HHHuiming Huang

Huiming Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huiming Huang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A binocular calibration method based on a coded 1D target for large-field measurement

    by Lei Deng, Guihua Liu, Min Dai, Huiming Huang, Hao Deng, Wei Rao

    To address the practical difficulty of deploying large planar targets in large-field binocular calibration and the insufficient accuracy and robustness of existing calibration methods based on one-dimensional (1D) targets, a binocular calibration method based on a coded 1D target is proposed. First, an effective matched observation set is constructed through coded point centre extraction, cross-view matching, and epipolar distance screening, and is then divided into an accuracy evaluation observation set and a candidate calibration observation set. Then, during each single calibration process, a calibration subset is randomly sampled from the candidate calibration observation set, and the initial binocular parameters are obtained through fundamental matrix estimation and refinement, initialisation based on the physical parameters of the cameras, essential matrix decomposition, and rod length constraints. The optimisation variables are further released stage by stage during optimisation, enabling the optimisation of intrinsic, extrinsic, and distortion parameters while suppressing interference from parameter coupling. Finally, multiple single calibration results are evaluated in a unified manner on the fixed accuracy evaluation observation set, and the final calibration parameters are selected according to the minimum error criterion. Experimental results show that the mean reprojection error and mean absolute error of the proposed method are 0.0277 px and 0.0422 mm, respectively, both of which are lower than those of the comparative methods. The proposed method also maintains stable calibration performance under different object depths and different binocular baseline lengths. When a standard sphere device is reconstructed, the maximum error of the sphere centre distance is 0.117 mm. The proposed method avoids dependence on a large planar target while ensuring calibration accuracy and robustness, thereby providing a technical solution for the calibration of visual measurement and three-dimensional reconstruction systems.

  • Cross-grid laser reconstruction method based on stripe splitting and coarse-to-fine matching

    by Lei Deng, Guihua Liu, Min Dai, Huiming Huang, Hao Deng, Wei Rao, Hua Liu

    In conventional parallel multi-line laser three-dimensional (3D) reconstruction systems, the matching of the laser stripe center point (LSCP) relies on the laser-plane equation. Consequently, the matching accuracy is susceptible to deformations of the laser plane and degrades as the number of laser stripes increases. Moreover, the unidirectional distribution of the laser stripe (LaS) in the image for parallel multi-line setups increases the number of registration steps and prolongs scanning. To address these issues, a trinocular cross-grid laser (CLS) reconstruction method is proposed. First, the trifocal tensor (TFT) and the reference angle for CLS splitting are estimated via system calibration. Next, using the Hessian-matrix normal vector and the minimum directed boundary distance, the CLS is split into unidirectional LaS, and LSCP coarse matching is performed subject to epipolar geometry, disparity, and spatial consistency constraints. Fine matching is then performed via TFT-based point transfer to determine the correct matching triplet from the set of coarse-matched candidates, followed by reconstruction using the left and right cameras. Finally, global registration of local-view point clouds is realized using circular retroreflective markers affixed to the object. Experiments show that, in a 15-line CLS system, the matching rate (MRa) and matching accuracy rate (MAR) reach 97.4561% and 99.1072%, respectively; the reconstruction errors for a two-dimensional (2D) plane and a 3D sphere are less than 0.037 and 0.095 mm, respectively; and the system runs at approximately 12 fps with GPU acceleration. The proposed method alleviates the dependence of multi-line laser reconstruction systems on the laser-plane equation and provides, to our knowledge, a new method for line-laser reconstruction.

  • Multi-line laser 3D reconstruction without light-plane calibration via trinocular spatial consistency and cross reprojection constraints

    by Lei Deng, Min Dai, Guihua Liu, Hao Deng, Huiming Huang

    To address the problem that conventional multi-line laser three-dimensional (3D) reconstruction methods depend on a calibrated laser plane to match and reconstruct laser stripe centre point (LSCP), are susceptible to calibration errors and laser plane deformation, and experience declining reconstruction accuracy as the number of laser stripes increases, a multi-line laser reconstruction method that does not require laser plane calibration is proposed, based on trinocular spatial consistency (SC) and cross reprojection constraints. The method first obtains a coarse set of LSCP triplets through trinocular SC and then the correct matching triplet is selected using cross reprojection constraints. Once accurate trinocular correspondences are established, initial 3D coordinates of each LSCP are computed by stereo triangulation between the left and right cameras, after which a nonlinear optimization model is constructed from the trinocular reprojection error and iteratively solved to improve 3D point accuracy. Rigid transformation matrices determined from preset circular markers are finally used to register the local point clouds to the global coordinate system, completing the reconstruction of the measured object. Experiments show that the proposed method attains the LSCP matching accuracy (LMA) of 99.01% and the LSCP matching recall LMR of 96.10%. When reconstructing a standard sphere apparatus, the maximum absolute deviations in sphere diameter and centre-to-centre distance are 0.111 mm and 0.166 mm, respectively. On an 11-line system, the algorithm averages 57.327 ms per frame. In deployment, the trade-off between accuracy and speed can be tuned to meet application requirements. Robustness tests further show that the method is compatible with hardware configurations featuring different baseline lengths, camera convergence angles and lens focal lengths. The method reduces the dependence of multi-line laser reconstruction systems on a laser plane and provides a technical solution for multi-line laser measurement.


  • Open Access

    The Joint Calibration Method of Multi-line Laser and Tracking System based on Conjugate Gradient Iteration

    by Huiming Huang, Guihua Liu, Jiajia Liu, Xueyin Liu, Lei Deng, Tao Song, Fuping Qin

    The multi-line laser 3D reconstruction system mainly relies on marking points to acquire 3D data. To simplify the acquisition of 3D data for objects, we use a binocular tracking method to achieve unmarked point stitching of the multi-line laser reconstructed 3D data. The key challenge with this system is the joint calibration between the multi-line laser system and the tracking ball cage. Traditionally, planar calibration plates are used for calibration. However, due to the extensive calibration field, the production of large calibration plates incurs high costs and compromises machining accuracy. As a result, significant joint calibration errors occur between the tracking ball and the multi-line laser system, making high-precision calibration impossible. To solve these problems, an iterative method based on multi-position attitude and conjugate gradient is proposed to achieve high-precision joint calibration. A simple and convenient cross pole with multiple coding points is used as a calibrator. The 3D data of these coding points are determined beforehand using a coordinate measuring machine (CMM). First, the internal and external parameters of the binocular tracking system are calibrated using this cross pole. During the joint calibration process, in which both the multi-line laser system and the tracking ball cage are involved, the cross pole is imaged at different positions simultaneously with the binocular tracking system and the multi-line laser system. This allows us to determine the positions and orientations of both systems relative to each other and relative to the cross pole. The transformation relationship between the multi-line laser system and the tracking ball cage is calibrated using an iterative conjugate gradient optimization algorithm based on these positions and orientations, which completes the entire system calibration and eventually achieves three-dimensional reconstruction of the unmarked points. Compared to conventional planar calibration plate-based methods, our proposed approach requires only one cross pole to perform two crucial calibration steps, improving the joint calibration accuracy. While the final reconstruction accuracy of conventional methods is about 0.1 mm, our proposed method can achieve an accuracy of about 0.02 mm.

  • Open Access

    Spatial quadric calibration method for multi-line laser based on diffractive optical element

    by Huiming Huang, Guihua Liu, Canjun Xiao, Lei Deng, Yunxin Gong, Tao Song, Fuping Qin

    The traditional multi-line laser calibration method relies primarily on calibrating the spatial plane equations of multiple laser lines and reconstructing the multi-line laser in three dimensions through the plane equation and camera parameters. In traditional methods, the multi-line laser is projected as a straight line by default, but in reality, the laser line projected by the multi-line laser is not a plane due to the Diffractive Optical Element (DOE). Instead, it is a surface with a certain curvature in space. During the production process, the multi-line laser experiences significant distortion because of the DOE projecting at a large angle. Consequently, if traditional methods are used, accurate calibration of the multi-line laser cannot be achieved. To address this issue, this paper introduces a new calibration algorithm for multi-line laser based on a spatial quadric equation. By calibrating the spatial quadric equation of the multi-line laser, the spatial characteristics of the laser can be accurately captured. The algorithm involves projecting a crossed 7-line laser onto a calibration plate and changing the position of the calibration plate while capturing images. This allows for obtaining the spatial three-dimensional coordinates of each laser line in the camera coordinate system. Next, spatial quadric equations are fitted for each laser line based on the three-dimensional coordinates. Finally, 3D reconstruction is performed using the quadratic surface parameters of the multi-line laser and camera parameters. The results from 3D reconstruction demonstrate that, compared to traditional laser calibration methods based on planes, the proposed algorithm achieves higher calibration accuracy. It also improves the number of successful binocular multi-line laser matches and overall accuracy.