Xin Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xin Jin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Xiao-Jing Liu
ShanghaiTech University
2 shared publications - Bocheng Ding
School Physical Science and Technology, ShanghaiTech University, Shanghai 201210, China
1 shared publication Jianfei Tao
School of Physical Science and Technology, ShanghaiTech University 1 , Shanghai 201210
1 shared publicationJianfeng Liao
Center for Transformative Science, ShanghaiTech University 2 , Shanghai 201210
1 shared publication- Jianfeng Liao
School Physical Science and Technology, ShanghaiTech University, Shanghai 201210, China
1 shared publication - Jianye Huang
School Physical Science and Technology, ShanghaiTech University, Shanghai 201210, China
1 shared publication
Latest Publications
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
A co-axial velocity map imaging spectrometer for polarization-driven ionization
We report on a co-axial velocity map imaging (VMI) spectrometer in which the laser beam propagates along the spectrometer axis and the laser polarization plane is parallel to the detector. As a result, polarization-driven processes are recorded with much more detail compared to normal VMI. Simulation using SIMION predicts an exceptional relative energy resolution of 0.3% at kinetic energy ∼60 eV. Experimental validation via above-threshold ionization of xenon demonstrates two key properties: (1) a relative energy resolution of 5.5% at 11.5 eV of kinetic energy and (2) direct observation of attosecond angular streaking effects in photoelectron momentum distributions. These capabilities establish the spectrometer as a powerful tool for attosecond experiments.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
A co-axial velocity map imaging spectrometer for polarization-driven ionization
We report on a co-axial velocity map imaging (VMI) spectrometer in which the laser beam propagates along the spectrometer axis and the laser polarization plane is parallel to the detector. As a result, polarization-driven processes are recorded with much more detail compared to normal VMI. Simulation using SIMION predicts an exceptional relative energy resolution of 0.3% at kinetic energy ∼60 eV. Experimental validation via above-threshold ionization of xenon demonstrates two key properties: (1) a relative energy resolution of 5.5% at 11.5 eV of kinetic energy and (2) direct observation of attosecond angular streaking effects in photoelectron momentum distributions. These capabilities establish the spectrometer as a powerful tool for attosecond experiments.
- Open Access
- 6 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 2190
Spatial and Momentum Mapping Modes for Velocity Map Imaging Spectrometer
The velocity map imaging (VMI) technique is used to acquire the momentum distribution of charged particles. Here, we introduce two additional operation modes for our recently built velocity map imaging (VMI) spectrometer: the spatial mapping mode that magnifies the image of zero energy ions with different scales and the high-resolution momentum mapping mode that acquires the electron momentum distribution at the kinetic energy of about 100 eV. In simulations, the ion image is magnified with a factor of up to 7.6, and a relative resolution of 0.15% at 150 eV electron kinetic energy is predicted. Switching between these two modes helps reduce the alignment error to below 0.2 mm. In the test using the above-threshold ionization (ATI) of argon (Ar), the Ar+ ion image is magnified by a factor of up to 6.7, and a relative resolution of 1.3% at 44.6 eV electron kinetic energy is achieved.
- 6 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 2190
Open AccessSpatial and Momentum Mapping Modes for Velocity Map Imaging Spectrometer
The velocity map imaging (VMI) technique is used to acquire the momentum distribution of charged particles. Here, we introduce two additional operation modes for our recently built velocity map imaging (VMI) spectrometer: the spatial mapping mode that magnifies the image of zero energy ions with different scales and the high-resolution momentum mapping mode that acquires the electron momentum distribution at the kinetic energy of about 100 eV. In simulations, the ion image is magnified with a factor of up to 7.6, and a relative resolution of 0.15% at 150 eV electron kinetic energy is predicted. Switching between these two modes helps reduce the alignment error to below 0.2 mm. In the test using the above-threshold ionization (ATI) of argon (Ar), the Ar+ ion image is magnified by a factor of up to 6.7, and a relative resolution of 1.3% at 44.6 eV electron kinetic energy is achieved.