Sreypich Say
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sreypich Say has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Akio Kishida
Laboratory for Biomaterials and Bioengineering, Institute of Integrated Research, Institute of Science Tokyo, Tokyo 101-0062, Japan
3 shared publications Mika Suzuki
Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Institute of Biomaterials and Bioengineering, Chiyoda-ku, Tokyo, 101-0062, JAPAN
2 shared publications- Sopheap Sam
Institute of Technology of Cambodia, Russian Federation Blvd
2 shared publications - Tsuyoshi Kimura
Department of Biomedical Engineering, Faculty of Life Science, Toyo University, 48-1 Oka, Asaka-shi 351-8510, Saitama, Japan
2 shared publications Yoshihide Hashimoto
Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Institute of Biomaterials and Bioengineering, Chiyoda-ku, Tokyo, 101-0062, JAPAN
2 shared publicationsHiroshi Nakatsugawa
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Elsevier in Next Energy
- Vol. 11
Nanostructuring thermoelectric materials using phononic crystals and reduction in lattice thermal conductivity
- 10 March 2026
- Published by Elsevier in Next Energy
- Vol. 11
Open AccessNanostructuring thermoelectric materials using phononic crystals and reduction in lattice thermal conductivity
- Open Access
- 28 November 2025
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 26 (1)
Strategies to improve the thermoelectric performance of iron silicide-based materials
Iron silicide (β-FeSi2) has attracted considerable interest as a sustainable thermoelectric material due to its abundance, non-toxicity, and environmental compatibility. Their conduction flexibility allows a wide range of dopants to tune transport behavior, creating opportunities for improved performance. However, dopant solubility limits and the formation of secondary phases remain key challenges. In this article, we highlight recent advances in strategies to enhance the thermoelectric performance of β-FeSi2-based materials and discuss the interplay between phase evolution, electrical, and thermal transport. We also outline prospects that may unlock further improvements, offering pathways toward higher thermoelectric efficiency in this material system.
- 28 November 2025
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 26 (1)
Open AccessStrategies to improve the thermoelectric performance of iron silicide-based materials
Iron silicide (β-FeSi2) has attracted considerable interest as a sustainable thermoelectric material due to its abundance, non-toxicity, and environmental compatibility. Their conduction flexibility allows a wide range of dopants to tune transport behavior, creating opportunities for improved performance. However, dopant solubility limits and the formation of secondary phases remain key challenges. In this article, we highlight recent advances in strategies to enhance the thermoelectric performance of β-FeSi2-based materials and discuss the interplay between phase evolution, electrical, and thermal transport. We also outline prospects that may unlock further improvements, offering pathways toward higher thermoelectric efficiency in this material system.
- Open Access
- 1 November 2024
- Published by MDPI AG in Materials Proceedings
- Vol. 19 (1) , 3
Fibroblast and THP-1 Cell Response to Multi-Arm PEGNHS-Modified Decellularized Porcine Pericardium
The adhesion between an implant and a wound could result in over-bleeding when attempting to separate the two. To address this issue, a cell-repelling implant is preferred. In this study, a cell-repelling membrane was prepared by modifying decellularized porcine pericardium with multi-arm polyethylene glycol. With this modification technology, we switched the surface properties of the decellularized porcine pericardium from cell-adhering to cell-repelling. The result showed that this pericardium was successfully modified without any effect on the original properties of the pericardium and also maintained a low inflammatory response. The level of cell adhesion on the surface of the membrane was significantly reduced.
- 1 November 2024
- Published by MDPI AG in Materials Proceedings
- Vol. 19 (1) , 3
Open AccessFibroblast and THP-1 Cell Response to Multi-Arm PEGNHS-Modified Decellularized Porcine Pericardium
The adhesion between an implant and a wound could result in over-bleeding when attempting to separate the two. To address this issue, a cell-repelling implant is preferred. In this study, a cell-repelling membrane was prepared by modifying decellularized porcine pericardium with multi-arm polyethylene glycol. With this modification technology, we switched the surface properties of the decellularized porcine pericardium from cell-adhering to cell-repelling. The result showed that this pericardium was successfully modified without any effect on the original properties of the pericardium and also maintained a low inflammatory response. The level of cell adhesion on the surface of the membrane was significantly reduced.
- Open Access
- 29 February 2024
- Published by IOP Publishing in Biomedical Materials
- Vol. 19 (3) , 035012
Investigation of anti-adhesion ability of 8-arm PEGNHS-modified porcine pericardium
In post-adhesion surgery, there is a clinical need for anti-adhesion membranes specifically designed for the liver, given the limited efficacy of current commercial products. To address this demand, we present a membrane suitable for liver surgery applications, fabricated through the modification of decellularized porcine pericardium with 20 KDa hexaglycerol octa (succinimidyloxyglutaryl) polyoxyethylene (8-arm PEGNHS). We also developed an optimized modification procedure to produce a high-performance anti-adhesion barrier. The modified membrane significantly inhibited fibroblast cell adherence while maintaining minimal levels of inflammation. By optimizing the modification ratio, we successfully controlled post-adhesion formation. Notably, the 8-arm PEG-modified pericardium with a molar ratio of 5 exhibited the ability to effectively prevent post-adhesion formation on the liver compared to both the control and Seprafilm®, with a low adhesion score of 0.5 out of 3.0. Histological analysis further confirmed its potential for easy separation. Furthermore, the membrane demonstrated regenerative capabilities, as evidenced by the proliferation of mesothelial cells on its surface, endowing anti-adhesion properties between the abdominal wall and liver. These findings highlight the membrane’s potential as a reliable barrier for repeated liver resection procedures that require the removal of the membrane multiple times.
- 29 February 2024
- Published by IOP Publishing in Biomedical Materials
- Vol. 19 (3) , 035012
Open AccessInvestigation of anti-adhesion ability of 8-arm PEGNHS-modified porcine pericardium
In post-adhesion surgery, there is a clinical need for anti-adhesion membranes specifically designed for the liver, given the limited efficacy of current commercial products. To address this demand, we present a membrane suitable for liver surgery applications, fabricated through the modification of decellularized porcine pericardium with 20 KDa hexaglycerol octa (succinimidyloxyglutaryl) polyoxyethylene (8-arm PEGNHS). We also developed an optimized modification procedure to produce a high-performance anti-adhesion barrier. The modified membrane significantly inhibited fibroblast cell adherence while maintaining minimal levels of inflammation. By optimizing the modification ratio, we successfully controlled post-adhesion formation. Notably, the 8-arm PEG-modified pericardium with a molar ratio of 5 exhibited the ability to effectively prevent post-adhesion formation on the liver compared to both the control and Seprafilm®, with a low adhesion score of 0.5 out of 3.0. Histological analysis further confirmed its potential for easy separation. Furthermore, the membrane demonstrated regenerative capabilities, as evidenced by the proliferation of mesothelial cells on its surface, endowing anti-adhesion properties between the abdominal wall and liver. These findings highlight the membrane’s potential as a reliable barrier for repeated liver resection procedures that require the removal of the membrane multiple times.
- 21 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (5) , 1244-1256
Effect of multi arm-PEG-NHS (polyethylene glycol n-hydroxysuccinimide) branching on cell adhesion to modified decellularized bovine and porcine pericardium
Implanting physical barrier materials to separate wounds from their surroundings is a promising strategy for preventing postoperative adhesions. Herein, we develop a material that switches from an anti-adhesive surface to an adhesive surface, preventing adhesion in the early stage of transplantation and then promoting recellularization. In this study, 2-arm, 4-arm, and 8-arm poly(ethylene glycol) succinimidyl glutarate (2-, 4-, 8-arm PEG-NHS) were used to modify the surface of decellularized porcine and bovine pericardium. The number of free amines on the surface of each material significantly decreased following modification regardless of the reaction molar ratio of NH2 and NHS, the number of PEG molecule branches, and the animal species of the decellularized tissue. The structure and mechanical properties of the pericardium were maintained after modification with PEG molecules. The time taken for the PEG molecules to detach through hydrolysis of the ester bonds differed between the samples, which resulted in different cell repulsion periods. By adjusting the reaction molar ratio, the number of PEG molecule branches, and the animal species of the decellularized pericardium, the duration of cell repulsion can be controlled and is expected to provide an anti-adhesion material for a variety of surgical procedures.
- 21 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 12 (5) , 1244-1256
Effect of multi arm-PEG-NHS (polyethylene glycol n-hydroxysuccinimide) branching on cell adhesion to modified decellularized bovine and porcine pericardium
Implanting physical barrier materials to separate wounds from their surroundings is a promising strategy for preventing postoperative adhesions. Herein, we develop a material that switches from an anti-adhesive surface to an adhesive surface, preventing adhesion in the early stage of transplantation and then promoting recellularization. In this study, 2-arm, 4-arm, and 8-arm poly(ethylene glycol) succinimidyl glutarate (2-, 4-, 8-arm PEG-NHS) were used to modify the surface of decellularized porcine and bovine pericardium. The number of free amines on the surface of each material significantly decreased following modification regardless of the reaction molar ratio of NH2 and NHS, the number of PEG molecule branches, and the animal species of the decellularized tissue. The structure and mechanical properties of the pericardium were maintained after modification with PEG molecules. The time taken for the PEG molecules to detach through hydrolysis of the ester bonds differed between the samples, which resulted in different cell repulsion periods. By adjusting the reaction molar ratio, the number of PEG molecule branches, and the animal species of the decellularized pericardium, the duration of cell repulsion can be controlled and is expected to provide an anti-adhesion material for a variety of surgical procedures.
- Open Access
- 20 February 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 268, 01009
Effect of sonication power on perfusion decellularization of cadaveric porcine kidney
Kidney problems rank 7th among the top 10 causes of mortality among Filipinos. One of the potential future treatment options is the use of bioengineered kidney. The preparation of scaffolds is the first step in kidney bioengineering and perfusion decellularization using chemicals is considered the most preferred preparation method to date. However, the use of chemicals alone requires long treatment time hence, in this study perfusion decellularization is to be enhanced by sonication treatment at varying sonication power. Decellularization was carried out by perfusing the kidney with 1% SDS and was subjected to sonication treatment with a 2h sonication and 2h rest cycle. The cycle is repeated until the kidney is clear and transparent. Washing using 1% Triton X-100 and 1x PBS then follows to remove residual SDS. The extent of cell removal was determined by H&E staining. The results showed that decellularization with sonication using 150W, 200W and 250W required a treatment time of 24h, 16h and 12h respectively compared to the 28h treatment time of decellularization without sonication. The result clearly shows that with higher sonication power, the shorter is the decellularization time needed to prepare a good kidney scaffold.
- 20 February 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 268, 01009
Open AccessEffect of sonication power on perfusion decellularization of cadaveric porcine kidney
Kidney problems rank 7th among the top 10 causes of mortality among Filipinos. One of the potential future treatment options is the use of bioengineered kidney. The preparation of scaffolds is the first step in kidney bioengineering and perfusion decellularization using chemicals is considered the most preferred preparation method to date. However, the use of chemicals alone requires long treatment time hence, in this study perfusion decellularization is to be enhanced by sonication treatment at varying sonication power. Decellularization was carried out by perfusing the kidney with 1% SDS and was subjected to sonication treatment with a 2h sonication and 2h rest cycle. The cycle is repeated until the kidney is clear and transparent. Washing using 1% Triton X-100 and 1x PBS then follows to remove residual SDS. The extent of cell removal was determined by H&E staining. The results showed that decellularization with sonication using 150W, 200W and 250W required a treatment time of 24h, 16h and 12h respectively compared to the 28h treatment time of decellularization without sonication. The result clearly shows that with higher sonication power, the shorter is the decellularization time needed to prepare a good kidney scaffold.