PSPuneet Sharma

Puneet Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Puneet Sharma has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Flexible Resistive Strain Sensor based on PDMS Coated MWCNTs and MWCNTs/GNP for Wrist Pulse and Respiration Monitoring

    by Puneet Sharma, Suraj Baloda, Deepak Verma, Vijay Janyani, Ritu Sharma, Navneet Gupta

    This work presents a simple fabrication method for detecting human wrist pulse and respiration rate using a flexible resistive strain sensor. Two types of flexible strain sensors were fabricated, one based on polydimethylsiloxane (PDMS) coated multiwall carbon nanotubes (MWCNTs) and the other MWCNTs / graphene nano platelets (GNP) composite on a PDMS substrate. Both sensors exhibited high sensitivity, with gauge factors of 35.37 for MWCNT-based sensors and 49.53 for MWCNT+GNP-based sensors, and excellent stretchability, with detectable strain ranges of up to 236% and 164%, respectively. By detecting changes in resistance relative to applied mechanical strain, these sensors effectively captured weak wrist signals and breathing rates of 17 breaths per minute for MWCNT-based sensors and 20 breaths per minute for MWCNT+GNP-based sensors. The fabricated sensors demonstrated high performance and applicability, making them suitable for use in wearable health monitoring devices.


  • Spray Coated GNP-PDMS Flexible Patch Antenna-Sensor for Wireless Wearable Applications

    by Anup Kumar Sharma, Ritu Sharma, Puneet Sharma, Mamta Devi Sharma

    This paper presents the synthesis and performance of a novel flexible patch antenna sensor based on graphene nanoplatelets (GNP) material designed to operate at the 5.8 GHz frequency, targeting wearable applications. The fabrication process employed in this chapter involved a simple yet effective spray coating method, utilizing a GNP dispersion applied with a spray gun to form a rectangular patch with a full ground plane on the PDMS substrate. This method offers the advantages of being cost-effective and scalable, making it suitable for large-scale production. The antenna's performance as a sensor was evaluated by subjecting it to different bending scenarios, mimicking both compressive (positive bending) and tensile (negative bending) strains. The resulting shifts in resonant frequency under these conditions offered important information about the sensor's sensitivity. The practical applicability of the antenna sensor was demonstrated through human limb motion detection experiments, specifically tracking wrist movements. The sensor's ability to detect upward and downward wrist motions through variations in the normalized frequency output highlights its potential for real-world wearable applications. In addition to its promising performance, the operation of this antenna within the Industrial/Scientific/Medical (ISM) band at 5.8 GHz opens up a range of potential applications.


  • Open Access

    Development of SWCNTs/PDMS Composite Strain Sensors Integrated Smart Glove for Human-Machine Interface Applications

    by Suraj Baloda, Sashank Krishna Sriram, Puneet Sharma, Sumitra Singh, Navneet Gupta

    Smart gloves with their multifunctional sensing capabilities, hold a promising in human–machine interface (HMI) applications. In this work, we present a smart glove based on single-walled carbon nanotubes (SWCNTs) incorporated within a polydimethylsiloxane (PDMS) matrix integrated flexible strain sensor. The flexible strain sensor is designed and fabricated to serve as a crucial sensing component for the smart glove. The integration of SWCNTs with PDMS offers a unique combination of mechanical flexibility and electrical sensitivity, making it an ideal candidate for real-time monitoring and feedback in HMI applications. The fabricated SWCNTs/PDMS strain exhibits a high sensing range, covering up to a strain range of 70%, along with high sensitivity, characterized by a gauge factor (GF) of 73. Additionally, the strain sensor demonstrates excellent linearity, reliability and durability, enduring repeated loading and unloading for 3000 cycles under a 50% strain. Furthermore, the developed smart glove successfully extends sensing functionality, enabling real time-tasks such as finger motion detection, controlling robotic fingers and can be used in the field of smart wearable electronics and human-machine interface applications. Index Terms-flexible strain sensor, gesture recognition, human-machine interface (HMI), polydimethylsiloxane (PDMS), single-walled carbon nanotubes (SWCNTs), smart gloves, wearable electronics.


  • Multifunctional Transparent Conductive Flexible Sensor Based on Graphene/Polyaniline/ Graphene Sandwich Composite on PDMS Substrate

    by Anup Kumar Sharma, Ritu Sharma, Puneet Sharma, Surbhi Singh

    A novel and simplified method is introduced for synthesizing a transparent sensor based on Graphene-PDMS. The Chemical Vapor deposition (CVD) grown single layer graphene on the PDMS substrate suffers from low conductivity due to defects at the grain boundaries. The fabricated sensor incorporates a polyaniline layer between two graphene layers to maintain enhanced conductivity even when subjected to strain, due to its flexibility. The tri-layer structure of Graphene-Polyaniline-Graphene achieves approximately 90% transmittance and a lower sheet resistance (≈84 Ω/Sq) on a flexible substrate that surpasses those achieved with a single-layer graphene on PDMS and other sandwich structures on a PDMS substrate. The developed transparent and highly conductive Graphene-PANI-Graphene (G-P-G) sensor exhibits effective sensing for finger tapping/touch, strain detection, human motion detection, wrist pulse detection, breathing detection, and traditional NADI detection. This underscores its versatility for various sensing applications. In summary, the demonstrated results indicate the potential of this single transparent conductive sensor structure for deployment in diverse and multifunctional sensing applications.


  • Multiwall Carbon Nanotube/Polydimethylsiloxane Composites-Based Dry Electrodes for Bio-Signal Detection

    by Puneet Sharma, Suraj Baloda, Deepak Verma, Vijay Janyani, Ritu Sharma, Navneet Gupta

    Continuous, stable and long-term monitoring of bio-signals such as electrocardiogram (ECG) and electromyography (EMG) are utmost important in health-care sector. In this work, we developed a MWCNTs/PDMS composites based bio-electrodes using a simple, low-cost and solution-process method. The fabricated MWCNTs/PDMS composites electrode exhibited comparable electrode skin-impedance to conventional Ag/AgCl electrodes over the frequency range 20Hz-1 kHz. In addition, our developed electrodes has the ability to be applied on the skin in dry form without needing an intermediate gel layer or skin preparation. The results shows that the MWCNTs/PDMS based dry electrodes were efficient to acquire a real time ECG signals. The fabricated electrodes showed better performance compared to the commercially available Ag/AgCl electrode in ECG and EMG measurements. The obtained results shows that the proposed dry bio-electrodes has a promising application in electronic/mobile health applications and wearable health monitoring applications.


  • Open Access

    Comparison of Two Novel Techniques for Iris Centering in Ocular Prosthesis

    by Dhananjay Arora, Shefali Singla, Lalit Kumar, Komal Sehgal, Puneet Sharma

    Eyes are among the first features of the face to be noticed. Loss of an eye due to congenital, traumatic, or pathologic etiologies causes disfigurement and loss of sensory feedback. It leaves a psychological impact on the patient; thus, prosthesis should be provided at the earliest to raise the spirits of the afflicted. Iris positioning is one of the important steps in fabricating customized ocular prosthesis. In facial asymmetry cases, comparison of both irises together can be a major disadvantage. This case report illustrates the use of a regular eyeglass in one technique and the use of a bioart facebow in the second technique for centering of iris in a customized ocular prosthesis to overcome the disadvantages of earlier used standard techniques (McArthur’s ocular locator and fixed calliper, pupillometer, visual judgement, and graph grid) of iris centering.


  • Open Access

    Optical coherence tomography-based freeze-drying microscopy

    by Mircea Mujat, Kristyn Greco, Kristin L. Galbally-Kinney, Daniel X. Hammer, R. Daniel Ferguson, Nicusor Iftimia, Phillip Mulhall, Puneet Sharma, Michael J. Pikal, William J. Kessler

    A new type of freeze-drying microscope based upon time-domain optical coherence tomography is presented here (OCT-FDM). The microscope allows for real-time, in situ 3D imaging of pharmaceutical formulations in vials relevant for manufacturing processes with a lateral resolution of <7 μm and an axial resolution of <5 μm. Correlation of volumetric structural imaging with product temperature measured during the freeze-drying cycle allowed investigation of structural changes in the product and determination of the temperature at which the freeze-dried cake collapses. This critical temperature is the most important parameter in designing freeze-drying processes of pharmaceutical products.