Nurfarhana Mohamad Sapiee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nurfarhana Mohamad Sapiee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Mahmoud Muhanad Fadhel
Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, Bangi 43600, Malaysia
3 shared publications - Abdulwahhab Essa Hamzah
Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Photonics Technology Laboratory, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia
2 shared publications - Mohd Saiful Dzulkefly Zan
Center of Advanced Electronic and Communication Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia
2 shared publications - Norazida Ali
Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, Bangi 43600, Malaysia
2 shared publications - Norhana Arsad
Universiti Kebangsaan Malaysia, UKM
2 shared publications - Ahmad Ashrif Abu Bakar
Photonics Technology Laboratory, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
1 shared publication
Latest Publications
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 4531-4541
Fast and Accurate Measurement in BOTDA Fiber Sensor Through the Application of Filtering Techniques in Frequency and Time Domains
This study introduces a new approach to enhance the measurement speed in the suggested system-on-chip (SoC) by incorporating quadratic least mean square (LMS) filtering with moving average (MA) and moving median (MM) filters at a low-averaging stage. The use of MA and MM filters in the frequency and time domains yields a significant enhancement in the reliability and accuracy of the Brillouin frequency shift. Our method, as demonstrated in this study, exhibits a significantly reduced latency, which ranges from 14 to 1563 times faster than Brillouin optical time-domain analysis (BOTDA) systems that rely on an oscilloscope and a computer for data processing, and the BOTDA system utilising SoC with LMS filtering alone. Compared with LMS curve fitting alone, the implementation of this technique greatly enhances accuracy with low averages by 84%. These filters enable the identification of minor disruptions along the cable. The proposed method successfully detects small variations in Brillouin frequency whilst maintaining the spatial resolution of sensors. The deployed filters result in a spatial resolution ranging from 1.6 m to 1.5 m, which demonstrates greater constancy than the normal range of 2–1.6 m. The present study successfully employs filtering techniques in the frequency and time domains by incorporating low averaging and a broad dynamic range. The use of SoC technology in BOTDA improves measurement speed, accuracy and the preservation of spatial resolution constancy. However, the measurable fibre length is limited due to AC coupling on the analogue-to-digital converter board. The algorithm and dataset are publicly available at Github.
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (4) , 4531-4541
Fast and Accurate Measurement in BOTDA Fiber Sensor Through the Application of Filtering Techniques in Frequency and Time Domains
This study introduces a new approach to enhance the measurement speed in the suggested system-on-chip (SoC) by incorporating quadratic least mean square (LMS) filtering with moving average (MA) and moving median (MM) filters at a low-averaging stage. The use of MA and MM filters in the frequency and time domains yields a significant enhancement in the reliability and accuracy of the Brillouin frequency shift. Our method, as demonstrated in this study, exhibits a significantly reduced latency, which ranges from 14 to 1563 times faster than Brillouin optical time-domain analysis (BOTDA) systems that rely on an oscilloscope and a computer for data processing, and the BOTDA system utilising SoC with LMS filtering alone. Compared with LMS curve fitting alone, the implementation of this technique greatly enhances accuracy with low averages by 84%. These filters enable the identification of minor disruptions along the cable. The proposed method successfully detects small variations in Brillouin frequency whilst maintaining the spatial resolution of sensors. The deployed filters result in a spatial resolution ranging from 1.6 m to 1.5 m, which demonstrates greater constancy than the normal range of 2–1.6 m. The present study successfully employs filtering techniques in the frequency and time domains by incorporating low averaging and a broad dynamic range. The use of SoC technology in BOTDA improves measurement speed, accuracy and the preservation of spatial resolution constancy. However, the measurable fibre length is limited due to AC coupling on the analogue-to-digital converter board. The algorithm and dataset are publicly available at Github.
- Open Access
- 12 September 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (9) , 2367
A Review on Rhenium Disulfide: Synthesis Approaches, Optical Properties, and Applications in Pulsed Lasers
Rhenium Disulfide (ReS2) has evolved as a novel 2D transition-metal dichalcogenide (TMD) material which has promising applications in optoelectronics and photonics because of its distinctive anisotropic optical properties. Saturable absorption property of ReS2 has been utilized to fabricate saturable absorber (SA) devices to generate short pulses in lasers systems. The results were outstanding, including high-repetition-rate pulses, large modulation depth, multi-wavelength pulses, broadband operation and low saturation intensity. In this review, we emphasize on formulating SAs based on ReS2 to produce pulsed lasers in the visible, near-infrared and mid-infrared wavelength regions with pulse durations down to femtosecond using mode-locking or Q-switching technique. We outline ReS2 synthesis techniques and integration platforms concerning solid-state and fiber-type lasers. We discuss the laser performance based on SAs attributes. Lastly, we draw conclusions and discuss challenges and future directions that will help to advance the domain of ultrafast photonic technology.
- 12 September 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (9) , 2367
Open AccessA Review on Rhenium Disulfide: Synthesis Approaches, Optical Properties, and Applications in Pulsed Lasers
Rhenium Disulfide (ReS2) has evolved as a novel 2D transition-metal dichalcogenide (TMD) material which has promising applications in optoelectronics and photonics because of its distinctive anisotropic optical properties. Saturable absorption property of ReS2 has been utilized to fabricate saturable absorber (SA) devices to generate short pulses in lasers systems. The results were outstanding, including high-repetition-rate pulses, large modulation depth, multi-wavelength pulses, broadband operation and low saturation intensity. In this review, we emphasize on formulating SAs based on ReS2 to produce pulsed lasers in the visible, near-infrared and mid-infrared wavelength regions with pulse durations down to femtosecond using mode-locking or Q-switching technique. We outline ReS2 synthesis techniques and integration platforms concerning solid-state and fiber-type lasers. We discuss the laser performance based on SAs attributes. Lastly, we draw conclusions and discuss challenges and future directions that will help to advance the domain of ultrafast photonic technology.
- Open Access
- 27 July 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (8) , 253
Comprehensive Review Tapered Optical Fiber Configurations for Sensing Application: Trend and Challenges
Understanding environmental information is necessary for functions correlated with human activities to improve healthcare quality and reduce ecological risk. Tapered optical fibers reduce some limitations of such devices and can be considerably more responsive to fluorescence and absorption properties changes. Data have been collected from reliable sources such as Science Direct, IEEE Xplore, Scopus, Web of Science, PubMed, and Google Scholar. In this narrative review, we have summarized and analyzed eight classes of tapered-fiber forms: fiber Bragg grating (FBG), long-period fiber grating (LPFG), Mach–Zehnder interferometer (MZI), photonic crystals fiber (PCF), surface plasmonic resonance (SPR), multi-taper devices, fiber loop ring-down technology, and optical tweezers. We evaluated many issues to make an informed judgement about the viability of employing the best of these methods in optical sensors. The analysis of performance for tapered optical fibers depends on four mean parameters: taper length, sensitivity, wavelength scale, and waist diameter. Finally, we assess the most potent strategy that has the potential for medical and environmental applications.
- 27 July 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (8) , 253
Open AccessComprehensive Review Tapered Optical Fiber Configurations for Sensing Application: Trend and Challenges
Understanding environmental information is necessary for functions correlated with human activities to improve healthcare quality and reduce ecological risk. Tapered optical fibers reduce some limitations of such devices and can be considerably more responsive to fluorescence and absorption properties changes. Data have been collected from reliable sources such as Science Direct, IEEE Xplore, Scopus, Web of Science, PubMed, and Google Scholar. In this narrative review, we have summarized and analyzed eight classes of tapered-fiber forms: fiber Bragg grating (FBG), long-period fiber grating (LPFG), Mach–Zehnder interferometer (MZI), photonic crystals fiber (PCF), surface plasmonic resonance (SPR), multi-taper devices, fiber loop ring-down technology, and optical tweezers. We evaluated many issues to make an informed judgement about the viability of employing the best of these methods in optical sensors. The analysis of performance for tapered optical fibers depends on four mean parameters: taper length, sensitivity, wavelength scale, and waist diameter. Finally, we assess the most potent strategy that has the potential for medical and environmental applications.