Yan Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yan Xu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ai-Hua Zhang
Department of Nephrology, Xuanwu Hospital, Capital Medical University
1 shared publication - Junfeng Xu
School of Computer and Cyber Sciences, Communication University of China, Beijing, China
1 shared publication - Kunpeng Wang
School of Mechatronic Engineering Shanghai University 200444 Shanghai China
1 shared publication - LeiYun Wu
Department of Nephrology, Xuanwu Hospital Capital Medical University, Beijing, China
1 shared publication Qi Pang
Department of Nephrology, Xuanwu Hospital Capital Medical University, Beijing, China
1 shared publication- Weiguo Lin
Communication University of China
1 shared publication
Latest Publications
- Open Access
- 7 August 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (32) , e50071
Risk analysis and warning model of post-noncardiac surgery acute kidney injury: A retrospective observational study
Postoperative acute kidney injury (PO-AKI) following noncardiac surgery remains a major clinical challenge, for which effective early warning models are still lacking. This study aimed to identify risk factors for noncardiac PO-AKI and to develop and validate a practical early warning model based on readily available clinical parameters across multiple surgical subspecialties. In this study, large-scale data from noncardiac surgical patients were extracted from the electronic medical record system of Xuanwu Hospital to analyze risk factors. Subsequently, an early warning model for PO-AKI was developed by integrating logistic regression (LR) and deep learning (DL) approaches. Internal and external validations were performed to assess model performance. A total of 19,152 patients were included in the analysis. Eleven independent risk variables were identified using LR, including age, surgical department, prolonged operation duration, contrast agent exposure, elevated serum creatinine, proteinuria, hemoglobin reduction, elevated fasting blood glucose, serum potassium abnormalities, neutrophil-to-lymphocyte ratio, and D-dimer levels. A corresponding risk score was subsequently constructed. The receiver operating characteristic analysis demonstrated areas under the curve (AUCs) of 0.7679 for the LR model and 0.7578 for the derived risk score. In the validation cohort, the AUCs were 0.7856 and 0.7122, respectively. The DL model further improved predictive performance, achieving AUCs of 0.97 and 0.93 in the validation and test sets, respectively. Precision–recall analysis showed area under the precision–recall curve values of 0.96 and 0.74, with corresponding F 1 scores of 0.945 and 0.897. Big data analysis revealed an overall incidence of PO-AKI after noncardiac surgery of 3.69%. A robust early warning model incorporating 11 clinically practical parameters was developed. The integration of LR and DL approaches improved predictive performance while maintaining interpretability.
- 7 August 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (32) , e50071
Open AccessRisk analysis and warning model of post-noncardiac surgery acute kidney injury: A retrospective observational study
Postoperative acute kidney injury (PO-AKI) following noncardiac surgery remains a major clinical challenge, for which effective early warning models are still lacking. This study aimed to identify risk factors for noncardiac PO-AKI and to develop and validate a practical early warning model based on readily available clinical parameters across multiple surgical subspecialties. In this study, large-scale data from noncardiac surgical patients were extracted from the electronic medical record system of Xuanwu Hospital to analyze risk factors. Subsequently, an early warning model for PO-AKI was developed by integrating logistic regression (LR) and deep learning (DL) approaches. Internal and external validations were performed to assess model performance. A total of 19,152 patients were included in the analysis. Eleven independent risk variables were identified using LR, including age, surgical department, prolonged operation duration, contrast agent exposure, elevated serum creatinine, proteinuria, hemoglobin reduction, elevated fasting blood glucose, serum potassium abnormalities, neutrophil-to-lymphocyte ratio, and D-dimer levels. A corresponding risk score was subsequently constructed. The receiver operating characteristic analysis demonstrated areas under the curve (AUCs) of 0.7679 for the LR model and 0.7578 for the derived risk score. In the validation cohort, the AUCs were 0.7856 and 0.7122, respectively. The DL model further improved predictive performance, achieving AUCs of 0.97 and 0.93 in the validation and test sets, respectively. Precision–recall analysis showed area under the precision–recall curve values of 0.96 and 0.74, with corresponding F 1 scores of 0.945 and 0.897. Big data analysis revealed an overall incidence of PO-AKI after noncardiac surgery of 3.69%. A robust early warning model incorporating 11 clinically practical parameters was developed. The integration of LR and DL approaches improved predictive performance while maintaining interpretability.
- Open Access
- 21 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Leveraging vision transformers and entropy-based attention for accurate micro-expression recognition
Micro-expressions are difficult to fake and inherently truthful, making micro-expression recognition technology widely applicable across various domains. With the development of artificial intelligence, the accuracy and efficiency of micro-expression recognition systems have been significantly improved. However, the short duration and subtle facial movement changes present significant challenges to real-time recognition and accuracy. To address these issues, this paper proposes a novel micro-expression recognition method based on the Vision Transformer. First, a new model called HTNet with LAPE (hierarchical transformer network with learnable absolute position embedding) is introduced to improve the model’s capacity for capturing subtle facial features, thereby enhancing the accuracy of micro-expression recognition. Second, an entropy-based selection agent attention is proposed to reduce the model parameters and computational effort while preserving its learning capability. Finally, a diffusion model is utilized for data augmentation to expand the micro-expression sample size, further enhancing the model’s generalization, accuracy, and robustness. Extensive experiments conducted on multiple datasets validate the framework’s effectiveness and highlight its potential in real-world applications.
- 21 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessLeveraging vision transformers and entropy-based attention for accurate micro-expression recognition
Micro-expressions are difficult to fake and inherently truthful, making micro-expression recognition technology widely applicable across various domains. With the development of artificial intelligence, the accuracy and efficiency of micro-expression recognition systems have been significantly improved. However, the short duration and subtle facial movement changes present significant challenges to real-time recognition and accuracy. To address these issues, this paper proposes a novel micro-expression recognition method based on the Vision Transformer. First, a new model called HTNet with LAPE (hierarchical transformer network with learnable absolute position embedding) is introduced to improve the model’s capacity for capturing subtle facial features, thereby enhancing the accuracy of micro-expression recognition. Second, an entropy-based selection agent attention is proposed to reduce the model parameters and computational effort while preserving its learning capability. Finally, a diffusion model is utilized for data augmentation to expand the micro-expression sample size, further enhancing the model’s generalization, accuracy, and robustness. Extensive experiments conducted on multiple datasets validate the framework’s effectiveness and highlight its potential in real-world applications.
- Open Access
- 10 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Friction injury of the central vein caused by catheter for hemodialysis: an in vitro study
Vascular injury such as central venous stenosis (CVS) is a common complication in hemodialysis patients with central venous catheters (CVCs), yet the impact of the microstructure and partial physic characteristics of catheter surface on the chronic injury of central vein has not been elucidated. In this study, the microscopic morphology of tips and bodies of six different brands of polyurethane CVCs was observed and their roughness was assessed. Subsequently, an in vitro model was established to measure the coefficients of friction (COF) between CVCs (tips and bodies) and the vena cava intima of Japanese rabbits under the same condition in a linear reciprocating mode, and changes in the intima of vessels after friction were observed. The study found that there was a significant variation in surface roughness among different brands of CVCs (tips P < 0.001, bodies P = 0.02), and the COF was positively correlated with the catheter surface roughness (tips P = 0.005, R = 0.945, bodies P = 0.01, R = 0.909). Besides, the endovascular roughness increased after friction. These findings suggest that the high roughness surface of CVCs may cause chronic mechanical friction injury to the central venous intima, which is one of the potential factors leading to CVS or occlusion. This provides a breakthrough for reducing complications, improving patient prognosis, and advancing catheter surface lubrication technology.
- 10 March 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessFriction injury of the central vein caused by catheter for hemodialysis: an in vitro study
Vascular injury such as central venous stenosis (CVS) is a common complication in hemodialysis patients with central venous catheters (CVCs), yet the impact of the microstructure and partial physic characteristics of catheter surface on the chronic injury of central vein has not been elucidated. In this study, the microscopic morphology of tips and bodies of six different brands of polyurethane CVCs was observed and their roughness was assessed. Subsequently, an in vitro model was established to measure the coefficients of friction (COF) between CVCs (tips and bodies) and the vena cava intima of Japanese rabbits under the same condition in a linear reciprocating mode, and changes in the intima of vessels after friction were observed. The study found that there was a significant variation in surface roughness among different brands of CVCs (tips P < 0.001, bodies P = 0.02), and the COF was positively correlated with the catheter surface roughness (tips P = 0.005, R = 0.945, bodies P = 0.01, R = 0.909). Besides, the endovascular roughness increased after friction. These findings suggest that the high roughness surface of CVCs may cause chronic mechanical friction injury to the central venous intima, which is one of the potential factors leading to CVS or occlusion. This provides a breakthrough for reducing complications, improving patient prognosis, and advancing catheter surface lubrication technology.