Sotiris Spanos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sotiris Spanos has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Konstantinos Karantzalos
National Technical University of Athens, Athens, Greece
2 shared publications - Valsamis Ntouskos
Department of Engineering and Sciences, Universitas Mercatorum, Rome, Italy
2 shared publications - Angelos Mallios
Institute of Informatics and Applications, Universitat de Girona, Spain
1 shared publication C. Antoniou
Natl Tech Univ Athens, Remote Sensing Lab, Iroon Polytech 9, Zografos 15772, Greece
1 shared publication- Dionysis Christopoulos
Remote Sensing Laboratory, National Technical University of Athens, Athens, Greece
1 shared publication V. Tsironis
Natl Tech Univ Athens, Remote Sensing Lab, Iroon Polytech 9, Zografos 15772, Greece
1 shared publication
Latest Publications
- Open Access
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 101721-101734
TRACE: Transformer-Based Risk Assessment for Clinical Evaluation
We present TRACE (Transformer-based Risk Assessment for Clinical Evaluation), a novel method for clinical risk assessment based on clinical data, leveraging the self-attention mechanism for enhanced feature interaction and result interpretation. Our approach is able to handle different data modalities, including continuous, categorical and multiple-choice (checkbox) attributes. The proposed architecture features a shared representation of the clinical data obtained by integrating specialized embeddings of each data modality, enabling the detection of high-risk individuals using Transformer encoder layers. To assess the effectiveness of the proposed method, a strong baseline based on non-negative multi-layer perceptrons (MLPs) is introduced. The proposed method outperforms various baselines widely used in the domain of clinical risk assessment, while effectively handling missing values. In terms of explainability, our Transformer-based method offers easily interpretable results via attention weights, further enhancing the clinicians’ decision-making process.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 101721-101734
Open AccessTRACE: Transformer-Based Risk Assessment for Clinical Evaluation
We present TRACE (Transformer-based Risk Assessment for Clinical Evaluation), a novel method for clinical risk assessment based on clinical data, leveraging the self-attention mechanism for enhanced feature interaction and result interpretation. Our approach is able to handle different data modalities, including continuous, categorical and multiple-choice (checkbox) attributes. The proposed architecture features a shared representation of the clinical data obtained by integrating specialized embeddings of each data modality, enabling the detection of high-risk individuals using Transformer encoder layers. To assess the effectiveness of the proposed method, a strong baseline based on non-negative multi-layer perceptrons (MLPs) is introduced. The proposed method outperforms various baselines widely used in the domain of clinical risk assessment, while effectively handling missing values. In terms of explainability, our Transformer-based method offers easily interpretable results via attention weights, further enhancing the clinicians’ decision-making process.
- Open Access
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03012
Preliminary results from the Submarine Gamma Imager
In this work, we present preliminary results of a novel Submarine Gamma Imager (SUGI) being developed based on pixelated CdZnTe detector modules. The instrument, mounted on a remotely operated vehicle (ROV), has been tested in a series of field deployments performed at the hydrothermal fields on the island of Milos, Greece. The analysis of the collected data demonstrate the capabilities of the instrument, while comparison with a reference gamma detector confirms the validity of the results.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03012
Open AccessPreliminary results from the Submarine Gamma Imager
In this work, we present preliminary results of a novel Submarine Gamma Imager (SUGI) being developed based on pixelated CdZnTe detector modules. The instrument, mounted on a remotely operated vehicle (ROV), has been tested in a series of field deployments performed at the hydrothermal fields on the island of Milos, Greece. The analysis of the collected data demonstrate the capabilities of the instrument, while comparison with a reference gamma detector confirms the validity of the results.