Felipe Leiva-Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felipe Leiva-Silva has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Juan Carlos Travieso-Torres
University of Santiago Chile, Santiago, Chile
4 shared publications - Abdiel Ricaldi-Morales
Universidad de Chile, Santiago, Chile
3 shared publications - Adolfo Véliz-Tejo
Department of Electrical Engineering, Universidad Técnica Federico Santa María, San Joaquín, Chile
3 shared publications - Andrés Mora
Department of Electrical Engineering, Universidad Tcnica Federico Santa Mara, Valparaiso, Chile
1 shared publication - Felix Rojas
Department of Electrical Engineering, Pontificia Universidad Catlica de Chile, Santiago, Chile
1 shared publication - Javier Pereda
Department of Electrical Engineering, Pontificia Universidad Catlica de Chile, Santiago, Chile
1 shared publication
Latest Publications
- 25 April 2024
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 112 (12) , 10081-10093
Taylor series and adaptive passivity-based control for conical tanks level regulation
- 25 April 2024
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 112 (12) , 10081-10093
Taylor series and adaptive passivity-based control for conical tanks level regulation
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 13890-13900
Self-Commissioning Parameter Estimation Algorithm for Loaded Induction Motors
Induction motor (IM) drive systems are pivotal in modern industrial and commercial applications, driving essential processes and systems across various sectors efficiently and reliably. The accurate estimation of IM and load parameters is challenging but vital to guarantee the optimal performance of the entire drive system. The IEEE Standard 112A and existing online methods take hours to estimate only IM parameters after shutting down, disconnecting, estimating, reconnecting, and realigning the motor and its load using specialized tools. Offline techniques assume a known IM manufacturer datasheet, which is often unavailable. Therefore, this article proposes a novel online self-commissioning algorithm that estimates the parameters of an IM and its load in a remarkably swift time frame of just 180 s without disconnecting the IM from the load or using the IM manufacturer datasheet. The proposed method only requires the IM nameplate information and employs a discrete normalized model reference adaptive system. In addition, its computational burden is minimal, making it suitable for practical real-time implementation using the commercial and cost-effective microcontroller for power electronics, i.e., c2000 TMS320F28388D control platform. Comprehensive experimental results for fan-type loads driven by 1.1- and 7.5-kW IMs are discussed to validate the proposal.
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 13890-13900
Self-Commissioning Parameter Estimation Algorithm for Loaded Induction Motors
Induction motor (IM) drive systems are pivotal in modern industrial and commercial applications, driving essential processes and systems across various sectors efficiently and reliably. The accurate estimation of IM and load parameters is challenging but vital to guarantee the optimal performance of the entire drive system. The IEEE Standard 112A and existing online methods take hours to estimate only IM parameters after shutting down, disconnecting, estimating, reconnecting, and realigning the motor and its load using specialized tools. Offline techniques assume a known IM manufacturer datasheet, which is often unavailable. Therefore, this article proposes a novel online self-commissioning algorithm that estimates the parameters of an IM and its load in a remarkably swift time frame of just 180 s without disconnecting the IM from the load or using the IM manufacturer datasheet. The proposed method only requires the IM nameplate information and employs a discrete normalized model reference adaptive system. In addition, its computational burden is minimal, making it suitable for practical real-time implementation using the commercial and cost-effective microcontroller for power electronics, i.e., c2000 TMS320F28388D control platform. Comprehensive experimental results for fan-type loads driven by 1.1- and 7.5-kW IMs are discussed to validate the proposal.
- Open Access
Robust Cascade MRAC for a Hybrid Grid-Connected Renewable Energy System
Hybrid grid-connected renewable energy systems have gained significant importance in sustainably responding to an increased electrical energy demand. These are time-varying nonlinear dynamical plants, where the value of their parameters depends on changing weather conditions and the alternating grid voltage with randomly fluctuating amplitude. This paper proposes a robust cascade MRAC for nonlinear plants representing a class of these systems, which includes n renewable energy converts and a DC/AC single-phase full bridge inverter. The proposal reduces commissioning time by avoiding linearization and knowledge of the plant parameters. Moreover, it includes specific formulas for tuning the controller parameters that decrease their adjustments based on trial and error. Finally, it uses a direct adaptive method with adaptive laws having modification and an inner loop at least five times faster than the outer loop. The proposition validation includes the theoretical stability proof based on the Lyapunov stability method and Barbalat’s Lemma. Furthermore, it presents comparative simulation results with quoted cascade PI controllers for a monophasic system, including two renewable energy sources and injection. Both techniques effectively track setpoint changes of the energy sources’ currents and direct current bus voltage, showing the proposal similar or reduced ripple. At the same time, both ensure robustness against decreased photovoltage panels irradiance, increased fuel cells voltage, and grid voltage amplitude random fluctuations. However, the proposal does these things while avoiding prior linearization and unknowing the plant parameters.Open AccessRobust Cascade MRAC for a Hybrid Grid-Connected Renewable Energy System
Hybrid grid-connected renewable energy systems have gained significant importance in sustainably responding to an increased electrical energy demand. These are time-varying nonlinear dynamical plants, where the value of their parameters depends on changing weather conditions and the alternating grid voltage with randomly fluctuating amplitude. This paper proposes a robust cascade MRAC for nonlinear plants representing a class of these systems, which includes n renewable energy converts and a DC/AC single-phase full bridge inverter. The proposal reduces commissioning time by avoiding linearization and knowledge of the plant parameters. Moreover, it includes specific formulas for tuning the controller parameters that decrease their adjustments based on trial and error. Finally, it uses a direct adaptive method with adaptive laws having modification and an inner loop at least five times faster than the outer loop. The proposition validation includes the theoretical stability proof based on the Lyapunov stability method and Barbalat’s Lemma. Furthermore, it presents comparative simulation results with quoted cascade PI controllers for a monophasic system, including two renewable energy sources and injection. Both techniques effectively track setpoint changes of the energy sources’ currents and direct current bus voltage, showing the proposal similar or reduced ripple. At the same time, both ensure robustness against decreased photovoltage panels irradiance, increased fuel cells voltage, and grid voltage amplitude random fluctuations. However, the proposal does these things while avoiding prior linearization and unknowing the plant parameters. - 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 1271-1281
Optimal Switching Sequence MPC for Four-Leg Two-Level Grid-Connected Converters
This paper presents a versatile and effective model predictive current control strategy based on optimal switching sequences for four–leg two–level grid–connected converters. The proposed control methodology, presents an excellent dynamic performance, good tracking of high-frequency reference signals, fixed switching frequency, and well-formed harmonic spectrum, enabling the proposed controller to govern shunt active filters and distributed generation applications based on four-leg converters. Experimental results demonstrate the effectiveness and high-quality performance obtained with the proposed strategy.
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 1271-1281
Optimal Switching Sequence MPC for Four-Leg Two-Level Grid-Connected Converters
This paper presents a versatile and effective model predictive current control strategy based on optimal switching sequences for four–leg two–level grid–connected converters. The proposed control methodology, presents an excellent dynamic performance, good tracking of high-frequency reference signals, fixed switching frequency, and well-formed harmonic spectrum, enabling the proposed controller to govern shunt active filters and distributed generation applications based on four-leg converters. Experimental results demonstrate the effectiveness and high-quality performance obtained with the proposed strategy.