JWJipson Hon Fai Wong

Jipson Hon Fai Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jipson Hon Fai Wong has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Corneal Sensitivity: Tools We Have

    by Ezra Eio, Mingyi Yu, Chang Liu, Isabelle Xin Yu Lee, Regina Kay Ting Wong, Jipson Hon Fai Wong, Yu-Chi Liu

    Corneal sensitivity is an important indicator of corneal health and innervation. Corneal hypoesthesia may be an early indicator of corneal diseases such as neurotrophic keratopathy. Various instruments have been used to measure corneal sensitivity, the first being the Cochet–Bonnet aesthesiometer. Over the years, new devices employing different stimuli have been developed, such as the gas-based Belmonte aesthesiometer, the Swiss liquid-jet aesthesiometer, and the most recently released corneal Brill aesthesiometer. In this review, the progress and advancement of aesthesiometers since their introduction is described. The mechanism, advantages, and disadvantages of these aesthesiometers are discussed and compared. We also report the relationship between corneal sensitivity and corneal innervation in various conditions, including diabetes mellitus, Fuchs’ endothelial dystrophy, dry eye disease, glaucoma, keratoconus, herpes simplex keratitis, post-refractive surgery, and ocular graft-versus-host disease. Through this review, we aim to highlight the importance of the assessment of corneal sensitivity and innervation in the diagnosis, treatment, and monitoring of anterior and posterior segment ocular disorders.


  • Open Access

    Quality of Life and Symptomatology in Neuropathic Corneal Pain in Comparison With Dry Eye Syndrome

    by Jia Ying Chin, Louis Tong, Chang Liu, Isabelle Xin Yu Lee, Jipson Hon Fai Wong, Regina Kay Ting Wong, Jodhbir S. Mehta, Yu-Chi Liu

    Purpose: To investigate and compare the quality of life (QoL) and symptomatology between neuropathic corneal pain (NCP) and dry eye disease (DED). Methods: We recruited 150 patients, comprising 50 patients with NCP and 100 patients with DED. Patients’ symptoms and QoL were evaluated using the Ocular Pain Assessment Survey and Ocular Surface Disease Index questionnaires. Ocular surface assessments were also performed. Results: Patients with NCP demonstrated significantly lower Oxford and National Eye Institute scores for ocular surface and corneal staining, respectively, and a better tear break-up time than patients with DED. However, patients with NCP reported significantly worse scores on most of the Ocular Pain Assessment Survey questions and significantly more severe overall pain (P = 0.019), maximal and average ocular pain and nonocular pain (all P < 0.05). The NCP group reported significantly worse QoL in all aspects of daily living (all P < 0.001). Patients with NCP spent more time thinking about their eye pain and reported significantly higher pain intensities than patients with DED when exposed to chemical and mechanical stimuli (all P ≤ 0.008). Burning sensation and photophobia were significantly more frequent in patients with NCP (P = 0.032 and P = 0.012, respectively). Similarly, the NCP group reported significantly worse total Ocular Surface Disease Index scores, significantly more frequent vision-related function impairment and painful or sore eyes than the DED group (P = 0.029, P = 0.031, and P = 0.014, respectively). Conclusions: Compared with DED, NCP is more debilitating, leading to more severe and frequent symptoms, and greater negative impact on all aspects of QoL.


  • Open Access

    Impact of Age on the Characteristics of Corneal Nerves and Corneal Epithelial Cells in Healthy Adults

    by Jia Ying MBChB Chin, Chang Bsc Liu, Isabelle Xin Yu Bsc Lee, Molly Tzu Yu Msc Lin, Ching-Yu Cheng, Jipson Hon Fai Dip Wong, Cong Ling Bsc Teo, Jodhbir S. PhD Mehta, Yu-Chi Md Liu

    Purpose: The aim of this study was to investigate age-related changes in corneal nerves and corneal epithelial cell parameters and to establish age-adjusted reference values. Methods: A total of 7025 corneal nerve images and 4215 corneal epithelial images obtained using in vivo confocal microscopy from 281 eyes of 143 healthy participants were included. Seven corneal nerve parameters and 3 corneal epithelial cell parameters were quantified using 2 automatic analytic software and analyzed across 6 age groups ranging from 21 to 80 years. Results: There was a declining trend in all 7 nerve parameters with advancing age. In particular, corneal nerve fiber length and corneal nerve fiber density demonstrated a significant decrease in subjects aged 65 years or older compared with subjects younger than 65 years (10.8 ± 2.6 mm/mm2 vs. 9.9 ± 2.0 mm/mm2, P = 0.011 in corneal nerve fiber length; 15.8 ± 5.2 fibers/mm2 vs. 14.4 ± 4.3 fibers/mm2, P = 0.046 in corneal nerve fiber density), whereas corneal nerve fractal dimension demonstrated a borderline significant decrease (P = 0.057). Similarly, there was a general declining trend in all epithelial cell parameters with advancing age. Corneal epithelial cell circularity was significantly lower in subjects aged 65 years and older as compared to subjects younger than 65 years (0.722 ± 0.021 μm2 vs. 0.714 ± 0.021 μm2; P = 0.011). Conclusions: Advancing age results in reduced corneal nerve metrics and alteration of corneal cell morphology. Aging effects should be considered when evaluating patients with corneal neuropathy.