M. O. Hanson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M. O. Hanson has a total of 200 co-authors. Here are the top co-authors by number of shared publications:
- Clayton Edward Myers
Commonwealth Fusion Systems , Devens, Massachusetts 01434
5 shared publications - Ella Fox-Widdows
Commonwealth Fusion Systems , Devens, Massachusetts 01434
5 shared publications - Matthew L. Reinke
Commonwealth Fusion Systems , Devens, Massachusetts 01434
5 shared publications R. Kulchy
Commonwealth Fusion Systems , Devens, Massachusetts 01434
5 shared publications- Adam Q. Kuang
Commonwealth Fusion Systems
4 shared publications J. Witham
Commonwealth Fusion Systems , Devens, Massachusetts 01434
4 shared publications
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Overview of the Langmuir probe and current shunt diagnostics on the SPARC tokamak
To enable real-time control, explore high-field plasma physics, and validate the design of the ARC power plant, SPARC will be equipped with a comprehensive suite of plasma diagnostics. Among these are electrical probe diagnostics integrated into plasma-facing components and attached to the vacuum vessel, including 54 Langmuir probes and 44 current shunt sensors. Main chamber Langmuir probes are tightly integrated into the plasma-facing components and will measure edge plasma parameters at the midplane and at off-midplane limiters. Embedded halo current shunt sensors provide measurements of the halo current width along the off-midplane limiters and share many components with the off-midplane Langmuir probe designs to simplify the interface with the first wall. Divertor Langmuir probes are limited to the X-point target chamber to be used for the SPARC advanced divertor mission. Poloidal current shunts are mounted to the vacuum vessel wall around the divertor for dissipative divertor control. Verified designs are shown to ensure that the probes will contribute meaningful data and that the probe assemblies have a high chance of surviving SPARC’s harsh electromagnetic and thermal environment, since the maintenance opportunities will be minimal due to limited personnel accessibility in later campaigns. The design of all in-vessel probe assemblies is complete; pre-assembly into the corresponding plasma-facing component assemblies is underway prior to installation into SPARC. This paper summarizes the final system design, describes relevant analysis completed through the final design stage and assembly considerations through first encounters with hardware, and highlights the diagnostic requirements, which motivate Langmuir probe measurements on SPARC.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Overview of the Langmuir probe and current shunt diagnostics on the SPARC tokamak
To enable real-time control, explore high-field plasma physics, and validate the design of the ARC power plant, SPARC will be equipped with a comprehensive suite of plasma diagnostics. Among these are electrical probe diagnostics integrated into plasma-facing components and attached to the vacuum vessel, including 54 Langmuir probes and 44 current shunt sensors. Main chamber Langmuir probes are tightly integrated into the plasma-facing components and will measure edge plasma parameters at the midplane and at off-midplane limiters. Embedded halo current shunt sensors provide measurements of the halo current width along the off-midplane limiters and share many components with the off-midplane Langmuir probe designs to simplify the interface with the first wall. Divertor Langmuir probes are limited to the X-point target chamber to be used for the SPARC advanced divertor mission. Poloidal current shunts are mounted to the vacuum vessel wall around the divertor for dissipative divertor control. Verified designs are shown to ensure that the probes will contribute meaningful data and that the probe assemblies have a high chance of surviving SPARC’s harsh electromagnetic and thermal environment, since the maintenance opportunities will be minimal due to limited personnel accessibility in later campaigns. The design of all in-vessel probe assemblies is complete; pre-assembly into the corresponding plasma-facing component assemblies is underway prior to installation into SPARC. This paper summarizes the final system design, describes relevant analysis completed through the final design stage and assembly considerations through first encounters with hardware, and highlights the diagnostic requirements, which motivate Langmuir probe measurements on SPARC.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessOverview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Development of the neutral gas diagnostic system for neutral pressure measurements and gas analysis on the SPARC tokamak
A suite of plasma diagnostics will be installed on the SPARC tokamak to allow for real-time plasma control, an investigation of high-field tokamak physics, and to de-risk the design of ARC, a compact fusion power plant with the aim to supply electricity to the grid. Among these diagnostics is the neutral gas diagnostics system (NTGS), a set of pressure sensors and gas analyzers used to monitor neutral pressure and gas composition for plasma control, optimization of wall conditioning, and helium ash removal, among other measurement functions linked to operational and scientific research needs. While reliable measurements of neutral pressure and gas composition have been fielded on existing magnetic-confinement fusion devices, SPARC represents a step increase in challenge due to its larger power density, higher field, high vacuum vessel bake temperatures, and higher neutron flux environment, as well as a step decrease in the accessibility for maintenance of in-vessel sensors. Multiple sensor types will be employed to have defense-in-depth and mitigate common failure modes. The NTGS system is currently progressing through final design, working to close out decisions using prototyping and analysis, and then moving on to procuring sensors for assembly and installation on SPARC. This paper outlines the current status of the system design and the diagnostic requirements that motivate neutral gas measurements on SPARC, as well as highlights the planned prototyping activities.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Development of the neutral gas diagnostic system for neutral pressure measurements and gas analysis on the SPARC tokamak
A suite of plasma diagnostics will be installed on the SPARC tokamak to allow for real-time plasma control, an investigation of high-field tokamak physics, and to de-risk the design of ARC, a compact fusion power plant with the aim to supply electricity to the grid. Among these diagnostics is the neutral gas diagnostics system (NTGS), a set of pressure sensors and gas analyzers used to monitor neutral pressure and gas composition for plasma control, optimization of wall conditioning, and helium ash removal, among other measurement functions linked to operational and scientific research needs. While reliable measurements of neutral pressure and gas composition have been fielded on existing magnetic-confinement fusion devices, SPARC represents a step increase in challenge due to its larger power density, higher field, high vacuum vessel bake temperatures, and higher neutron flux environment, as well as a step decrease in the accessibility for maintenance of in-vessel sensors. Multiple sensor types will be employed to have defense-in-depth and mitigate common failure modes. The NTGS system is currently progressing through final design, working to close out decisions using prototyping and analysis, and then moving on to procuring sensors for assembly and installation on SPARC. This paper outlines the current status of the system design and the diagnostic requirements that motivate neutral gas measurements on SPARC, as well as highlights the planned prototyping activities.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Development of a thermal diagnostic system for the SPARC tokamak
The SPARC tokamak will have scrape-off layer parallel heat fluxes on the order of GW/m2. Managing power exhaust of this magnitude will be mandatory for a reactor-scale device. To enable this mission, a thermal diagnostic suite will be deployed to measure the in-vessel structural temperatures to ensure they do not exceed their design limits and to determine the spatial distribution and magnitude of energy deposited onto the first wall. Thermocouples and fiber Bragg gratings have been selected for their environmental compatibility and proven useful on other fusion devices. High-density thermocouple arrays in the divertor will have two spring-loaded thermocouples per divertor target tile, which are being used as calorimeters, and will look to resolve the temperature distribution within the tile due to a swept or static strike point. All systems will need to survive the vacuum vessel bake, set at a minimum plasma facing surface temperature of 350 °C, which presents a particularly challenging environment for the fiber-based subsystem. Along with this temperature design requirement, all the materials in the primary vacuum need to be ultra-high vacuum compatible, able to handle the expected neutron and gamma radiation, as well as tritium exposure, all of which restrict material options. Finally, due to the expected activated environment in SPARC, there will be little chance to replace defective sensors, so system resilience is ensured through toroidal redundancy, probe material selection, and mitigating the impact of common-mode failures. Initial testing of sensors show that intershot structural measurements are sufficiently captured with the raw output, but intrashot measurements of the plasma facing material requires model-based interpretive tools.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Development of a thermal diagnostic system for the SPARC tokamak
The SPARC tokamak will have scrape-off layer parallel heat fluxes on the order of GW/m2. Managing power exhaust of this magnitude will be mandatory for a reactor-scale device. To enable this mission, a thermal diagnostic suite will be deployed to measure the in-vessel structural temperatures to ensure they do not exceed their design limits and to determine the spatial distribution and magnitude of energy deposited onto the first wall. Thermocouples and fiber Bragg gratings have been selected for their environmental compatibility and proven useful on other fusion devices. High-density thermocouple arrays in the divertor will have two spring-loaded thermocouples per divertor target tile, which are being used as calorimeters, and will look to resolve the temperature distribution within the tile due to a swept or static strike point. All systems will need to survive the vacuum vessel bake, set at a minimum plasma facing surface temperature of 350 °C, which presents a particularly challenging environment for the fiber-based subsystem. Along with this temperature design requirement, all the materials in the primary vacuum need to be ultra-high vacuum compatible, able to handle the expected neutron and gamma radiation, as well as tritium exposure, all of which restrict material options. Finally, due to the expected activated environment in SPARC, there will be little chance to replace defective sensors, so system resilience is ensured through toroidal redundancy, probe material selection, and mitigating the impact of common-mode failures. Initial testing of sensors show that intershot structural measurements are sufficiently captured with the raw output, but intrashot measurements of the plasma facing material requires model-based interpretive tools.
- Top Cited PapersOpen Access
- 15 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (11) , 112004
NSTX-U research advancing the physics of spherical tokamaks
The objectives of NSTX-U research are to reinforce the advantages of STs while addressing the challenges. To extend confinement physics of low-A, high beta plasmas to lower collisionality levels, understanding of the transport mechanisms that set confinement performance and pedestal profiles is being advanced through gyrokinetic simulations, reduced model development, and comparison to NSTX experiment, as well as improved simulation of RF heating. To develop stable non-inductive scenarios needed for steady-state operation, various performance-limiting modes of instability were studied, including MHD, tearing modes, and energetic particle instabilities. Predictive tools were developed, covering disruptions, runaway electrons, equilibrium reconstruction, and control tools. To develop power and particle handling techniques to optimize plasma exhaust in high performance scenarios, innovative lithium-based solutions are being developed to handle the very high heat flux levels that the increased heating power and compact geometry of NSTX-U will produce, and will be seen in future STs. Predictive capabilities accounting for plasma phenomena, like edge harmonic oscillations, ELMs, and blobs, are being tested and improved. In these ways, NSTX-U researchers are advancing the physics understanding of ST plasmas to maximize the benefit that will be gained from further NSTX-U experiments and to increase confidence in projections to future devices.
- 15 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (11) , 112004
Top Cited PapersOpen AccessNSTX-U research advancing the physics of spherical tokamaks
The objectives of NSTX-U research are to reinforce the advantages of STs while addressing the challenges. To extend confinement physics of low-A, high beta plasmas to lower collisionality levels, understanding of the transport mechanisms that set confinement performance and pedestal profiles is being advanced through gyrokinetic simulations, reduced model development, and comparison to NSTX experiment, as well as improved simulation of RF heating. To develop stable non-inductive scenarios needed for steady-state operation, various performance-limiting modes of instability were studied, including MHD, tearing modes, and energetic particle instabilities. Predictive tools were developed, covering disruptions, runaway electrons, equilibrium reconstruction, and control tools. To develop power and particle handling techniques to optimize plasma exhaust in high performance scenarios, innovative lithium-based solutions are being developed to handle the very high heat flux levels that the increased heating power and compact geometry of NSTX-U will produce, and will be seen in future STs. Predictive capabilities accounting for plasma phenomena, like edge harmonic oscillations, ELMs, and blobs, are being tested and improved. In these ways, NSTX-U researchers are advancing the physics understanding of ST plasmas to maximize the benefit that will be gained from further NSTX-U experiments and to increase confidence in projections to future devices.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of a bolometry diagnostic for SPARC
To control and optimize the power of the SPARC tokamak, we require information on the total radiated power of the plasma and its 2D and 3D spatial distribution. The SPARC bolometry diagnostic is being designed and built to measure the radiated power for controlling power balance, investigating the dissipation capabilities of various divertor concepts, and measuring the efficacy of the disruption thermal load mitigation. Proven resistive bolometer sensor technology will be used, with 248 lines of sight integrated into pinhole cameras in 20 different locations. This diversity of views will allow the bolometers to view the core, divertor, and particularly X-points of the plasma with high resolution. 14 of these camera locations are dedicated to 2D equilibrium radiated power, while the remaining six locations are designed to measure 3D radiated energy during disruptions. The bolometer sensor holders, pinhole camera boxes, and cabling have been designed to survive the high neutron flux (but low fluence) and up to 400 °C temperatures seen during operation and vacuum bake. The resistive bolometer sensors use Au absorbers with an Al heat conduction layer and C anti-reflective layer. These sensor chips are wire-bonded to an AlN circuit board, both of which are held inside a custom AlN and stainless steel bolometer holder. Design and optimization of the pinhole camera lines of sight are performed using Cherab. This work details the current state of the design of the SPARC bolometry diagnostic and its interfaces, as well as ongoing work to validate the design.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of a bolometry diagnostic for SPARC
To control and optimize the power of the SPARC tokamak, we require information on the total radiated power of the plasma and its 2D and 3D spatial distribution. The SPARC bolometry diagnostic is being designed and built to measure the radiated power for controlling power balance, investigating the dissipation capabilities of various divertor concepts, and measuring the efficacy of the disruption thermal load mitigation. Proven resistive bolometer sensor technology will be used, with 248 lines of sight integrated into pinhole cameras in 20 different locations. This diversity of views will allow the bolometers to view the core, divertor, and particularly X-points of the plasma with high resolution. 14 of these camera locations are dedicated to 2D equilibrium radiated power, while the remaining six locations are designed to measure 3D radiated energy during disruptions. The bolometer sensor holders, pinhole camera boxes, and cabling have been designed to survive the high neutron flux (but low fluence) and up to 400 °C temperatures seen during operation and vacuum bake. The resistive bolometer sensors use Au absorbers with an Al heat conduction layer and C anti-reflective layer. These sensor chips are wire-bonded to an AlN circuit board, both of which are held inside a custom AlN and stainless steel bolometer holder. Design and optimization of the pinhole camera lines of sight are performed using Cherab. This work details the current state of the design of the SPARC bolometry diagnostic and its interfaces, as well as ongoing work to validate the design.