David S. Burch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
David S. Burch has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alireza Abdollahifar
Department of Physiology & Biophysics, Center for Aerospace Physiology, School of Medicine, Case Western Reserve University, Cleveland, OH 44106, USA
1 shared publication - Elizabeth G. Damato
Frances Payne Bolton School of Nursing, Case Western Reserve University, Cleveland, OH 44106-4904, USA
1 shared publication - Joseph S. Piktel
MetroHealth Center Campus of Case Western Reserve University, Department of Emergency Medicine, Cleveland, OH, USA
1 shared publication - Kingman P. Strohl
Department of Physiology & Biophysics, Center for Aerospace Physiology, School of Medicine, Case Western Reserve University, Cleveland, OH 44106, USA
1 shared publication - Lily K. Norton
Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, NY 14203, USA
1 shared publication - Michael John Decker
Byrdine F. Lewis School of Nursing, Georgia State University Atlanta, GA, USA
1 shared publication
Latest Publications
- Open Access
- 14 March 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (6) , 3279
Exposure to Non-Steady-State Oxygen Is Reflected in Changes to Arterial Blood Gas Values, Prefrontal Cortical Activity, and Systemic Cytokine Levels
Onboard oxygen-generating systems (OBOGSs) provide increased inspired oxygen (FiO2) to mitigate the risk of neurologic injury in high altitude aviators. OBOGSs can deliver highly variable oxygen concentrations oscillating around a predetermined FiO2 set point, even when the aircraft cabin altitude is relatively stable. Steady-state exposure to 100% FiO2 evokes neurovascular vasoconstriction, diminished cerebral perfusion, and altered electroencephalographic activity. Whether non-steady-state FiO2 exposure leads to similar outcomes is unknown. This study characterized the physiologic responses to steady-state and non-steady-state FiO2 during normobaric and hypobaric environmental pressures emulating cockpit pressures within tactical aircraft. The participants received an indwelling radial arterial catheter while exposed to steady-state or non-steady-state FiO2 levels oscillating ± 15% of prescribed set points in a hypobaric chamber. Steady-state exposure to 21% FiO2 during normobaria produced arterial blood gas values within the anticipated ranges. Exposure to non-steady-state FiO2 led to PaO2 levels higher upon cessation of non-steady-state FiO2 than when measured during steady-state exposure. This pattern was consistent across all FiO2 ranges, at each barometric condition. Prefrontal cortical activation during cognitive testing was lower following exposure to non-steady-state FiO2 >50% and 50% reduced prefrontal cortical brain activation during the cognitive challenge, consistent with an evoked pattern of neurovascular constriction and dilation.
- 14 March 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (6) , 3279
Open AccessExposure to Non-Steady-State Oxygen Is Reflected in Changes to Arterial Blood Gas Values, Prefrontal Cortical Activity, and Systemic Cytokine Levels
Onboard oxygen-generating systems (OBOGSs) provide increased inspired oxygen (FiO2) to mitigate the risk of neurologic injury in high altitude aviators. OBOGSs can deliver highly variable oxygen concentrations oscillating around a predetermined FiO2 set point, even when the aircraft cabin altitude is relatively stable. Steady-state exposure to 100% FiO2 evokes neurovascular vasoconstriction, diminished cerebral perfusion, and altered electroencephalographic activity. Whether non-steady-state FiO2 exposure leads to similar outcomes is unknown. This study characterized the physiologic responses to steady-state and non-steady-state FiO2 during normobaric and hypobaric environmental pressures emulating cockpit pressures within tactical aircraft. The participants received an indwelling radial arterial catheter while exposed to steady-state or non-steady-state FiO2 levels oscillating ± 15% of prescribed set points in a hypobaric chamber. Steady-state exposure to 21% FiO2 during normobaria produced arterial blood gas values within the anticipated ranges. Exposure to non-steady-state FiO2 led to PaO2 levels higher upon cessation of non-steady-state FiO2 than when measured during steady-state exposure. This pattern was consistent across all FiO2 ranges, at each barometric condition. Prefrontal cortical activation during cognitive testing was lower following exposure to non-steady-state FiO2 >50% and 50% reduced prefrontal cortical brain activation during the cognitive challenge, consistent with an evoked pattern of neurovascular constriction and dilation.