additionally, the H-SYSTEM achieved a total accuracy of 92.22% (ranging from 91.14% to 95.35%) in treatment plans for 605 additional patients from 6 different medical centers. Conclusions: The H-SYSTEM showed significantly high efficiency and generalization capacity in processing electronic medical records, and it provided explainable and elaborate treatment plans. Therefore, it has the potential to provide neurosurgeons with rapid and reliable decision support, especially in emergency conditions. The knowledge graph–enhanced deep-learning model exhibited excellent performance in the clinical practice tasks.
- 12 June 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e66055
Open AccessKnowledge Graph–Enhanced Deep Learning Model (H-SYSTEM) for Hypertensive Intracerebral Hemorrhage: Model Development and Validation
Background: Although much progress has been made in artificial intelligence (AI), several challenges remain substantial obstacles to the development and translation of AI systems into clinical practice. Even large language models, which show excellent performance on various tasks, have progressed slowly in clinical practice tasks. Providing precise and explainable treatment plans with personalized details remains a big challenge for AI systems due to both the highly specialized medical knowledge required and patients’ complicated conditions. Objective: This study aimed to develop an explainable and efficient decision support system named H-SYSTEM to assist neurosurgeons in diagnosing and treating patients with hypertensive intracerebral hemorrhage. The system was designed to address the limitations of existing AI systems by integrating a medical domain knowledge graph to enhance decision-making accuracy and explainability. Methods: The H-SYSTEM consists of 3 main modules: the key named entity recognition (NER) module, the semantic analysis and representation module, and the reasoning module. Furthermore, we constructed a medical domain knowledge graph for hypertensive intracerebral hemorrhage, named HKG, which served as an external knowledge brain of the H-SYSTEM to enhance its text recognition and automated decision-making capability. The HKG was exploited to guide the training of the semantic analysis and representation module and reasoning module, which makes the output of the H-SYSTEM more explainable. To assess the performance of the H-SYSTEM, we compared it with doctors and different large language models. Results: The outputs based on HKG showed reliable performance as compared with neurosurgical doctors, with an overall accuracy of 94.87%. The bidirectional encoder representations from transformers, inflated dilated convolutional neural network, bidirectional long short-term memory, and conditional random fields (BERT-IDCNN-BiLSTM-CRF) model was used as the key NER module of the H-SYSTEM due to its fast convergence and efficient extraction of key named entities, achieved the highest performance among 7 key NER models (precision=92.03, recall=90.22, and F1-score=91.11), significantly outperforming the others. The H-SYSTEM achieved an overall accuracy of 91.74% in treatment plans, showing significant consistency with the gold standard (P<.05), with diagnostic measures achieving 88.18% accuracy, 97.03% area under the curve (AUC), and a κ of 0.874; surgical therapy achieving 98.53% accuracy, 98.53% AUC, and a κ of 0.971; and rescue therapies achieving 89.50% accuracy, 94.67% AUC, and a κ of 0.923 (all P<.05). Furthermore, the H-SYSTEM showed high reliability and efficiency when compared to doctors and ChatGPT, achieving statistically higher accuracy (95.26% vs 91.48%, P<.05). Additionally, the H-SYSTEM achieved a total accuracy of 92.22% (ranging from 91.14% to 95.35%) in treatment plans for 605 additional patients from 6 different medical centers. Conclusions: The H-SYSTEM showed significantly high efficiency and generalization capacity in processing electronic medical records, and it provided explainable and elaborate treatment plans. Therefore, it has the potential to provide neurosurgeons with rapid and reliable decision support, especially in emergency conditions. The knowledge graph–enhanced deep-learning model exhibited excellent performance in the clinical practice tasks.
- 29 February 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 37 (4) , 1505-1515
SC-Unext: A Lightweight Image Segmentation Model with Cellular Mechanism for Breast Ultrasound Tumor Diagnosis
Automatic breast ultrasound image segmentation plays an important role in medical image processing. However, current methods for breast ultrasound segmentation suffer from high computational complexity and large model parameters, particularly when dealing with complex images. In this paper, we take the Unext network as a basis and utilize its encoder-decoder features. And taking inspiration from the mechanisms of cellular apoptosis and division, we design apoptosis and division algorithms to improve model performance. We propose a novel segmentation model which integrates the division and apoptosis algorithms and introduces spatial and channel convolution blocks into the model. Our proposed model not only improves the segmentation performance of breast ultrasound tumors, but also reduces the model parameters and computational resource consumption time. The model was evaluated on the breast ultrasound image dataset and our collected dataset. The experiments show that the SC-Unext model achieved Dice scores of 75.29% and accuracy of 97.09% on the BUSI dataset, and on the collected dataset, it reached Dice scores of 90.62% and accuracy of 98.37%. Meanwhile, we conducted a comparison of the model’s inference speed on CPUs to verify its efficiency in resource-constrained environments. The results indicated that the SC-Unext model achieved an inference speed of 92.72 ms per instance on devices equipped only with CPUs. The model’s number of parameters and computational resource consumption are 1.46M and 2.13 GFlops, respectively, which are lower compared to other network models. Due to its lightweight nature, the model holds significant value for various practical applications in the medical field.
- 29 February 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 37 (4) , 1505-1515
SC-Unext: A Lightweight Image Segmentation Model with Cellular Mechanism for Breast Ultrasound Tumor Diagnosis
Automatic breast ultrasound image segmentation plays an important role in medical image processing. However, current methods for breast ultrasound segmentation suffer from high computational complexity and large model parameters, particularly when dealing with complex images. In this paper, we take the Unext network as a basis and utilize its encoder-decoder features. And taking inspiration from the mechanisms of cellular apoptosis and division, we design apoptosis and division algorithms to improve model performance. We propose a novel segmentation model which integrates the division and apoptosis algorithms and introduces spatial and channel convolution blocks into the model. Our proposed model not only improves the segmentation performance of breast ultrasound tumors, but also reduces the model parameters and computational resource consumption time. The model was evaluated on the breast ultrasound image dataset and our collected dataset. The experiments show that the SC-Unext model achieved Dice scores of 75.29% and accuracy of 97.09% on the BUSI dataset, and on the collected dataset, it reached Dice scores of 90.62% and accuracy of 98.37%. Meanwhile, we conducted a comparison of the model’s inference speed on CPUs to verify its efficiency in resource-constrained environments. The results indicated that the SC-Unext model achieved an inference speed of 92.72 ms per instance on devices equipped only with CPUs. The model’s number of parameters and computational resource consumption are 1.46M and 2.13 GFlops, respectively, which are lower compared to other network models. Due to its lightweight nature, the model holds significant value for various practical applications in the medical field.
- 4 February 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 136, 182-190
APOE gene polymorphism alters cerebral oxygen saturation and quantitative EEG in early-stage traumatic brain injury
- 4 February 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 136, 182-190
APOE gene polymorphism alters cerebral oxygen saturation and quantitative EEG in early-stage traumatic brain injury