Meinhard Reinert Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Meinhard Reinert Hansen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Anne Heltborg
Department of Emergency Medicine, University Hospital of Southern Denmark, 6200 Aabenraa, Denmark
1 shared publication - Camilla Stræde Spile
Department of Radiology, Odense University Hospital, 5000 Odense, Denmark
1 shared publication - Christian Backer Mogensen
Department of Emergency Medicine, University hospital of Southern Denmark, Aabenraa, Denmark
1 shared publication - Christian Borbjerg Laursen
Department of Respiratory Medicine, Odense University Hospital, Odense, Denmark
1 shared publication - Frida Poppius Kaldan
University of Southern Denmark Faculty of Health Sciences, Odense, Syddanmark, Denmark
1 shared publication - Helene Skjøt-Arkil
Department of Regional Health Research, University of Southern Denmark, Odense, Denmark
1 shared publication
Latest Publications
- Open Access
- 30 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1921
Handheld Ultrasound Devices Used by Newly Certified Operators for Pneumonia in the Emergency Department—A Diagnostic Accuracy Study
The diagnostic accuracy of handheld ultrasound (HHUS) devices operated by newly certified operators for pneumonia is unknown. This multicenter diagnostic accuracy study included patients prospectively suspected of pneumonia from February 2021 to February 2022 in four emergency departments. The index test was a 14-zone focused lung ultrasound (FLUS) examination, with consolidation with air bronchograms as diagnostic criteria for pneumonia. FLUS examinations were performed by newly certified operators using HHUS. The reference standard was computed tomography (CT) and expert diagnosis using all medical records. The sensitivity and specificity of FLUS and chest X-ray (CXR) were compared using McNemar’s test. Of the 324 scanned patients, 212 (65%) had pneumonia, according to the expert diagnosis. FLUS had a sensitivity of 31% (95% CI 26–36) and a specificity of 82% (95% CI 78–86) compared with the experts’ diagnosis. Compared with CT, FLUS had a sensitivity of 32% (95% CI 27–37) and specificity of 81% (95% CI 77–85). CXR had a sensitivity of 66% (95% CI 61–72) and a specificity of 76% (95% CI 71–81) compared with the experts’ diagnosis. Compared with CT, CXR had a sensitivity of 69% (95% CI 63–74) and a specificity of 68% (95% CI 62–72). Compared with the experts’ diagnosis and CT diagnosis, FLUS performed by newly certified operators using HHUS devices had a significantly lower sensitivity for pneumonia when compared to CXR (p < 0.001). FLUS had a significantly higher specificity than CXR using CT diagnosis as a reference standard (p = 0.02). HHUS exhibited low sensitivity for pneumonia when used by newly certified operators.
- 30 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1921
Open AccessHandheld Ultrasound Devices Used by Newly Certified Operators for Pneumonia in the Emergency Department—A Diagnostic Accuracy Study
The diagnostic accuracy of handheld ultrasound (HHUS) devices operated by newly certified operators for pneumonia is unknown. This multicenter diagnostic accuracy study included patients prospectively suspected of pneumonia from February 2021 to February 2022 in four emergency departments. The index test was a 14-zone focused lung ultrasound (FLUS) examination, with consolidation with air bronchograms as diagnostic criteria for pneumonia. FLUS examinations were performed by newly certified operators using HHUS. The reference standard was computed tomography (CT) and expert diagnosis using all medical records. The sensitivity and specificity of FLUS and chest X-ray (CXR) were compared using McNemar’s test. Of the 324 scanned patients, 212 (65%) had pneumonia, according to the expert diagnosis. FLUS had a sensitivity of 31% (95% CI 26–36) and a specificity of 82% (95% CI 78–86) compared with the experts’ diagnosis. Compared with CT, FLUS had a sensitivity of 32% (95% CI 27–37) and specificity of 81% (95% CI 77–85). CXR had a sensitivity of 66% (95% CI 61–72) and a specificity of 76% (95% CI 71–81) compared with the experts’ diagnosis. Compared with CT, CXR had a sensitivity of 69% (95% CI 63–74) and a specificity of 68% (95% CI 62–72). Compared with the experts’ diagnosis and CT diagnosis, FLUS performed by newly certified operators using HHUS devices had a significantly lower sensitivity for pneumonia when compared to CXR (p < 0.001). FLUS had a significantly higher specificity than CXR using CT diagnosis as a reference standard (p = 0.02). HHUS exhibited low sensitivity for pneumonia when used by newly certified operators.
- Open Access
- 8 March 2024
- Published by MDPI AG in Journal of Imaging
- Vol. 10 (3) , 66
Magnetic Resonance Imaging as a Diagnostic Tool for Ilio-Femoro-Caval Deep Venous Thrombosis
This study aimed to test the accuracy of a magnetic resonance imaging (MRI)-based method to detect and characterise deep venous thrombosis (DVT) in the ilio-femoro-caval veins. Patients with verified DVT in the lower extremities with extension of the thrombi to the iliac veins, who were suitable for catheter-based venous thrombolysis, were included in this study. Before the intervention, magnetic resonance venography (MRV) was performed, and the ilio-femoro-caval veins were independently evaluated for normal appearance, stenosis, and occlusion by two single-blinded observers. The same procedure was used to evaluate digital subtraction phlebography (DSP), considered to be the gold standard, which made it possible to compare the results. A total of 123 patients were included for MRV and DSP, resulting in 246 image sets to be analysed. In total, 496 segments were analysed for occlusion, stenosis, or normal appearance. The highest sensitivity compared occlusion with either normal or stenosis (0.98) in MRV, while the lowest was found between stenosis and normal (0.84). Specificity varied from 0.59 (stenosis >< occlusion) to 0.94 (occlusion >< normal). The Kappa statistic was calculated as a measure of inter-observer agreement. The kappa value for MRV was 0.91 and for DSP, 0.80. In conclusion, MRV represents a sensitive method to analyse DVT in the pelvis veins with advantages such as no radiation and contrast and the possibility to investigate the anatomical relationship in the area.
- 8 March 2024
- Published by MDPI AG in Journal of Imaging
- Vol. 10 (3) , 66
Open AccessMagnetic Resonance Imaging as a Diagnostic Tool for Ilio-Femoro-Caval Deep Venous Thrombosis
This study aimed to test the accuracy of a magnetic resonance imaging (MRI)-based method to detect and characterise deep venous thrombosis (DVT) in the ilio-femoro-caval veins. Patients with verified DVT in the lower extremities with extension of the thrombi to the iliac veins, who were suitable for catheter-based venous thrombolysis, were included in this study. Before the intervention, magnetic resonance venography (MRV) was performed, and the ilio-femoro-caval veins were independently evaluated for normal appearance, stenosis, and occlusion by two single-blinded observers. The same procedure was used to evaluate digital subtraction phlebography (DSP), considered to be the gold standard, which made it possible to compare the results. A total of 123 patients were included for MRV and DSP, resulting in 246 image sets to be analysed. In total, 496 segments were analysed for occlusion, stenosis, or normal appearance. The highest sensitivity compared occlusion with either normal or stenosis (0.98) in MRV, while the lowest was found between stenosis and normal (0.84). Specificity varied from 0.59 (stenosis >< occlusion) to 0.94 (occlusion >< normal). The Kappa statistic was calculated as a measure of inter-observer agreement. The kappa value for MRV was 0.91 and for DSP, 0.80. In conclusion, MRV represents a sensitive method to analyse DVT in the pelvis veins with advantages such as no radiation and contrast and the possibility to investigate the anatomical relationship in the area.