Unay Dorken Gallastegi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Unay Dorken Gallastegi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hoover Rueda-Chacón
Boston University, Boston, MA, USA
3 shared publications - Martin J. Stevens
National Institute of Standards and Technology, Boulder, CO, USA
3 shared publications - Vivek K. Goyal
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
3 shared publications - Akshay Agarwal
Boston University, Boston, MA, USA
1 shared publication - Berkin Bilgic
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States
1 shared publication Haotian Hong
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital Charlestown Massachusetts USA
1 shared publication
Latest Publications
- 28 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 331-339
SeqEyes : An Open‐Source Toolbox for Synchronized Waveform/Trajectory Visualization in Pulseq
Pulseq enables vendor‐neutral description of MRI pulse sequences in human‐readable .seq files and is widely used for sequence development and sharing. During design and debugging, rapid evaluation of sequence timing across RF pulses, gradient waveforms, and ADC events is essential. This is particularly challenging for non‐Cartesian acquisitions, where waveform timing does not readily reveal the underlying k ‐space trajectory. Existing tools, however, provide limited interactive capabilities for this task. Here, we introduce SeqEyes, an interactive viewer for Pulseq .seq files tailored for efficient sequence analysis. The software parses .seq files to provide synchronized visualization of RF, gradient, and ADC waveforms alongside their corresponding k ‐space trajectories. This establishes a direct link between sequence structure and sampling behavior within a single interface. The tool supports interactive navigation across time, TRs, and sequence blocks, as well as event‐level timing verification, visualization of Pulseq extensions, and diagnostic overlays. SeqEyes features a graphical user interface, complemented by command‐line, Python, and MATLAB interfaces for integration into existing research workflows. By unifying waveform and trajectory visualizations, this open‐source toolbox optimizes the routine validation of Pulseq sequences, ultimately reducing the barrier to developing and sharing complex MRI acquisitions.
- 28 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 97 (1) , 331-339
SeqEyes : An Open‐Source Toolbox for Synchronized Waveform/Trajectory Visualization in Pulseq
Pulseq enables vendor‐neutral description of MRI pulse sequences in human‐readable .seq files and is widely used for sequence development and sharing. During design and debugging, rapid evaluation of sequence timing across RF pulses, gradient waveforms, and ADC events is essential. This is particularly challenging for non‐Cartesian acquisitions, where waveform timing does not readily reveal the underlying k ‐space trajectory. Existing tools, however, provide limited interactive capabilities for this task. Here, we introduce SeqEyes, an interactive viewer for Pulseq .seq files tailored for efficient sequence analysis. The software parses .seq files to provide synchronized visualization of RF, gradient, and ADC waveforms alongside their corresponding k ‐space trajectories. This establishes a direct link between sequence structure and sampling behavior within a single interface. The tool supports interactive navigation across time, TRs, and sequence blocks, as well as event‐level timing verification, visualization of Pulseq extensions, and diagnostic overlays. SeqEyes features a graphical user interface, complemented by command‐line, Python, and MATLAB interfaces for integration into existing research workflows. By unifying waveform and trajectory visualizations, this open‐source toolbox optimizes the routine validation of Pulseq sequences, ultimately reducing the barrier to developing and sharing complex MRI acquisitions.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 12 (25730436) , 587-600
Ozone Cues Mitigate Reflected Downwelling Radiance in LWIR Absorption-Based Ranging
Passive long-wave infrared (LWIR) absorption-based ranging relies on atmospheric absorption to estimate distances to objects from their emitted thermal radiation. First demonstrated decades ago for objects much hotter than the air and recently extended to scenes with low temperature variations, this ranging has depended on reflected radiance being negligible. Downwelling radiance is especially problematic, sometimes causing large inaccuracies. In two new ranging methods, we use characteristic features from ozone absorption to estimate the contribution of reflected downwelling radiance. The quadspectral method gives a simple closed-form range estimate from four narrowband measurements, two at a water vapor absorption line and two at an ozone absorption line. The hyperspectral method uses a broader spectral range to improve accuracy while also providing estimates of temperature, emissivity profiles, and contributions of downwelling from a collection of zenith angles. Experimental results demonstrate improved ranging accuracy, in one case reducing error from over 100 m when reflected light is not modeled to 6.8 m with the quadspectral method and 1.2 m with the hyperspectral method.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 12 (25730436) , 587-600
Ozone Cues Mitigate Reflected Downwelling Radiance in LWIR Absorption-Based Ranging
Passive long-wave infrared (LWIR) absorption-based ranging relies on atmospheric absorption to estimate distances to objects from their emitted thermal radiation. First demonstrated decades ago for objects much hotter than the air and recently extended to scenes with low temperature variations, this ranging has depended on reflected radiance being negligible. Downwelling radiance is especially problematic, sometimes causing large inaccuracies. In two new ranging methods, we use characteristic features from ozone absorption to estimate the contribution of reflected downwelling radiance. The quadspectral method gives a simple closed-form range estimate from four narrowband measurements, two at a water vapor absorption line and two at an ozone absorption line. The hyperspectral method uses a broader spectral range to improve accuracy while also providing estimates of temperature, emissivity profiles, and contributions of downwelling from a collection of zenith angles. Experimental results demonstrate improved ranging accuracy, in one case reducing error from over 100 m when reflected light is not modeled to 6.8 m with the quadspectral method and 1.2 m with the hyperspectral method.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 47 (5) , 4044-4060
Absorption-Based, Passive Range Imaging From Hyperspectral Thermal Measurements
Passive hyperspectral longwave infrared measurements are remarkably informative about the surroundings. Remote object material and temperature determine the spectrum of thermal radiance, and range, air temperature, and gas concentrations determine how this spectrum is modified by propagation to the sensor. We introduce a passive range imaging method based on computationally separating these phenomena. Previous methods assume hot and highly emitting objects; ranging is more challenging when objects' temperatures do not deviate greatly from air temperature. Our method jointly estimates range and intrinsic object properties, with explicit consideration of air emission, though reflected light is assumed negligible. Inversion being underdetermined is mitigated by using a parametric model of atmospheric absorption and regularizing for smooth emissivity estimates. To assess where our estimate is likely accurate, we introduce a technique to detect which scene pixels are significantly influenced by reflected downwelling. Monte Carlo simulations demonstrate the importance of regularization, temperature differentials, and availability of many spectral bands. We apply our method to longwave infrared (8–13 $\mu$ m) hyperspectral image data acquired from natural scenes with no active illumination. Range features from 15 m to 150 m are recovered, with good qualitative match to lidar data for pixels classified as having negligible reflected downwelling.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 47 (5) , 4044-4060
Absorption-Based, Passive Range Imaging From Hyperspectral Thermal Measurements
Passive hyperspectral longwave infrared measurements are remarkably informative about the surroundings. Remote object material and temperature determine the spectrum of thermal radiance, and range, air temperature, and gas concentrations determine how this spectrum is modified by propagation to the sensor. We introduce a passive range imaging method based on computationally separating these phenomena. Previous methods assume hot and highly emitting objects; ranging is more challenging when objects' temperatures do not deviate greatly from air temperature. Our method jointly estimates range and intrinsic object properties, with explicit consideration of air emission, though reflected light is assumed negligible. Inversion being underdetermined is mitigated by using a parametric model of atmospheric absorption and regularizing for smooth emissivity estimates. To assess where our estimate is likely accurate, we introduce a technique to detect which scene pixels are significantly influenced by reflected downwelling. Monte Carlo simulations demonstrate the importance of regularization, temperature differentials, and availability of many spectral bands. We apply our method to longwave infrared (8–13 $\mu$ m) hyperspectral image data acquired from natural scenes with no active illumination. Range features from 15 m to 150 m are recovered, with good qualitative match to lidar data for pixels classified as having negligible reflected downwelling.
- 18 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (1) , 151-166
Absorption-based hyperspectral thermal ranging: performance analyses, optimization, and simulations
The wavelength dependence of atmospheric absorption creates range cues in hyperspectral measurements that can be exploited for passive ranging using only thermal emissions. In this work, we present fundamental limits on absorption-based ranging under a model of known air temperature and wavelength-dependent attenuation coefficient, with object temperature and emissivity unknown; reflected solar and environmental radiance is omitted from our analysis. Fisher information computations illustrate how performance limits depend on atmospheric conditions such as air temperature and humidity; temperature contrast in the scene; spectral resolution of measurement; and distance. These results should prove valuable in sensor system design.
- 18 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (1) , 151-166
Absorption-based hyperspectral thermal ranging: performance analyses, optimization, and simulations
The wavelength dependence of atmospheric absorption creates range cues in hyperspectral measurements that can be exploited for passive ranging using only thermal emissions. In this work, we present fundamental limits on absorption-based ranging under a model of known air temperature and wavelength-dependent attenuation coefficient, with object temperature and emissivity unknown; reflected solar and environmental radiance is omitted from our analysis. Fisher information computations illustrate how performance limits depend on atmospheric conditions such as air temperature and humidity; temperature contrast in the scene; spectral resolution of measurement; and distance. These results should prove valuable in sensor system design.