Manish Pandit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manish Pandit has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Ranjana Sodhi
Department of Electrical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
3 shared publications Ranjana Sodhi
1 shared publication- Sourav De
Department of Electrical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
1 shared publication
Latest Publications
- 10 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
PMU measurements enabled real-time adaptive load modeling framework
- 10 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
PMU measurements enabled real-time adaptive load modeling framework
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Knowledge and Data Engineering
- Vol. 37 (5) , 2488-2500
Efficient PMU Data Compression Using Enhanced Graph Filtering Enabled Principal Component Analysis
Phasor Measurement Units (PMUs) are state-of-the-art measuring devices that capture high-resolution time-synchronized voltage and current phasor measurements in wide area monitoring systems (WAMS). Their usage for various real-time applications demands a huge amount of data collected from multiple PMUs to be transmitted from the local phasor data concentrator (PDC) to the control centre. To optimize the requirements of bandwidth to transmit the data as well as to store the data, an efficient synchrophasor data compression technique is desired. To this end, this paper presents a 3-stage data compression scheme in which Stage-1 performs the accumulation of the data matrix from the optimally placed PMUs in WAMS into the local PDC. The data is then passed through a novel Ramanujan's sum-based fault window detection algorithm to identify the fault within the PMU data matrix in Stage-2. Finally, Stage-3 proposes an enhanced graph filtering-enabled principal component analysis scheme which expands the notion of conventional PCA techniques into the graph domain to compress the data. The performance of the proposed scheme is verified on the IEEE 14-bus system and New England 39-bus system. Further, practical applicability of the proposed method is validated on field PMU data collected from EPFL campus in Switzerland.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Knowledge and Data Engineering
- Vol. 37 (5) , 2488-2500
Efficient PMU Data Compression Using Enhanced Graph Filtering Enabled Principal Component Analysis
Phasor Measurement Units (PMUs) are state-of-the-art measuring devices that capture high-resolution time-synchronized voltage and current phasor measurements in wide area monitoring systems (WAMS). Their usage for various real-time applications demands a huge amount of data collected from multiple PMUs to be transmitted from the local phasor data concentrator (PDC) to the control centre. To optimize the requirements of bandwidth to transmit the data as well as to store the data, an efficient synchrophasor data compression technique is desired. To this end, this paper presents a 3-stage data compression scheme in which Stage-1 performs the accumulation of the data matrix from the optimally placed PMUs in WAMS into the local PDC. The data is then passed through a novel Ramanujan's sum-based fault window detection algorithm to identify the fault within the PMU data matrix in Stage-2. Finally, Stage-3 proposes an enhanced graph filtering-enabled principal component analysis scheme which expands the notion of conventional PCA techniques into the graph domain to compress the data. The performance of the proposed scheme is verified on the IEEE 14-bus system and New England 39-bus system. Further, practical applicability of the proposed method is validated on field PMU data collected from EPFL campus in Switzerland.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6523-6531
Phasor Measurement Sensor-Assisted Time-to-Collapse Estimation Under Long-Term Voltage Instability of Smart Grids
The synchrophasor measurement sensors are the state-of-the-art measuring devices available in the modern Smart grids (SGs), which are capable of providing fast and accurate phasor measurements in the system. This phasor information has been exploited in this paper to develop a model-free technique to accurately assess the long term voltage stability of the system. The proposal first makes the system observable with minimum number of sensors, and the phasor measurements obtained from these optimal number of sensors are then utilized in the regression theorem of Ornstein Uhlenbeck process to assemble a scaled Jacobian in real-time. After carrying out the modal analysis on the measurement based Jacobian, two novel stability indices are proposed. The performance of the proposed technique is tested on the benchmark IEEE 14-bus and the New England 39-bus system under various scenarios like dynamic load increase under base conditions, critical line outage, critical generator outage, etc. The efficacy of the proposed method is also accredited by its real time implementation using Real Time Digital Simulator (RTDS). The results demonstrate that the proposed method achieves an accurate and an early prediction of the emanating system collapse conditions while exploiting information from the minimum number of sensors in the field.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6523-6531
Phasor Measurement Sensor-Assisted Time-to-Collapse Estimation Under Long-Term Voltage Instability of Smart Grids
The synchrophasor measurement sensors are the state-of-the-art measuring devices available in the modern Smart grids (SGs), which are capable of providing fast and accurate phasor measurements in the system. This phasor information has been exploited in this paper to develop a model-free technique to accurately assess the long term voltage stability of the system. The proposal first makes the system observable with minimum number of sensors, and the phasor measurements obtained from these optimal number of sensors are then utilized in the regression theorem of Ornstein Uhlenbeck process to assemble a scaled Jacobian in real-time. After carrying out the modal analysis on the measurement based Jacobian, two novel stability indices are proposed. The performance of the proposed technique is tested on the benchmark IEEE 14-bus and the New England 39-bus system under various scenarios like dynamic load increase under base conditions, critical line outage, critical generator outage, etc. The efficacy of the proposed method is also accredited by its real time implementation using Real Time Digital Simulator (RTDS). The results demonstrate that the proposed method achieves an accurate and an early prediction of the emanating system collapse conditions while exploiting information from the minimum number of sensors in the field.