UGUnay Dorken Gallastegi

Unay Dorken Gallastegi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Unay Dorken Gallastegi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • SeqEyes : An Open‐Source Toolbox for Synchronized Waveform/Trajectory Visualization in Pulseq

    by Xingwang Yong, Zheng Liu, Yiyun Dong, Haotian Hong, Yuting Chen, Paul Dubovan, Qiang Liu, Jiye Kim, Unay Dorken Gallastegi, Yohan Jun, et al.

    Pulseq enables vendor‐neutral description of MRI pulse sequences in human‐readable .seq files and is widely used for sequence development and sharing. During design and debugging, rapid evaluation of sequence timing across RF pulses, gradient waveforms, and ADC events is essential. This is particularly challenging for non‐Cartesian acquisitions, where waveform timing does not readily reveal the underlying k ‐space trajectory. Existing tools, however, provide limited interactive capabilities for this task. Here, we introduce SeqEyes, an interactive viewer for Pulseq .seq files tailored for efficient sequence analysis. The software parses .seq files to provide synchronized visualization of RF, gradient, and ADC waveforms alongside their corresponding k ‐space trajectories. This establishes a direct link between sequence structure and sampling behavior within a single interface. The tool supports interactive navigation across time, TRs, and sequence blocks, as well as event‐level timing verification, visualization of Pulseq extensions, and diagnostic overlays. SeqEyes features a graphical user interface, complemented by command‐line, Python, and MATLAB interfaces for integration into existing research workflows. By unifying waveform and trajectory visualizations, this open‐source toolbox optimizes the routine validation of Pulseq sequences, ultimately reducing the barrier to developing and sharing complex MRI acquisitions.

  • Ozone Cues Mitigate Reflected Downwelling Radiance in LWIR Absorption-Based Ranging

    by Unay Dorken Gallastegi, Wentao Shangguan, Vaibhav Choudhary, Akshay Agarwal, Hoover Rueda-Chacón, Martin J. Stevens, Vivek K Goyal

    Passive long-wave infrared (LWIR) absorption-based ranging relies on atmospheric absorption to estimate distances to objects from their emitted thermal radiation. First demonstrated decades ago for objects much hotter than the air and recently extended to scenes with low temperature variations, this ranging has depended on reflected radiance being negligible. Downwelling radiance is especially problematic, sometimes causing large inaccuracies. In two new ranging methods, we use characteristic features from ozone absorption to estimate the contribution of reflected downwelling radiance. The quadspectral method gives a simple closed-form range estimate from four narrowband measurements, two at a water vapor absorption line and two at an ozone absorption line. The hyperspectral method uses a broader spectral range to improve accuracy while also providing estimates of temperature, emissivity profiles, and contributions of downwelling from a collection of zenith angles. Experimental results demonstrate improved ranging accuracy, in one case reducing error from over 100 m when reflected light is not modeled to 6.8 m with the quadspectral method and 1.2 m with the hyperspectral method.


  • Absorption-Based, Passive Range Imaging From Hyperspectral Thermal Measurements

    by Unay Dorken Gallastegi, Hoover Rueda-Chacón, Martin J. Stevens, Vivek K Goyal

    Passive hyperspectral longwave infrared measurements are remarkably informative about the surroundings. Remote object material and temperature determine the spectrum of thermal radiance, and range, air temperature, and gas concentrations determine how this spectrum is modified by propagation to the sensor. We introduce a passive range imaging method based on computationally separating these phenomena. Previous methods assume hot and highly emitting objects; ranging is more challenging when objects' temperatures do not deviate greatly from air temperature. Our method jointly estimates range and intrinsic object properties, with explicit consideration of air emission, though reflected light is assumed negligible. Inversion being underdetermined is mitigated by using a parametric model of atmospheric absorption and regularizing for smooth emissivity estimates. To assess where our estimate is likely accurate, we introduce a technique to detect which scene pixels are significantly influenced by reflected downwelling. Monte Carlo simulations demonstrate the importance of regularization, temperature differentials, and availability of many spectral bands. We apply our method to longwave infrared (8–13 $\mu$ m) hyperspectral image data acquired from natural scenes with no active illumination. Range features from 15 m to 150 m are recovered, with good qualitative match to lidar data for pixels classified as having negligible reflected downwelling.


  • Absorption-based hyperspectral thermal ranging: performance analyses, optimization, and simulations

    by Unay Dorken Gallastegi, Hoover Rueda-Chacón, Martin J. Stevens, Vivek K Goyal

    The wavelength dependence of atmospheric absorption creates range cues in hyperspectral measurements that can be exploited for passive ranging using only thermal emissions. In this work, we present fundamental limits on absorption-based ranging under a model of known air temperature and wavelength-dependent attenuation coefficient, with object temperature and emissivity unknown; reflected solar and environmental radiance is omitted from our analysis. Fisher information computations illustrate how performance limits depend on atmospheric conditions such as air temperature and humidity; temperature contrast in the scene; spectral resolution of measurement; and distance. These results should prove valuable in sensor system design.