Jakub Buday
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jakub Buday has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Jozef Kaiser
Central European Institute of Technology, Brno University of Technology, 61200 Brno, Czech Republic
8 shared publications - Pavel Pořízka
Brno University of Technology
8 shared publications - Anna Faruzelová
CEITEC Brno University of Technology, Purkyňova 656/123, 61200 Brno, Czech Republic
2 shared publications - Daniel Holub
Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, Brno, Czech Republic
2 shared publications - David Prochazka
Central European Institute of Technology, Brno University of Technology, Purkynova 656/123, 61200 Brno, Czech Republic
2 shared publications - Hana KopřIvová
Central European Institute of Technology (CEITEC), Brno University of Technology, Purkyňova 123, 612 00 Brno, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1428
Towards cross-instrument LIBS calibration for rare earth element analysis
- 26 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1428
Open AccessTowards cross-instrument LIBS calibration for rare earth element analysis
- Open Access
- 4 September 2026
- Published by Springer Nature in Scientific Data
Regolith simulant dataset for terrestrial and simulated extraterrestrial conditions using LIBS
- 4 September 2026
- Published by Springer Nature in Scientific Data
Open AccessRegolith simulant dataset for terrestrial and simulated extraterrestrial conditions using LIBS
- Open Access
- 7 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1663-1674
A comparative study of nanosecond laser wavelengths for improved LIBS analysis of soft tissues
Nd:YAG ablation laser (1064, 532 and 266 nm) comparative performance study on soft biological tissues. Performance of LIBS for spatially resolved analysis.
- 7 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1663-1674
Open AccessA comparative study of nanosecond laser wavelengths for improved LIBS analysis of soft tissues
Nd:YAG ablation laser (1064, 532 and 266 nm) comparative performance study on soft biological tissues. Performance of LIBS for spatially resolved analysis.
- Open Access
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 593-600
Many-to-many transfer of LIBS spectra across multiple experimental conditions
A single machine learning model enabling many-to-many LIBS spectral transfer across multiple conditions without extensive calibration or paired data.
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 593-600
Open AccessMany-to-many transfer of LIBS spectra across multiple experimental conditions
A single machine learning model enabling many-to-many LIBS spectral transfer across multiple conditions without extensive calibration or paired data.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 9951057
Comparative Assessment of Five Decalcification Methods for Human Dental Tissue: An Ex Vivo Laboratory Study
Background: Histological examination of human teeth is essential for the diagnosis of developmental anomalies, odontogenic lesions, and other dental pathologies. However it remains technically challenging because highly mineralized tissues require extensive processing before thin sections suitable for microscopic evaluation can be obtained. This study aimed to identify a decalcification protocol suitable for routine dental pathology by balancing rapid processing with high‐quality tissue preservation. To achieve this, we compared five commonly used decalcification protocols using complementary histological and spectroscopic analyses. Methods: Forty‐nine human teeth were decalcified using one of the five investigated agents: HNO 3 , HCOOH, DC1, Microdecfast, or Löwy’s solution. Decalcification speed, sectioning quality, and histological staining characteristics (H&E, PAS, Gömöri, and von Kossa) were evaluated. Laser‐induced breakdown spectroscopy (LIBS) was used for spectral analysis, 2D elemental mapping, and semi‐quantitative assessment of Ca, Mg, P, and C, enabling direct comparison of demineralization efficiency and spatial homogeneity across agents. Results: Decalcification efficiency differed markedly among the tested agents. HNO 3 provided the fastest and most consistent tissue softening, whereas Löwy’s solution was the slowest and often failed to achieve complete decalcification. LIBS demonstrated that HNO 3 and DC1 produced the most homogeneous depletion of Ca, Mg, and P, while Microdecfast and HCOOH resulted in less uniform mineral removal. All decalcifying agents depleted mineral elements beyond calcium, indicating that some protocols (HNO 3 and DC1) may be unsuitable for studies requiring preservation of the native elemental composition. Less homogeneous demineralization was associated with harder tissues, inferior sectioning quality, and increased sample fragmentation. Conclusions: By integrating histology with LIBS analysis, this study demonstrates that decalcifying agents differ substantially in their decalcification speed, tissue preservation, and mineral removal profiles. Notably, 5% HNO 3 emerged as the most efficient agent, enabling rapid decalcification with preserved staining quality and homogeneous mineral depletion. These findings provide practical guidance for diagnostic histopathology laboratories by facilitating faster processing of dental specimens while maintaining the tissue quality required for accurate microscopic diagnosis.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 9951057
Open AccessComparative Assessment of Five Decalcification Methods for Human Dental Tissue: An Ex Vivo Laboratory Study
Background: Histological examination of human teeth is essential for the diagnosis of developmental anomalies, odontogenic lesions, and other dental pathologies. However it remains technically challenging because highly mineralized tissues require extensive processing before thin sections suitable for microscopic evaluation can be obtained. This study aimed to identify a decalcification protocol suitable for routine dental pathology by balancing rapid processing with high‐quality tissue preservation. To achieve this, we compared five commonly used decalcification protocols using complementary histological and spectroscopic analyses. Methods: Forty‐nine human teeth were decalcified using one of the five investigated agents: HNO 3 , HCOOH, DC1, Microdecfast, or Löwy’s solution. Decalcification speed, sectioning quality, and histological staining characteristics (H&E, PAS, Gömöri, and von Kossa) were evaluated. Laser‐induced breakdown spectroscopy (LIBS) was used for spectral analysis, 2D elemental mapping, and semi‐quantitative assessment of Ca, Mg, P, and C, enabling direct comparison of demineralization efficiency and spatial homogeneity across agents. Results: Decalcification efficiency differed markedly among the tested agents. HNO 3 provided the fastest and most consistent tissue softening, whereas Löwy’s solution was the slowest and often failed to achieve complete decalcification. LIBS demonstrated that HNO 3 and DC1 produced the most homogeneous depletion of Ca, Mg, and P, while Microdecfast and HCOOH resulted in less uniform mineral removal. All decalcifying agents depleted mineral elements beyond calcium, indicating that some protocols (HNO 3 and DC1) may be unsuitable for studies requiring preservation of the native elemental composition. Less homogeneous demineralization was associated with harder tissues, inferior sectioning quality, and increased sample fragmentation. Conclusions: By integrating histology with LIBS analysis, this study demonstrates that decalcifying agents differ substantially in their decalcification speed, tissue preservation, and mineral removal profiles. Notably, 5% HNO 3 emerged as the most efficient agent, enabling rapid decalcification with preserved staining quality and homogeneous mineral depletion. These findings provide practical guidance for diagnostic histopathology laboratories by facilitating faster processing of dental specimens while maintaining the tissue quality required for accurate microscopic diagnosis.
- Open Access
- 1 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (9) , 2426-2437
Influence of sample matrix and filter fixation on LIBS signal in analysis of algae on filter
This study first reveals the matrix effect mechanism of filter fixation on laser-induced breakdown spectroscopy (LIBS) quantitative analysis of algae, providing a methodological reference for in situ environmental detection.
- 1 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (9) , 2426-2437
Open AccessInfluence of sample matrix and filter fixation on LIBS signal in analysis of algae on filter
This study first reveals the matrix effect mechanism of filter fixation on laser-induced breakdown spectroscopy (LIBS) quantitative analysis of algae, providing a methodological reference for in situ environmental detection.
- Open Access
- 4 September 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (10) , 2461-2470
Statistical behaviour of laser-induced plasma and its complementary characteristic signals
In this work, we present a study aimed at the statistical distribution of characteristic signals of laser-induced plasmas. This work mainly focuses on observing statistical distribution for repetitive measurement of spectra, plasma plume imaging, and sound intensity. These were captured by using various laser irradiances, spanning between 1.72 and 6.25 GW cm−2 for a 266 nm laser. Their distributions were fitted by Gaussian, generalized extreme value (GEV), and Burr distributions, as typical representation models used in LIBS. These were compared using the Kolmogorov–Smirnov (KS) test by its null hypothesis on whether these models are suitable or fail to describe the statistical distribution of the data. The behavior of the data distribution has shown a certain connection to the plasma plume temperature. This was observed for all the used ablation energies. Performances of the statistical models were further compared in the outlier filtering process, where the relative standard deviation of the filtered data was observed. The results presented in this work suggest that an appropriate selection of a statistical model for the data representation can lead to an improvement in the LIBS performance.
- 4 September 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (10) , 2461-2470
Open AccessStatistical behaviour of laser-induced plasma and its complementary characteristic signals
In this work, we present a study aimed at the statistical distribution of characteristic signals of laser-induced plasmas. This work mainly focuses on observing statistical distribution for repetitive measurement of spectra, plasma plume imaging, and sound intensity. These were captured by using various laser irradiances, spanning between 1.72 and 6.25 GW cm−2 for a 266 nm laser. Their distributions were fitted by Gaussian, generalized extreme value (GEV), and Burr distributions, as typical representation models used in LIBS. These were compared using the Kolmogorov–Smirnov (KS) test by its null hypothesis on whether these models are suitable or fail to describe the statistical distribution of the data. The behavior of the data distribution has shown a certain connection to the plasma plume temperature. This was observed for all the used ablation energies. Performances of the statistical models were further compared in the outlier filtering process, where the relative standard deviation of the filtered data was observed. The results presented in this work suggest that an appropriate selection of a statistical model for the data representation can lead to an improvement in the LIBS performance.
- Open Access
- 5 August 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (9) , 2330-2339
Investigating the effects of laser wavelengths and other ablation parameters on the detection of biogenic elements and contaminants in hydroxyapatite
A comparison of laser ablation measurement parameters (laser wavelength, energy, gate delay, defocus, and spot size) to determine optimal settings for the detection of heavy metals and biogenic elements in a hard tissue matrix (hydroxyapatite).
- 5 August 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (9) , 2330-2339
Open AccessInvestigating the effects of laser wavelengths and other ablation parameters on the detection of biogenic elements and contaminants in hydroxyapatite
A comparison of laser ablation measurement parameters (laser wavelength, energy, gate delay, defocus, and spot size) to determine optimal settings for the detection of heavy metals and biogenic elements in a hard tissue matrix (hydroxyapatite).
- Open Access
- 3 May 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1310, 342663
Imaging the elemental distribution within human malignant melanomas using Laser-Induced Breakdown Spectroscopy
- 3 May 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1310, 342663
Open AccessImaging the elemental distribution within human malignant melanomas using Laser-Induced Breakdown Spectroscopy
- 27 February 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1299, 342418
Comparison of single and double pulse laser-induced breakdown spectroscopy for the detection of biomolecules tagged with photon-upconversion nanoparticles
- 27 February 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1299, 342418
Comparison of single and double pulse laser-induced breakdown spectroscopy for the detection of biomolecules tagged with photon-upconversion nanoparticles