Li Zhang
Research Subjects
Li Zhang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
China Aero Geophysical Survey and Remote Sensing Center for Natural Resources, Beijing, China
2 shared publications - Daqing Ge
China Aero Geophysical Survey and Remote Sensing Center for Natural Resources, Beijing 100083, China
2 shared publications Xiangxing Wan
China Aero Geophysical Survey and Remote Sensing Center for Natural Resources, Beijing, China
2 shared publications- Chunle Wang
Department of Space Microwave Remote Sensing System, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
1 shared publication - Gaoyun Shen
Southwest Petroleum University
1 shared publication - Jie Dong
Wuhan University
1 shared publication
Latest Publications
- Open Access
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19 (19391404) , 15488-15507
Applicability Analysis of InSAR Tropospheric Delay Correction for Landslide Monitoring Considering Periodicity Characteristics—Case Study on Southwest Mountainous Region
Tropospheric delay is a major limitation in Interferometric Synthetic Aperture Radar (InSAR) for measuring landslide deformation. It exhibits complex spatial-temporal variability, stochastic behavior, and is particularly difficult to model in the mountainous areas of southwest China, where terrain is highly heterogeneous. Accurate estimation of tropospheric delay is therefore critical for improving the precision of InSAR-based landslide monitoring. In this study, we propose a tropospheric delay correction method that explicitly accounts for its periodic characteristics and evaluate its applicability in landslide monitoring across the mountainous regions of southwest China. By analyzing the temporal characteristics of tropospheric delay, we examine its periodic properties and construct a model that combines periodic and stochastic properties to estimate the delay. The method is applied to Sentinel-1 time-series InSAR data in southwestern mountainous study areas, with performance assessed at the levels of interferograms, linear deformation rates, and time-series. Results show that, in both study areas, more than 98% of single-master interferograms exhibit a reduced standard deviation (std), with average reductions exceeding 40% and maximum improvements surpassing 80% in interferometric phase std. These findings demonstrates that the proposed temporal tropospheric delay correction method effectively accounts for both time-related and stochastic components of tropospheric delay, substantially mitigating its impact spatially and temporally. Consequently, this approach significantly enhances the accuracy and reliability of InSAR-based landslide monitoring.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19 (19391404) , 15488-15507
Open AccessApplicability Analysis of InSAR Tropospheric Delay Correction for Landslide Monitoring Considering Periodicity Characteristics—Case Study on Southwest Mountainous Region
Tropospheric delay is a major limitation in Interferometric Synthetic Aperture Radar (InSAR) for measuring landslide deformation. It exhibits complex spatial-temporal variability, stochastic behavior, and is particularly difficult to model in the mountainous areas of southwest China, where terrain is highly heterogeneous. Accurate estimation of tropospheric delay is therefore critical for improving the precision of InSAR-based landslide monitoring. In this study, we propose a tropospheric delay correction method that explicitly accounts for its periodic characteristics and evaluate its applicability in landslide monitoring across the mountainous regions of southwest China. By analyzing the temporal characteristics of tropospheric delay, we examine its periodic properties and construct a model that combines periodic and stochastic properties to estimate the delay. The method is applied to Sentinel-1 time-series InSAR data in southwestern mountainous study areas, with performance assessed at the levels of interferograms, linear deformation rates, and time-series. Results show that, in both study areas, more than 98% of single-master interferograms exhibit a reduced standard deviation (std), with average reductions exceeding 40% and maximum improvements surpassing 80% in interferometric phase std. These findings demonstrates that the proposed temporal tropospheric delay correction method effectively accounts for both time-related and stochastic components of tropospheric delay, substantially mitigating its impact spatially and temporally. Consequently, this approach significantly enhances the accuracy and reliability of InSAR-based landslide monitoring.
- Open Access
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6455-6467
An Improved Urban Area Extraction Method for PolSAR Data Using Eigenvalues and Optimal Roll-Invariant Features
Urban area extraction using polarimetric synthetic aperture radar (PolSAR) data is an important application for urban planning and disaster assessment. Due to the variability in urban structures, the problem of mistaking built-up areas for vegetation remains challenging. Then, a new urban extraction method is proposed using eigenvalues and optimal roll-invariant features. First, similar to the entropy/anisotropy plane, a 2-D RVI/PA plane is adopted to construct the extractor of surface scattering areas. Then, the optimal ratio of the correlation coefficient is proposed as an extractor to depict the scattering characteristics of buildings with various orientation angles, while restraining the scattering characteristics of other land covers. In addition, reliable hidden features are selected to refine the extraction results. Finally, the spatial information extraction and classification methods are introduced to automatically determine the thresholds of parameters above, based on which the urban area extraction map can be obtained. C-band Gaofen-3 SAR data collected in Runan, Henan Province, China and San Francisco, USA, and L-band E-SAR data collected in Oberpfaffenhofen, Germany are used to validate the performance of the proposed method. Experimental results demonstrate that the method can distinguish between urban and natural areas with high accuracy and has good visual effects in extracting building areas.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6455-6467
Open AccessAn Improved Urban Area Extraction Method for PolSAR Data Using Eigenvalues and Optimal Roll-Invariant Features
Urban area extraction using polarimetric synthetic aperture radar (PolSAR) data is an important application for urban planning and disaster assessment. Due to the variability in urban structures, the problem of mistaking built-up areas for vegetation remains challenging. Then, a new urban extraction method is proposed using eigenvalues and optimal roll-invariant features. First, similar to the entropy/anisotropy plane, a 2-D RVI/PA plane is adopted to construct the extractor of surface scattering areas. Then, the optimal ratio of the correlation coefficient is proposed as an extractor to depict the scattering characteristics of buildings with various orientation angles, while restraining the scattering characteristics of other land covers. In addition, reliable hidden features are selected to refine the extraction results. Finally, the spatial information extraction and classification methods are introduced to automatically determine the thresholds of parameters above, based on which the urban area extraction map can be obtained. C-band Gaofen-3 SAR data collected in Runan, Henan Province, China and San Francisco, USA, and L-band E-SAR data collected in Oberpfaffenhofen, Germany are used to validate the performance of the proposed method. Experimental results demonstrate that the method can distinguish between urban and natural areas with high accuracy and has good visual effects in extracting building areas.