Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengliang Fan has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Causes of PM 2.5 pollution in the atmospheric environment, health risks and economic losses in different geographical administrative regions

    by Yongbo Cui, Huihui He, Xiaoqing Zhou, Chengliang Fan

    PM 2.5 has become a major pollutant in the atmospheric environment, posing a serious threat to people's health and seriously hindering the sustainable development of urban environments. However, there is still limited assessment of the health risks and economic losses associated with PM 2.5 pollution in megacities. Therefore, this study systematically analysed the spatiotemporal distribution characteristics, health risks and economic losses associated with PM 2.5 concentrations in seven typical Chinese cities. The results show a typical ‘bimodal’ structure with fluctuations up to 10–12 μg/m 3 throughout the day in the northern cities. Fluctuations are only 2–3 μg/m 3 throughout the day in southern cities. Seasonal differences in PM 2.5 concentrations are regular, showing an overall trend of winter > spring > autumn > summer. The distribution of PM 2.5 concentrations in different cities shows that PM 2.5 tends to accumulate in areas with high population density, high traffic density, high energy consumption and high heating emissions. PM 2.5 pollution causes an average of more than 50 premature deaths per million people per year in different cities. In addition, economic losses due to PM 2.5 pollution average more than 1.28 × 10 6 per year. PM 2.5 is inversely proportional to temperature and humidity concentrations, and has a significant positive correlation relationship with PM 10 , SO 2 , CO and NO 2 .

  • Open Access

    Heat Risk Assessment and Mitigation Strategies for Old Residential Communities

    by Lisi Kuang, Lan Yang, Chengliang Fan

    Old residential communities, characterized by dense built environments, high levels of population aging, and insufficient public services, represent critical hotspots of urban heat risk. Taking old residential communities in the central urban area of Guangzhou as the study area, this study integrates multi-source data, including social, economic, and urban infrastructure information, to develop a heat risk assessment framework encompassing four dimensions: heat hazard, heat exposure, heat vulnerability, and heat adaptation. The model is validated using data from the China Health and Retirement Longitudinal Study (CHARLS). Results reveal a significant non-linear relationship between the comprehensive heat risk index and the prevalence of cardiovascular and cerebrovascular diseases (R2 = 0.739), indicating strong explanatory power for health risks. Spatially, heat risk exhibits a center–periphery gradient, with high-risk areas concentrated in older central districts. Heat adaptation is identified as a key regulatory factor that can either mitigate or amplify risk accumulation. Based on the spatial heterogeneity of different neighborhood types, targeted mitigation strategies are proposed, providing scientific support for urban renewal and heat resilience governance.

  • Open Access

    Feedback Effects of Air-Conditioning Anthropogenic Heat on Cooling Energy Consumption in Residential Buildings: A CFD–EnergyPlus Co-Simulation Study

    by Chengliang Fan, Jie Chen, Peng Yu

    With global warming and accelerated urbanization, building air-conditioning (AC) releases more heat into the environment, exacerbating the urban heat island (UHI) effects and increasing building cooling energy consumption. Existing research has limited quantification of the impact of air-conditioning anthropogenic heat (ACAH) on the cooling energy consumption of different types. This study aims to explore the distribution characteristics of ACAH and its impact on residential building energy consumption. Firstly, typical residential buildings in the Pearl River Delta region were selected as a case study. Field experiments were conducted to measure temperature and humidity at 0.5 m, 1 m, 2 m, and 3 m from the outdoor unit, alongside ambient temperature and wind speed. Three grid densities were applied to verify the CFD model, with a prediction error of less than 0.3 °C at 0.5 m under a medium grid. The simulated temperature at 1 m from the outdoor unit under calm wind conditions was compared with field measurements to reveal the horizontal and vertical distribution characteristics of ACAH. Secondly, the effects of different building shapes, ambient temperatures, and wind speeds on the spatial distribution of ACAH were investigated. Finally, EnergyPlus (V23.1.0) was employed as the building energy simulation software, with its microclimate coupling interface implemented via Python scripts to quantify cooling energy consumption variations across different building floors under ACAH influence. Results indicated that ACAH exhibits significant horizontal non-uniformity, exerting the greatest impact within a 0.5 m radius (affected air temperature 4.3 °C higher than ambient). Vertically, localized heat accumulation occurs in the building’s central area, with air temperature 3.5 °C higher than at the bottom. Furthermore, compared to fixed meteorological conditions, the cooling energy consumption difference across floors considering ACAH reaches approximately 7.8%. This study provides accurate meteorological boundary conditions for building energy assessment and supports microclimate management in residential areas.


  • An improved model of indoor overheating degree that integrates weather and building parameters for thermal resilience evaluation

    by Xiang Zhu, Xiaoqing Zhou, Yongbo Cui, Chengliang Fan

    The increasing frequency and severity of heat events driven by global warming highlight the need to assess the thermal resilience of buildings under normal operating conditions. The indoor overheating degree (IOD) is a widely adopted metric for quantifying thermal performance. However, its applicability to diverse building thermal resilience assessments is limited due to a lack of relevant data. To address this, this study introduced an improved IOD model that integrates weather conditions and building parameters for the evaluation of indoor thermal performance. The model’s effectiveness was demonstrated through a case study of a residential building in Guangzhou, China. In this study, the most influential factor on the IOD was the outdoor temperature, followed by solar radiation transmittance, the heat transfer coefficient of wall and window, lastly the indoor heat dissipation values. The results showed that by reducing the heat transfer coefficients of walls and windows by 80% and the solar radiation transmittance by 66.7% have yielded IOD reductions of 12.5%, 13.5% and 30.8%, respectively. This study presents an improved IOD model for assessing building thermal resilience, leveraging readily available climatic and building parameter data. It offers a scalable framework for supporting the design of adaptive strategies.


  • Open Access

    Archetype Identification and Energy Consumption Prediction for Old Residential Buildings Based on Multi-Source Datasets

    by Chengliang Fan, Rude Liu, Yundan Liao

    Assessing energy consumption in existing old residential buildings is key for urban energy conservation and decarbonization. Previous studies on old residential building energy assessment face challenges due to data limitations and inadequate prediction methods. This study develops a novel approach integrating building energy simulation and machine learning to predict large-scale old residential building energy use using multi-source datasets. Using Guangzhou as a case study, open-source building data was collected to identify 31,209 old residential buildings based on age thresholds and areas of interest (AOIs). Key building form parameters (i.e., long side, short side, number of floors) were then classified to identify residential archetypes. Building energy consumption data for each prototype was generated using EnergyPlus (V23.2.0) simulations. Furthermore, XGBoost and Random Forest machine learning algorithms were used to predict city-scale old residential building energy consumption. Results indicated that five representative prototypes exhibited cooling energy use ranging from 17.32 to 21.05 kWh/m2, while annual electricity consumption ranged from 60.10 to 66.53 kWh/m2. The XGBoost model demonstrated strong predictive performance (R2 = 0.667). SHAP (Shapley Additive Explanations) analysis identified the Building Shape Coefficient (BSC) as the most significant positive predictor of energy consumption (SHAP value = 0.79). This framework enables city-level energy assessment for old residential buildings, providing critical support for retrofitting strategies in sustainable urban renewal planning.


  • Open Access

    Integrating bottom-up energy model with urban parameterization for fine-scale anthropogenic heat estimation

    by Yichuan Chen, Chengliang Fan, Yuanyue Nie, Huixian Wu, Yingfen Zhu, Yundan Liao, Haoran Li, Liuyang Wu, Minjing Lao


  • Optimizing glass roof design for green buildings by evaluating co-benefit of indoor daylighting and cooling load

    by Yundan Liao, Simin Yang, Jie Dong, Yuan Gu, Chengliang Fan

    Glass roofs have become a pivotal element in the design of green buildings, playing a crucial role in balancing daylighting and heat gain performance. This research aims to investigate the cooling load and daylight illuminance under various glass roof design parameters. Firstly, three primary design parameters were identified and parameterized: tilt angle, material and skylight-to-roof area ratio (AR). Secondly, a simulation model was developed to evaluate the photothermal performance of glass roofs under four different materials. Thirdly, a co-benefit evaluation method was introduced to quantify the impacts of the design parameters of glass roofs on daylighting and heat gain performance. The results showed that co-benefit indicators rose from 0.56% to 30.95% with the increase in transparency and heat transfer efficiency. Amongst Materials 1 to 4, co-benefit variation grew from 0.002% to 7.15%, showing that the optimal glass roofing combination varied based on design parameters. Glass Roof Material 2, with a tilt angle of 10° and a skylight-to-roof AR of 10%, was identified as the optimal option. Finally, the co-benefit evaluation method for photothermal performance was applied to a real building. Co-benefit index gradually increased from 28.16% baseline to 71.04% for Material 2. The proposed method can generate optimal values for each type of building glass roofs, providing designers with valuable design recommendations tailored to their specific needs.


  • Promoting the design of future indoor environmental to improve air pollution: Based on the analysis of hazardous substances in indoor PM2.5 pollution in cold regions

    by Yongbo Cui, Chengliang Fan, Xiaoqing Zhou

    People spend about 90% of their day indoors and are at increased risk of exposure to metal elements (MEs), water-soluble ions (WSIs) and polycyclic aromatic hydrocarbons (PAHs) contained in indoor PM2.5. Therefore, firstly this study investigated indoor PM2.5 pollution to explore the distribution characteristics of MEs, WSIs and PAHs. Secondly, the carcinogenic risk of MEs and PAH to the population was analyzed using health risk assessment models. Finally, the sources of MEs and PAHs were identified using statistical analyses. The results of the study show that PM2.5 concentrations fluctuate between spring and winter, with the most significant fluctuations reaching around 100 µg/m3 in March and January. Concentrations of most MEs, WSIs and PAHs during the heating season are twice as high as during the non-heating season. The main sources of MEs and PAHs are industrial, coal-fired emission sources, vehicle exhaust and metallurgical chemical emission sources. The non-carcinogenic and carcinogenic risks of metallic elements to the population are mainly due to Co, which contribute up to 80% in both adults and children. The carcinogenicity risk indices of the six monomeric PAHs, BaP, DbA, Bbf, Bkf, Inp and BaA, were greater than 10–6, indicating a potential carcinogenic risk.