Yue Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yue Ma has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Dan Tong
Department of Radiology, The First Hospital of Jilin University, Changchun, China
2 shared publications - Bitao Zhong
China National Center for Bioinformation , Beijing 100101
1 shared publication - Chunmei Cui
School of Sports Medicine, Wuhan Sports University, Wuhan, China
1 shared publication - Dandan Guo
From the Department of Radiology (M.W., Y.M., L.L., X.P., Y.W., Y.Q., D.G., D.T.), The First Hospital of Jilin University, Changchun, China
1 shared publication - Fan Yang
Guangdong Provincial Key Laboratory of Brain Connectome and Behavior, Shenzhen-Hong Kong Institute of Brain Science, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
1 shared publication - Jianxiu Lian
Philips Healthcare, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 20 August 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (4)
MedImg: An Integrated Database for Public Medical Images
The advancements in deep learning algorithms for medical image analysis have garnered significant attention in recent years. While several studies have shown promising results, with models achieving or even surpassing human performance, translating these advancements into clinical practice is still accompanied by various challenges. A primary obstacle lies in the availability of large-scale, well-characterized datasets for validating the generalization of approaches. To address this challenge, we curated a diverse collection of medical image datasets from multiple public sources, containing 105 datasets and a total of 1,995,671 images. These images span 14 modalities, including X-ray, computed tomography, magnetic resonance imaging, optical coherence tomography, ultrasound, and endoscopy, and originate from 13 organs, such as the lung, brain, eye, and heart. Subsequently, we constructed an online database, MedImg, which incorporates and systematically organizes these medical images to facilitate data accessibility. MedImg serves as an intuitive and open-access platform for facilitating research in deep learning-based medical image analysis, accessible at https://www.cuilab.cn/medimg/.
- 20 August 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (4)
Open AccessMedImg: An Integrated Database for Public Medical Images
The advancements in deep learning algorithms for medical image analysis have garnered significant attention in recent years. While several studies have shown promising results, with models achieving or even surpassing human performance, translating these advancements into clinical practice is still accompanied by various challenges. A primary obstacle lies in the availability of large-scale, well-characterized datasets for validating the generalization of approaches. To address this challenge, we curated a diverse collection of medical image datasets from multiple public sources, containing 105 datasets and a total of 1,995,671 images. These images span 14 modalities, including X-ray, computed tomography, magnetic resonance imaging, optical coherence tomography, ultrasound, and endoscopy, and originate from 13 organs, such as the lung, brain, eye, and heart. Subsequently, we constructed an online database, MedImg, which incorporates and systematically organizes these medical images to facilitate data accessibility. MedImg serves as an intuitive and open-access platform for facilitating research in deep learning-based medical image analysis, accessible at https://www.cuilab.cn/medimg/.
- Open Access
- 14 March 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (4) , 444-452
Compressed Sensitivity Encoding Artificial Intelligence Accelerates Brain Metastasis Imaging by Optimizing Image Quality and Reducing Scan Time
BACKGROUND AND PURPOSE: Accelerating the image acquisition speed of MR imaging without compromising the image quality is challenging. This study aimed to evaluate the feasibility of contrast-enhanced (CE) 3D T1WI and CE 3D-FLAIR sequences reconstructed with compressed sensitivity encoding artificial intelligence (CS-AI) for detecting brain metastases (BM) and explore the optimal acceleration factor (AF) for clinical BM imaging. MATERIALS AND METHODS: Fifty-one patients with cancer with suspected BM were included. Fifty participants underwent different customized CE 3D-T1WI or CE 3D-FLAIR sequence scans. Compressed SENSE encoding acceleration 6 (CS6), a commercially available standard sequence, was used as the reference standard. Quantitative and qualitative methods were used to evaluate image quality. The SNR and contrast-to-noise ratio (CNR) were calculated, and qualitative evaluations were independently conducted by 2 neuroradiologists. After exploring the optimal AF, sample images were obtained from 1 patient by using both optimized sequences. RESULTS: Quantitatively, the CNR of the CS-AI protocol for CE 3D-T1WI and CE 3D-FLAIR sequences was superior to that of the CS protocol under the same AF (P < .05). Compared with reference CS6, the CS-AI groups had higher CNR values (all P < .05), with the CS-AI10 scan having the highest value. The SNR of the CS-AI group was better than that of the reference for both CE 3D-T1WI and CE 3D-FLAIR sequences (all P < .05). Qualitatively, the CS-AI protocol produced higher image quality scores than did the CS protocol with the same AF (all P < .05). In contrast to the reference CS6, the CS-AI group showed good image quality scores until an AF of up to 10 (all P < .05). The CS-AI10 scan provided the optimal images, improving the delineation of normal gray-white matter boundaries and lesion areas (P < .05). Compared with the reference, CS-AI10 showed reductions in scan time of 39.25% and 39.93% for CE 3D-T1WI and CE 3D-FLAIR sequences, respectively. CONCLUSIONS: CE 3D-T1WI and CE 3D-FLAIR sequences reconstructed with CS-AI for the detection of BM may provide a more effective alternative reconstruction approach than CS. CS-AI10 is suitable for clinical applications, providing optimal image quality and a shortened scan time.
- 14 March 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (4) , 444-452
Open AccessCompressed Sensitivity Encoding Artificial Intelligence Accelerates Brain Metastasis Imaging by Optimizing Image Quality and Reducing Scan Time
BACKGROUND AND PURPOSE: Accelerating the image acquisition speed of MR imaging without compromising the image quality is challenging. This study aimed to evaluate the feasibility of contrast-enhanced (CE) 3D T1WI and CE 3D-FLAIR sequences reconstructed with compressed sensitivity encoding artificial intelligence (CS-AI) for detecting brain metastases (BM) and explore the optimal acceleration factor (AF) for clinical BM imaging. MATERIALS AND METHODS: Fifty-one patients with cancer with suspected BM were included. Fifty participants underwent different customized CE 3D-T1WI or CE 3D-FLAIR sequence scans. Compressed SENSE encoding acceleration 6 (CS6), a commercially available standard sequence, was used as the reference standard. Quantitative and qualitative methods were used to evaluate image quality. The SNR and contrast-to-noise ratio (CNR) were calculated, and qualitative evaluations were independently conducted by 2 neuroradiologists. After exploring the optimal AF, sample images were obtained from 1 patient by using both optimized sequences. RESULTS: Quantitatively, the CNR of the CS-AI protocol for CE 3D-T1WI and CE 3D-FLAIR sequences was superior to that of the CS protocol under the same AF (P < .05). Compared with reference CS6, the CS-AI groups had higher CNR values (all P < .05), with the CS-AI10 scan having the highest value. The SNR of the CS-AI group was better than that of the reference for both CE 3D-T1WI and CE 3D-FLAIR sequences (all P < .05). Qualitatively, the CS-AI protocol produced higher image quality scores than did the CS protocol with the same AF (all P < .05). In contrast to the reference CS6, the CS-AI group showed good image quality scores until an AF of up to 10 (all P < .05). The CS-AI10 scan provided the optimal images, improving the delineation of normal gray-white matter boundaries and lesion areas (P < .05). Compared with the reference, CS-AI10 showed reductions in scan time of 39.25% and 39.93% for CE 3D-T1WI and CE 3D-FLAIR sequences, respectively. CONCLUSIONS: CE 3D-T1WI and CE 3D-FLAIR sequences reconstructed with CS-AI for the detection of BM may provide a more effective alternative reconstruction approach than CS. CS-AI10 is suitable for clinical applications, providing optimal image quality and a shortened scan time.
- Open Access
- 13 October 2018
- Published by Association for Computing Machinery (ACM)
- p. 138-142
Application of Image Segmentation on Evaluating Infarct Core in Acute Ischemic Stroke Using CT Perfusion
- 13 October 2018
- Published by Association for Computing Machinery (ACM)
- p. 138-142
Open AccessApplication of Image Segmentation on Evaluating Infarct Core in Acute Ischemic Stroke Using CT Perfusion