Anirban Kolay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anirban Kolay has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Amitesh Kumar
National Institute of Technology Patna
4 shared publications - Subrata Majumder
Department of Applied Physics and Materials Engineering, National Institute of Technology 1 , Patna 800005
2 shared publications Deepti
1 shared publication- Deepti
Department of Physics, National Institute of Technology, Patna, INDIA
1 shared publication
Latest Publications
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Materials for Electron Devices
- Vol. 2, 126-134
Device Engineering of a Novel Label-Free Carbon and Double Gate-Based Sensor for PoC Diagnosis of Neural Diseases Through Dopamine and Serotonin Sensing
The manuscript discusses low-cost, rapid and diagnostic detection of dopamine and serotonin, whose abnormal levels lead to numerous neurological disabilities like Schizophrenia, Parkinson's disease, Huntington's disease and Alzheimer's disease. In this present work, simulation of three different proposed structures has been demonstrated for the detection of biomolecules: (a) amorphous carbon sensing material-based dopamine detection sensor, (b) graphite sensing material-based serotonin detection sensor and (c) double-gate FET structure for dopamine detection sensor. The cavities of amorphous carbon-based and graphite-based biosensors are expanded to 20 nm for better sensitivity. The amorphous carbon-based and graphite-based biosensors can detect dopamine and serotonin concentrations as low as 1.33 fM, respectively. In previous literature, an experimental electrochemical study has been done using 3-electrode set-up using amorphous carbon coated pencil graphite electrode as working electrode for dopamine detection. The results of an experimental electrochemical study are validated with the suggested amorphous carbon-based and graphite-based biosensors' sensitivity to various dopamine and serotonin concentrations. The sensing materials employed in this study: amorphous carbon and graphite are both readily available and cost-effective. Additionally, from the discussion it has been observed that the proposed devices exhibit significantly different sensitivity levels compared to existing designs. A novel double gate FET structure device has been also proposed for detecting dopamine by introducing cavities in Hafnium dioxide so that biomolecules present in those cavities can be sensed by observing change in the drain current. The previous published work has been compared to the suggested detection method. Dopamine and serotonin are the neurotransmitters that are essential to the human body's neurological, hormonal and renal systems, hence these proposed approaches can be utilized for point of care diagnosis
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Materials for Electron Devices
- Vol. 2, 126-134
Device Engineering of a Novel Label-Free Carbon and Double Gate-Based Sensor for PoC Diagnosis of Neural Diseases Through Dopamine and Serotonin Sensing
The manuscript discusses low-cost, rapid and diagnostic detection of dopamine and serotonin, whose abnormal levels lead to numerous neurological disabilities like Schizophrenia, Parkinson's disease, Huntington's disease and Alzheimer's disease. In this present work, simulation of three different proposed structures has been demonstrated for the detection of biomolecules: (a) amorphous carbon sensing material-based dopamine detection sensor, (b) graphite sensing material-based serotonin detection sensor and (c) double-gate FET structure for dopamine detection sensor. The cavities of amorphous carbon-based and graphite-based biosensors are expanded to 20 nm for better sensitivity. The amorphous carbon-based and graphite-based biosensors can detect dopamine and serotonin concentrations as low as 1.33 fM, respectively. In previous literature, an experimental electrochemical study has been done using 3-electrode set-up using amorphous carbon coated pencil graphite electrode as working electrode for dopamine detection. The results of an experimental electrochemical study are validated with the suggested amorphous carbon-based and graphite-based biosensors' sensitivity to various dopamine and serotonin concentrations. The sensing materials employed in this study: amorphous carbon and graphite are both readily available and cost-effective. Additionally, from the discussion it has been observed that the proposed devices exhibit significantly different sensitivity levels compared to existing designs. A novel double gate FET structure device has been also proposed for detecting dopamine by introducing cavities in Hafnium dioxide so that biomolecules present in those cavities can be sensed by observing change in the drain current. The previous published work has been compared to the suggested detection method. Dopamine and serotonin are the neurotransmitters that are essential to the human body's neurological, hormonal and renal systems, hence these proposed approaches can be utilized for point of care diagnosis
- 11 January 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 136 (1) , 104282
Low-cost graphite and double-gate FET-based label-free biosensor for dopamine sensing to detect neural diseases
The manuscript proposes biosensors for detecting different concentrations of neurotransmitters named dopamine, which have a critical role in the human body's neurological, hormonal, and renal systems. In this work, the primary focus is to detect dopamine, whose disorder levels cause many neurological disabilities such as Alzheimer's and Parkinson's disease. In the present work, the simulation of two different structures has been studies: a) a graphite-based structure and b) a double gate TFET structure for detecting dopamine using TCAD Silvaco software. The proposed device utilizes a graphite-based structure with respective work functions of the used materials and studies the change in ON current (ION sensing factor is calculated for simulation study for VGS = 0.8 V). The cavity is increased to 800 µm for graphite-based biosensors for improved sensitivity. The graphite-based biosensors can detect up to 13.3 nM concentration of dopamine. Experimental electrochemical analysis results verify the proposed graphite-based biosensors' sensitivity for different dopamine concentrations. Another double gate field effect transistor (FET) biosensor has also been investigated for the detection of dopamine. The effective dielectric constant has been calculated using Bruggeman's model to check the sensitivity of double gate FET-based sensors for varying dopamine and uric acid concentrations. The sensitivity is increased with the increase of dopamine concentration percentage.
- 11 January 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 136 (1) , 104282
Low-cost graphite and double-gate FET-based label-free biosensor for dopamine sensing to detect neural diseases
The manuscript proposes biosensors for detecting different concentrations of neurotransmitters named dopamine, which have a critical role in the human body's neurological, hormonal, and renal systems. In this work, the primary focus is to detect dopamine, whose disorder levels cause many neurological disabilities such as Alzheimer's and Parkinson's disease. In the present work, the simulation of two different structures has been studies: a) a graphite-based structure and b) a double gate TFET structure for detecting dopamine using TCAD Silvaco software. The proposed device utilizes a graphite-based structure with respective work functions of the used materials and studies the change in ON current (ION sensing factor is calculated for simulation study for VGS = 0.8 V). The cavity is increased to 800 µm for graphite-based biosensors for improved sensitivity. The graphite-based biosensors can detect up to 13.3 nM concentration of dopamine. Experimental electrochemical analysis results verify the proposed graphite-based biosensors' sensitivity for different dopamine concentrations. Another double gate field effect transistor (FET) biosensor has also been investigated for the detection of dopamine. The effective dielectric constant has been calculated using Bruggeman's model to check the sensitivity of double gate FET-based sensors for varying dopamine and uric acid concentrations. The sensitivity is increased with the increase of dopamine concentration percentage.
- 27 February 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 125 (1) , 104133
A Novel Liver Cancer POC Diagnostic Detection Technique by a Gate-engineered Source-extended TFET Device
This work reports a novel POC diagnostic technique to identify the cancerous liver cell lines by designing a Source-Extended (SE) Tunnel Field Effect Transistor (TFET) having a Single-Gate (SG) with Single-Metal (SM) and Dual-Metal (DM) structure. The proposed structures have been equipped with nanocavities by trenching the gate oxide layer where the needle biopsy obtained liver sample has been immobilized. The detection is based on the difference in drain current and the ratio of the proposed device's ON and OFF state currents, which has been evaluated by obtaining the sensitivities. The cancerous and non-cancerous liver cell lines possess different dielectric properties in high frequencies ranging from 100 MHz to 5 GHz, affecting the cavity region's effective capacitances. The change in the dielectric constant of the specimen at 900 MHz has been considered which results in the change in device drain current and device performance. Various parameters of the device, like the adhesive layer in the cavity region, the material of the gate, the length of the cavities, and the orientation of the cavities, have been modified to observe the performance. The total work has been done in the simulation environment, which includes the study considering the different proportions of cancerous and non-cancerous cells in a particular specimen. A comparative analysis has been made between the performance of the proposed SM and DM gate structure. The proposed detection method has been compared with the existing methods reported in the literature. The proposed method can be considered a novel technique and can be implemented as a point of care (POC) diagnostic to detect whether the specimen liver cell line is cancerous.
- 27 February 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 125 (1) , 104133
A Novel Liver Cancer POC Diagnostic Detection Technique by a Gate-engineered Source-extended TFET Device
This work reports a novel POC diagnostic technique to identify the cancerous liver cell lines by designing a Source-Extended (SE) Tunnel Field Effect Transistor (TFET) having a Single-Gate (SG) with Single-Metal (SM) and Dual-Metal (DM) structure. The proposed structures have been equipped with nanocavities by trenching the gate oxide layer where the needle biopsy obtained liver sample has been immobilized. The detection is based on the difference in drain current and the ratio of the proposed device's ON and OFF state currents, which has been evaluated by obtaining the sensitivities. The cancerous and non-cancerous liver cell lines possess different dielectric properties in high frequencies ranging from 100 MHz to 5 GHz, affecting the cavity region's effective capacitances. The change in the dielectric constant of the specimen at 900 MHz has been considered which results in the change in device drain current and device performance. Various parameters of the device, like the adhesive layer in the cavity region, the material of the gate, the length of the cavities, and the orientation of the cavities, have been modified to observe the performance. The total work has been done in the simulation environment, which includes the study considering the different proportions of cancerous and non-cancerous cells in a particular specimen. A comparative analysis has been made between the performance of the proposed SM and DM gate structure. The proposed detection method has been compared with the existing methods reported in the literature. The proposed method can be considered a novel technique and can be implemented as a point of care (POC) diagnostic to detect whether the specimen liver cell line is cancerous.