Shengwen Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shengwen Guo has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Congling Wu
Department of Biomedical Engineering, School of Material Science and Engineering, South China University of Technology, Guangzhou, China
4 shared publicationsChunren Lai
Department of Biomedical Engineering, South China University of Technology, Guangzhou, China
3 shared publicationsBenheng Xiao
Department of Biomedical Engineering, School of Material Science and Engineering, South China University of Technology, Guangzhou, China
2 shared publicationsGuiyin Cen
Guangdong General Hospital Guangzhou, China
2 shared publicationsLang Zhou
Department of Biomedical Engineering School of Material Science and Engineering South China University of Technology Guangzhou Guangdong China
2 shared publicationsQin Zhang
Department of Biomedical Engineering School of Material Science and Engineering South China University of Technology Guangzhou Guangdong China
2 shared publications
Latest Publications
- 25 December 2025
- Vol. 42 (6) , 1172-1180
[Adaptive lesion-aware fusion network for joint grading of multiple fundus diseases].
Diabetic retinopathy (DR) and its complication, diabetic macular edema (DME), are major causes of visual impairment and even blindness. The occurrence of DR and DME is pathologically interconnected, and their clinical diagnoses are closely related. Joint learning can help improve the accuracy of diagnosis. This paper proposed a novel adaptive lesion-aware fusion network (ALFNet) to facilitate the joint grading of DR and DME. ALFNet employed DenseNet-121 as the backbone and incorporated an adaptive lesion attention module (ALAM) to capture the distinct lesion characteristics of DR and DME. A deep feature fusion module (DFFM) with a shared-parameter local attention mechanism was designed to learn the correlation between the two diseases. Furthermore, a four-branch composite loss function was introduced to enhance the network's multi-task learning capability. Experimental results demonstrated that ALFNet achieved superior joint grading performance on the Messidor dataset, with joint accuracy rates of 0.868 (DR 2 & DME 3), outperforming state-of-the-art methods. These results highlight the unique advantages of the proposed approach in the joint grading of DR and DME, thereby improving the efficiency and accuracy of clinical decision-making.
- 25 December 2025
- Vol. 42 (6) , 1172-1180
[Adaptive lesion-aware fusion network for joint grading of multiple fundus diseases].
Diabetic retinopathy (DR) and its complication, diabetic macular edema (DME), are major causes of visual impairment and even blindness. The occurrence of DR and DME is pathologically interconnected, and their clinical diagnoses are closely related. Joint learning can help improve the accuracy of diagnosis. This paper proposed a novel adaptive lesion-aware fusion network (ALFNet) to facilitate the joint grading of DR and DME. ALFNet employed DenseNet-121 as the backbone and incorporated an adaptive lesion attention module (ALAM) to capture the distinct lesion characteristics of DR and DME. A deep feature fusion module (DFFM) with a shared-parameter local attention mechanism was designed to learn the correlation between the two diseases. Furthermore, a four-branch composite loss function was introduced to enhance the network's multi-task learning capability. Experimental results demonstrated that ALFNet achieved superior joint grading performance on the Messidor dataset, with joint accuracy rates of 0.868 (DR 2 & DME 3), outperforming state-of-the-art methods. These results highlight the unique advantages of the proposed approach in the joint grading of DR and DME, thereby improving the efficiency and accuracy of clinical decision-making.
- Open Access
- 14 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 279-284
Anxiety Status Assessment Method Based on a Portable EEG Signal Detection and Virtual Reality Integration System
- 14 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 279-284
Open AccessAnxiety Status Assessment Method Based on a Portable EEG Signal Detection and Virtual Reality Integration System
- Open Access
- 29 September 2025
- Published by Wiley in Medical Physics
- Vol. 52 (10) , e70038
Developing machine learning‐driven acute kidney injury predictive models using non‐standard EMRs in resource‐limited settings
Background: Acute Kidney Injury (AKI) remains a significant global health challenge, especially in resource‐limited settings. Most existing predictive models rely heavily on serum creatinine (SCr) levels and standardized electronic medical records (EMRs). However, in many low‐resource environments, SCr testing is infrequent, and EMR systems often lack standardization in data structure, terminology, and recording practices (a.k.a., non‐standard EMRs). These limitations hinder the consistent extraction of features needed for accurate AKI prediction and highlight the urgent need for adaptive frameworks tailored to diverse and resource‐limited healthcare environments. Purpose: This study aimed to develop and validate a machine learning model using non‐standardized EMRs for predicting AKI, even without SCr data. Methods: This multicenter observational study, conducted from 2010 to 2016 across 15 hospitals in China, employed the Light Gradient Boosting Machine (LightGBM) to create predictive models. The model's performance was assessed using area under the curve (AUC), precision, recall, specificity, and accuracy. Results: A total of 561 137 hospitalized patients were eligible for the analyses, of whom 45 610 were diagnosed with AKI. The LightGBM model demonstrated high accuracy in predicting AKI, with AUC values ranging from 0.860 to 0.986. The study showed that non‐standard EMRs could effectively predict AKI. Importantly, the model maintained strong predictive performance even without SCr data, indicating that AKI can be accurately predicted without this traditional biomarker. Conclusion: Non‐standard EMRs are valuable for predicting AKI, even in the absence of SCr data. This approach is particularly useful in resource‐limited settings, where traditional biomarkers are often unavailable, demonstrating the potential of other clinical features to compensate for missing SCr data in AKI prediction.
- 29 September 2025
- Published by Wiley in Medical Physics
- Vol. 52 (10) , e70038
Open AccessDeveloping machine learning‐driven acute kidney injury predictive models using non‐standard EMRs in resource‐limited settings
Background: Acute Kidney Injury (AKI) remains a significant global health challenge, especially in resource‐limited settings. Most existing predictive models rely heavily on serum creatinine (SCr) levels and standardized electronic medical records (EMRs). However, in many low‐resource environments, SCr testing is infrequent, and EMR systems often lack standardization in data structure, terminology, and recording practices (a.k.a., non‐standard EMRs). These limitations hinder the consistent extraction of features needed for accurate AKI prediction and highlight the urgent need for adaptive frameworks tailored to diverse and resource‐limited healthcare environments. Purpose: This study aimed to develop and validate a machine learning model using non‐standardized EMRs for predicting AKI, even without SCr data. Methods: This multicenter observational study, conducted from 2010 to 2016 across 15 hospitals in China, employed the Light Gradient Boosting Machine (LightGBM) to create predictive models. The model's performance was assessed using area under the curve (AUC), precision, recall, specificity, and accuracy. Results: A total of 561 137 hospitalized patients were eligible for the analyses, of whom 45 610 were diagnosed with AKI. The LightGBM model demonstrated high accuracy in predicting AKI, with AUC values ranging from 0.860 to 0.986. The study showed that non‐standard EMRs could effectively predict AKI. Importantly, the model maintained strong predictive performance even without SCr data, indicating that AKI can be accurately predicted without this traditional biomarker. Conclusion: Non‐standard EMRs are valuable for predicting AKI, even in the absence of SCr data. This approach is particularly useful in resource‐limited settings, where traditional biomarkers are often unavailable, demonstrating the potential of other clinical features to compensate for missing SCr data in AKI prediction.
- 12 March 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 93
Multi-task parallel with feature sharing integrated 3D U-Nets for Glioma Segmentation
- 12 March 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 93
Multi-task parallel with feature sharing integrated 3D U-Nets for Glioma Segmentation
- Open Access
A low-cost, wireless, 4-channel EEG measurement system used in virtual reality environments
- 25 April 2023
- Vol. 40 (2) , 202-207
基于关键点的超声图像与磁共振图像多分辨率离散优化配准方法
脑肿瘤手术规划及术中,术前磁共振(MR)图像与术中超声(US)图像的配准甚为关键。考虑到两种模态图像具有不同密度范围及分辨率,且超声图像存在较多的斑点噪声干扰,采用一种基于局部邻域信息的自相似性上下文(SSC)描述子定义图像之间的相似性测度。将超声图像作为参考,使用三维微分运算提取其中角点作为关键点,并采用密集位移采样离散优化算法实施配准。整个配准过程分为仿射配准和弹性配准两个阶段,在仿射配准阶段,对图像进行多分辨率分解,在弹性配准阶段,采取最小卷积和均值场推理策略对关键点的位移向量进行正则化处理。对22名患者的术前MR和术中US图像进行配准实验,仿射配准后的误差为(1.57 ± 0.30)mm,每对图像配准平均耗时1.36 s;弹性配准后的误差为(1.40 ± 0.28)mm,平均用时1.53 s。实验结果证明本文采用的方法具有良好的配准精度和速度。
- 25 April 2023
- Vol. 40 (2) , 202-207
基于关键点的超声图像与磁共振图像多分辨率离散优化配准方法
脑肿瘤手术规划及术中,术前磁共振(MR)图像与术中超声(US)图像的配准甚为关键。考虑到两种模态图像具有不同密度范围及分辨率,且超声图像存在较多的斑点噪声干扰,采用一种基于局部邻域信息的自相似性上下文(SSC)描述子定义图像之间的相似性测度。将超声图像作为参考,使用三维微分运算提取其中角点作为关键点,并采用密集位移采样离散优化算法实施配准。整个配准过程分为仿射配准和弹性配准两个阶段,在仿射配准阶段,对图像进行多分辨率分解,在弹性配准阶段,采取最小卷积和均值场推理策略对关键点的位移向量进行正则化处理。对22名患者的术前MR和术中US图像进行配准实验,仿射配准后的误差为(1.57 ± 0.30)mm,每对图像配准平均耗时1.36 s;弹性配准后的误差为(1.40 ± 0.28)mm,平均用时1.53 s。实验结果证明本文采用的方法具有良好的配准精度和速度。
- 1 January 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 140, 105097
Prediction of acute kidney injury in ICU with gradient boosting decision tree algorithms
- 1 January 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 140, 105097
Prediction of acute kidney injury in ICU with gradient boosting decision tree algorithms
- Open Access
- 1 July 2020
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 10 (7) , 1477-1489
Identifying subtypes of mild cognitive impairment from healthy aging based on multiple cortical features combined with volumetric measurements of the hippocampal subfields
Background: Mild cognitive impairment (MCI) is subtle cognitive decline with an estimated 10–15% yearly conversion rate toward Alzheimer’s disease (AD). It remains unexplored in brain cortical association areas in different lobes and its changes with progression and conversion of MCI. Methods: Brain structural magnetic resonance (MR) images were collected from 102 stable MCI (sMCI) patients. One hundred eleven were converted MCI (cMCI) patients, and 109 were normal control (NC). The cortical surface features and volumes of subcortical hippocampal subfields were calculated using the FreeSurfer software, followed by an analysis of variance (ANOVA) model, to reveal the differences between the NC-sMCI, NC-cMCI, and sMCI-cMCI groups. Afterward, the support vector machine-recursive feature elimination (SVM-RFE) method was applied to determine the differences between the groups. Results: The experimental results showed that there were progressive degradations in either range or degree of the brain structure from NC to sMCI, and then to cMCI. The SVM classifier obtained accuracies with 64.62%, 78.96%, and 70.33% in the sMCI-NC, cMCI-NC, and cMCI-sMCI groups, respectively, using the volumes of hippocampal subfields independently. The combination of the volumes from the hippocampal subfields and cortical measurements could significantly increase the performance to 71.86%, 84.64%, and 76.86% for the sMCI-NC, cMCI-NC, and cMCI-sMCI classifications, respectively. Also, the brain regions corresponding to the dominant features with strong discriminative power were widely located in the temporal, frontal, parietal, olfactory cortexes, and most of the hippocampal subfields, which were associated with cognitive decline, memory impairment, spatial navigation, and attention control. Conclusions: The combination of cortical features with the volumes of hippocampal subfields could supply critical information for MCI detection and its conversion.
- 1 July 2020
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 10 (7) , 1477-1489
Open AccessIdentifying subtypes of mild cognitive impairment from healthy aging based on multiple cortical features combined with volumetric measurements of the hippocampal subfields
Background: Mild cognitive impairment (MCI) is subtle cognitive decline with an estimated 10–15% yearly conversion rate toward Alzheimer’s disease (AD). It remains unexplored in brain cortical association areas in different lobes and its changes with progression and conversion of MCI. Methods: Brain structural magnetic resonance (MR) images were collected from 102 stable MCI (sMCI) patients. One hundred eleven were converted MCI (cMCI) patients, and 109 were normal control (NC). The cortical surface features and volumes of subcortical hippocampal subfields were calculated using the FreeSurfer software, followed by an analysis of variance (ANOVA) model, to reveal the differences between the NC-sMCI, NC-cMCI, and sMCI-cMCI groups. Afterward, the support vector machine-recursive feature elimination (SVM-RFE) method was applied to determine the differences between the groups. Results: The experimental results showed that there were progressive degradations in either range or degree of the brain structure from NC to sMCI, and then to cMCI. The SVM classifier obtained accuracies with 64.62%, 78.96%, and 70.33% in the sMCI-NC, cMCI-NC, and cMCI-sMCI groups, respectively, using the volumes of hippocampal subfields independently. The combination of the volumes from the hippocampal subfields and cortical measurements could significantly increase the performance to 71.86%, 84.64%, and 76.86% for the sMCI-NC, cMCI-NC, and cMCI-sMCI classifications, respectively. Also, the brain regions corresponding to the dominant features with strong discriminative power were widely located in the temporal, frontal, parietal, olfactory cortexes, and most of the hippocampal subfields, which were associated with cognitive decline, memory impairment, spatial navigation, and attention control. Conclusions: The combination of cortical features with the volumes of hippocampal subfields could supply critical information for MCI detection and its conversion.
- Open Access
Validation study of a diffusion MRI derived vessel density biomarker for detecting viral hepatitis-b induced liver fibrosis
Aim: Liver vessel density can be evaluated by an imaging biomarker DDVD (diffusion derived vessel density): DDVD/area(b0b2) = Sb0/ROIarea0 – Sb2/ROIarea2, where Sb0 and Sb2 refer to the liver signal when b is 0 or 2 (s/mm 2 ); ROIarea0 and ROIarea2 refer to the region-of-interest on b = 0 or 2 images; and Sb2 may be replaced by Sb15 ( b =15). This concept was validated in this study. Materials and Methods: Liver diffusion images were acquired at 1.5T. For a scan-rescan repeatability study of 6 subjects, b -values of 0 and 2 were used. The validation study composed of 26 healthy volunteers and 19 consecutive suspected chronic viral hepatitis-b patients, and diffusion images with 16 b -values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, 600 were acquired. Four patients did not have liver fibrosis, and the rest were four stage-1, three stage-2, four stage 3, and one stage-4 patients respectively. Results: Intraclass correlation coefficient for repeatability was 0.994 for DDVD/area(Sb0Sb2), and 0.978 for DDVD/area(Sb0Sb15). In the validation study, DDVD/area(Sb0Sb2) and area(Sb0Sb15) were 14.80±3.06 and 26.58±3.97 for healthy volunteers, 10.51±1.51 and 20.15±2.21 for stage 1-2 fibrosis patients, and 9.42±0.87 and 19.42±1.89 for stage 3-4 fibrosis patients. For 16 patients where IVIM analysis was performed, a combination of DDVD/area, PF, and Dfast achieved the best differentiation for non-fibrotic livers and fibrotic livers. DDVD/area were weakly correlated with PF or Dfast. Conclusion: Both DDVD/area(Sb0Sb2) and area(Sb0Sb15) are useful imaging biomarker to separate fibrotic and non-fibrotic livers, with fibrotic livers had lower measurements.
Open AccessValidation study of a diffusion MRI derived vessel density biomarker for detecting viral hepatitis-b induced liver fibrosis
Aim: Liver vessel density can be evaluated by an imaging biomarker DDVD (diffusion derived vessel density): DDVD/area(b0b2) = Sb0/ROIarea0 – Sb2/ROIarea2, where Sb0 and Sb2 refer to the liver signal when b is 0 or 2 (s/mm 2 ); ROIarea0 and ROIarea2 refer to the region-of-interest on b = 0 or 2 images; and Sb2 may be replaced by Sb15 ( b =15). This concept was validated in this study. Materials and Methods: Liver diffusion images were acquired at 1.5T. For a scan-rescan repeatability study of 6 subjects, b -values of 0 and 2 were used. The validation study composed of 26 healthy volunteers and 19 consecutive suspected chronic viral hepatitis-b patients, and diffusion images with 16 b -values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, 600 were acquired. Four patients did not have liver fibrosis, and the rest were four stage-1, three stage-2, four stage 3, and one stage-4 patients respectively. Results: Intraclass correlation coefficient for repeatability was 0.994 for DDVD/area(Sb0Sb2), and 0.978 for DDVD/area(Sb0Sb15). In the validation study, DDVD/area(Sb0Sb2) and area(Sb0Sb15) were 14.80±3.06 and 26.58±3.97 for healthy volunteers, 10.51±1.51 and 20.15±2.21 for stage 1-2 fibrosis patients, and 9.42±0.87 and 19.42±1.89 for stage 3-4 fibrosis patients. For 16 patients where IVIM analysis was performed, a combination of DDVD/area, PF, and Dfast achieved the best differentiation for non-fibrotic livers and fibrotic livers. DDVD/area were weakly correlated with PF or Dfast. Conclusion: Both DDVD/area(Sb0Sb2) and area(Sb0Sb15) are useful imaging biomarker to separate fibrotic and non-fibrotic livers, with fibrotic livers had lower measurements.