Francisco Cuenca-Jiménez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francisco Cuenca-Jiménez has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Velázquez-Villegas
Engineering Design Department, School of Engineering, UNAM, Coyoacán, México
1 shared publication - J. Guadalupe Velásquez Aguilar
Facultad de Ciencias Químicas e Ingeniería, Universidad Autónoma del Estado de Morelos, Avenida Universidad 1001, Colonia Chamilpa, Cuernavaca 62209, Mexico
1 shared publication - Mario Acosta-Flores
Facultad de Ciencias Químicas e Ingeniería (FCQeI), Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Cuernavaca 62209, Morelos, Mexico
1 shared publication - Marta Lilia Eraña-Díaz
Cognitive Sciences Research Center, Autonomous University of the State of Morelos (UAEM), Av. Universidad 1001, Col. Chamilpa, Cuernavaca 62209, Morelos, Mexico
1 shared publication - Martha Roselia Contreras-Valenzuela
Universidad Autónoma del Estado de Morelos
1 shared publication - Shair Mendoza-Flores
Engineering Design Department, School of Engineering, UNAM, Coyoacán, México
1 shared publication
Latest Publications
- Open Access
- 8 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 3981
Triaxial Load Cell for Ergonomic Risk Assessment: A Study Case of Applied Force of Thumb
To assess the ergonomic risk level in work systems involving tasks performed with hands or fingers, it is necessary to know the exerted triaxial forces. To address this need, a prototype of a triaxial load cell based on principles of linear elasticity theory and mechanical problems of torsion, bending and axial load is presented. This work includes an analytical strain model for each instrumented point and its solution regarding the applied force to a triaxial load cell. The proposed load cell was calibrated and validated by performing different static experimental tests. As a case study, the applied force in three directions while the thumb activates a cigarette lighter was measured. Triaxial forces and resultant forces were obtained and compared with the parameter of 10 N established by the ergonomic standards as reference values for pressing down with the thumb, finding that the applied forces in eight tests were 23.73 N, 43.51 N, 12.69 N, 14.50 N 20.35 N, 21.67 N, 39.74 N and 46.02 N, exceeding the reference values and establishing a direct relationship with Quervain syndrome. In conclusion, the developed load cell is a valid and reliable alternative to measure many forces that cannot be obtained with commercial devices, allowing the level of ergonomic risk to be determined with great precision.
- 8 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 3981
Open AccessTriaxial Load Cell for Ergonomic Risk Assessment: A Study Case of Applied Force of Thumb
To assess the ergonomic risk level in work systems involving tasks performed with hands or fingers, it is necessary to know the exerted triaxial forces. To address this need, a prototype of a triaxial load cell based on principles of linear elasticity theory and mechanical problems of torsion, bending and axial load is presented. This work includes an analytical strain model for each instrumented point and its solution regarding the applied force to a triaxial load cell. The proposed load cell was calibrated and validated by performing different static experimental tests. As a case study, the applied force in three directions while the thumb activates a cigarette lighter was measured. Triaxial forces and resultant forces were obtained and compared with the parameter of 10 N established by the ergonomic standards as reference values for pressing down with the thumb, finding that the applied forces in eight tests were 23.73 N, 43.51 N, 12.69 N, 14.50 N 20.35 N, 21.67 N, 39.74 N and 46.02 N, exceeding the reference values and establishing a direct relationship with Quervain syndrome. In conclusion, the developed load cell is a valid and reliable alternative to measure many forces that cannot be obtained with commercial devices, allowing the level of ergonomic risk to be determined with great precision.
- Open Access
- 13 March 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (4) , 6865-6884
Optimization of a Horizontal Washing Machine Suspension System: Studying a 7 DOF Dynamic Model Using a Genetic Algorithm Through a Bounding Box Fitness Function
Purpose: This study addresses the optimization process of a horizontal washing machine suspension modeled after a dynamic 7 DOF model. Methodology: A dynamical model of a horizontal washing machine is built. A simple genetic algorithm is applied to determine the optimal parameters for damping, stiffness, and position of the suspension elements by minimizing the weighted fitness function. The fitness function uses the bounding box to enclose the kinematic data of the washing machine mass center and minimize them. Finally, the Bode diagrams were used to evaluate the general aspect of the genetic algorithm performance. Results and Conclusions: The results show remarkable improvements in the displacement, velocity, and acceleration of the center of mass of the washing machine, drastically reducing vibrations and reducing the time needed to reach the final spin speed.
- 13 March 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (4) , 6865-6884
Open AccessOptimization of a Horizontal Washing Machine Suspension System: Studying a 7 DOF Dynamic Model Using a Genetic Algorithm Through a Bounding Box Fitness Function
Purpose: This study addresses the optimization process of a horizontal washing machine suspension modeled after a dynamic 7 DOF model. Methodology: A dynamical model of a horizontal washing machine is built. A simple genetic algorithm is applied to determine the optimal parameters for damping, stiffness, and position of the suspension elements by minimizing the weighted fitness function. The fitness function uses the bounding box to enclose the kinematic data of the washing machine mass center and minimize them. Finally, the Bode diagrams were used to evaluate the general aspect of the genetic algorithm performance. Results and Conclusions: The results show remarkable improvements in the displacement, velocity, and acceleration of the center of mass of the washing machine, drastically reducing vibrations and reducing the time needed to reach the final spin speed.