AOAna Luísa Botta Martins de Oliveira

Ana Luísa Botta Martins de Oliveira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ana Luísa Botta Martins de Oliveira has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Color stability of dental enamel bleached with violet LED associated with or without Low concentration peroxide gels

    by Bianca Matos Fernandes, Marcia Hiromi Tanaka, Ana Luisa Botta Martins De Oliveira, Renata Siqueira Scatolin


  • Open Access

    Effect of finishing and polishing on color stability of a nanofilled resin immersed in different media

    by Ana Luísa Botta Martins de Oliveira, Camila Cruz Lorenzetti, Patrícia Petromilli Nordi Sasso Garcia, Elisa Maria Aparecida Giro

    OBJECTIVE: The purpose of this study was to evaluate the effect of finishing and polishing on color stability of a nanofilled composite resin (Filtek Z350 XT) according to different immersion media.MATERIAL AND METHOD: Composite disks (10 mm diameter, 2 mm thickness) were prepared for each group (n = 6) using a stainless steel mold. The groups were divided according to the presence or absence of finishing and polishing procedure and immersion media (artificial saliva, artificial juice- KAPO(r) Coca-Cola(r)flavors: pineapple, orange, strawberry and grape). The finishing and polishing procedures were performed using Super -Snap(r) disks. The specimens were stored in artificial saliva for 24 hours (baseline) and were analyzed using a color spectrophotometer by CIELab system. Then, they were immersed in different media for 5 minutes, 3 times a day, every 4 hours during 60 days. They were stored in artificial saliva at 37 ± 1°C during the immersion intervals. After this time, new measure of color was performed. The data were analyzed using Kruskall-Wallis test and Mann- Whitney test. The significance level was 5%.RESULT: The results showed that the finishing/polishing not significantly influence the color stability of resin composite (p > 0.05). There was no statistically significant difference in the color stability of the studied resin after immersion in different media (p > 0.05).CONCLUSION: The finishing and polishing procedures and the immersion media did not have influence on color stability of nanofilled resin Filtek Z350 XT.


  • Influence of light curing units and fluoride mouthrinse on morphological surface and color stability of a nanofilled composite resin

    by Ana Luísa Botta Martins De Oliveira, Ana Carolina Botta, Juliana Álvares Duarte Bonini Campos, Patrícia Petromilli Nordi Sasso Garcia

    Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution‐manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24‐h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two‐way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. Microsc. Res. Tech. 77:941–946, 2014.


  • Roughness and Morphology of Composites: Influence of Type of Material, Fluoride Solution, and Time

    by Ana Luísa Botta Martins de Oliveira, Elisa Maria Aparecida Giro, Patrícia Petromilli Nordi Sasso Garcia, Juliana Álvares Duarte Bonini Campos, Jin-Ho Phark, Sillas Duarte

    This study evaluated the effect of fluoride solutions on surface roughness and morphology of composites in the short and long term. Specimens were randomly assigned to experimental groups (n=5) according to type of composite (nanofilled, microhybrid, microfilled) and immersion media (artificial saliva, 0.05% sodium fluoride solution, Fluordent Reach, Oral-B, and Fluorgard). Roughness was evaluated at time intervals: T0 after 24 h in artificial saliva (baseline); T60 after being in assigned immersion media for 1 min daily over 60 days; and Tfinal after artificial aging (20,000 thermal cycles, 1,200,000 mechanical loading cycles, and continuous immersion for 1,825 min). Surface morphology was qualitatively analyzed by scanning electron microscopy (SEM) at T60 and Tfinal. Roughness data were submitted to analysis of variance for mixed repeated measures, Sidak, and Tukey tests at α=0.05. Micro-filled resin showed the highest roughness values. Fluoride solutions had no influence on roughness. Higher roughness values were observed after artificial aging. In SEM observations after the artificial aging, the specimens showed surface degradation, irrespective of immersion medium or type of composite. Nano-filled resin showed higher loss of resin matrix and protrusion of filler particles. Roughness was not influenced by fluoride solutions; however, it is material dependent and increases over time.


  • Effects of Immersion Media and Repolishing on Color Stability and Superficial Morphology of Nanofilled Composite Resin

    by Ana Luísa Botta Martins de Oliveira, Ana Carolina Botta, Juliana Álvares Duarte Bonini Campos, Patrícia Petromilli Nordi Sasso Garcia

    This study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro–Wilk test (p>0.05 for the different immersion media) and Sidak’s test (pE values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.


  • Open Access

    COLOR STABILITY OF A NANOFILLED RESIN: INFLUENCE OF POLISHING AND FINISHING AND FLUORIDE SOLUTIONS ACCORDING TO TIME

    by Ana Luísa Botta Martins Oliveira, Patrícia Aleixo dos Santos Domingos, Juliana Alvares Duarte Bonini Campos, Ana Carolina Botta, Patrícia Petromilli Nordi Sasso Garcia

    AIM: The aim of the study was evaluate the finishing and polishing effect of the color stability of the composite resin Filtek Supreme XT, according to different fluoride solutions and time. MATERIAL AND METHODS: Specimens were prepared (n=140) with half of the samples finished and polished. The experimental groups were divided according to the presence or absence of finishing and polishing and immersion solutions (artificial saliva, sodium fluoride solution at 0.05% - manipulated, Fluordent Reach, Oral B, Fluorgard). The specimens remained in artificial saliva for 24 hours and were subjected to an initial color analysis using a spectrophotometer CIELab system. Then, they were immersed in the experimental solutions for 1 minute a day. The readings of the color change were made after 24 and 48 hours, 7, 14, 21, 30 and 60 days after the first immersion. The three-way mixed Analysis of Variance (ANOVA) ("finishing/polishing", "immersion medium" and “time”) were performed. For multiple comparisons, the Sidak test for repeated measure was used, with a 5% level of significance. RESULTS: The finishing and polishing factor showed significant variability, independently of the immersion media (pCONCLUSION: Finishing and polishing procedures yielded better color stability to composite resin over time, regardless of the immersion media.


  • Chemical and morphological features of nanofilled composite resin: Influence of finishing and polishing procedures and fluoride solutions

    by Ana Luísa Botta Martins de Oliveira, Patrícia Aleixo Dos Santos Domingos, Regina Guenka Palma‐Dibb, Patrícia Petromilli Nordi Sasso Garcia

    This study evaluated the influence of finishing and polishing procedures and different fluoride solutions on superficial morphology and chemistry of the nanofilled composite resin Supreme XT (3M) through the EDX analysis and SEM evaluation. Circular specimens (n= 30) of 10 mm diameter and 2 mm thickness were prepared, with half of the sample assays finished and polished with Super‐Snap® sandpaper. The experimental groups were divided according to the presence or absence of finishing and polishing and solutions (artificial saliva, 0.05% of manipulated sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were immersed in each respective solution for 1 min per day, during 60 days and stored in artificial saliva at 37 ± 1°C between immersion periods. Topography and chemical analysis was qualitative. It was observed that specimens submitted to finishing and polishing procedures had lower superficial degradation. Fluoride solutions promoted superficial alterations on specimens, being the highest degradation obtained with Fluordent Reach. It can be concluded that finishing and polishing procedures and the immersion media influence the superficial morphology of composite resin tested; the Fluordent Reach was the fluoride solution that most affected the material's surface. Microsc. Res. Tech. 2011.,


  • Open Access

    ABORDAGEM MULTIDISCILINAR NO TRATAMENTO DO BRUXISMO INFANTIL

    by Ana Luísa Botta Martins Oliveira, Camila Fragelli, Marcelo Ferrarezi Andrade

    O conhecimento dos fatores etiológicos e das características clínicas do bruxismo na infância é fundamental para que o diagnóstico seja precoce, permitindo o estabelecimento de um tratamento multidisciplinar e favorecendo o desenvolvimento integral da criança para a promoção de saúde e qualidade de vida. Desta maneira, o presente trabalho objetivou através de revisão da literatura, abordar os fatores etiológicos, as características clínicas, os sinais e sintomas, a importância do diagnóstico e as terapêuticas disponíveis para o tratamento do bruxismo em crianças. De acordo com a literatura analisada observou-se que o bruxismo é um hábito parafuncional, com alta prevalência em crianças e que apresenta uma somatória de fatores que envolvem a sua etiologia. Tendo em vista as importantes repercussões do bruxismo no sistema estomatognático, seu tratamento torna-se complexo devido a sua etiologia multifatorial, a qual deve ser considerada no planejamento do tratamento com abordagem multidisciplinar