SSSong Song

Song Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Song Song has a total of 74 co-authors. Here are the top co-authors by number of shared publications:

  • Xiao Deng

    Tongji University

    6 shared publications
  • Xinbin Cheng

    Tongji University

    4 shared publications
  • Pengfei Niu

    Tianjin University

    3 shared publications
  • Guangxu Xiao

    School of Physics Science and Engineering, Institute of Precision Optical Engineering, the MOE Key Laboratory of Advanced Micro-Structured Materials, Shanghai Frontiers Science Center of Digital Optics, Shanghai Professional Technical Service Platform for Full-Spectrum and High-Performance Optical Thin Film Devices and Applications, and the School of Physics Science and Engineering, Tongji University, Shanghai, China

    2 shared publications
  • Guangxu Xiao

    National Metrology and Testing Center for Integrated Circuit Measurement and Inspection Equipment Industry (Shanghai), Tongji University, Shanghai 200092, China

    2 shared publications
  • Tongbao Li

    School of Physics Science and Engineering, Institute of Precision Optical Engineering, the MOE Key Laboratory of Advanced Micro-Structured Materials, Shanghai Frontiers Science Center of Digital Optics, Shanghai Professional Technical Service Platform for Full-Spectrum and High-Performance Optical Thin Film Devices and Applications, and the School of Physics Science and Engineering, Tongji University, Shanghai, China

    2 shared publications

Latest Publications

  • Open Access

    Evaluation of Periodic Nonlinear Error in a Directly Traceable Grating Interferometer

    by Wenjia Xu, Zichao Lin, Song Song, Chunling He, Yaao Yang, Guangxu Xiao, Xiao Deng

    Periodic nonlinear error (PNE) is a key factor limiting the accuracy of displacement measurement instruments. For grating interferometers, which are widely used in high-precision displacement measurement, reliable characterization of PNE is essential. Conventional evaluation methods that rely on higher-precision instruments become unsuitable for ultra-high-accuracy systems. Although the self-evaluation method based on Lissajous figures are commonly used, their results inherently depend on the grating parameters and the interferometric signals themselves, leading to a lack of traceability and reduced credibility of the results. In this work, we propose a traceable self-evaluation method for assessing the PNE of a directly traceable grating interferometer (DTGI). The DTGI employs a chromium (Cr) atom lithography grating, whose pitch is directly traceable to the atomic transition frequency of Cr (7S3 → 7P4), as its displacement reference, thereby overcoming the traceability deficiencies of conventional self-evaluation methods. Numerical simulations confirm the validity of the proposed method, and experiments performed on a laboratory-built DTGI demonstrate 10-picometer-level PNE after Heydemann correction within micrometer range displacements. These results confirm the method’s suitability for metrological applications requiring stringent linearity performance in nanometric displacement measurement.


  • A Novel On-Site Primary Accelerometer Calibration Method Based on Homodyne Self-Traceable Grating Interferometer

    by Zhikun Chang, Xiao Deng, Haoran Zhang, Xiaoling Han, Xiaoyu Shen, Pengfei Niu, Jing Yu, Song Song, Xinbin Cheng, Zhoumiao Shi, et al.

    As a key component in motion state sensing, the accuracy of accelerometers directly affect the performance and safety of their systems. However, their sensitivity can influenced due to various factors during operation, necessitating both pre-deployment and periodic calibration. Traditional primary calibration methods rely on laser interferometers, yet their trueness and stability are compromised by environmental disturbances affecting the laser wavelength, making on-site traceability challenging. Addressing these issues, this study combines a Cr self-traceable grating with a homodyne littrow grating interferometer and primary vibration calibration technique. Leveraging the high line density, stability, and traceability of the self-traceable grating, it achieves high accuracy and on-site traceable calibration. In experiments, the effectiveness of this calibration system was validated using commercial accelerometers, achieving a measurement uncertainty of 0.25%. This calibration technique not only enhances the accuracy and environmental adaptability of accelerometer calibration but also addresses the critical issue of on-site traceability, representing the future direction of in-field accelerometer calibration.


  • An Ultrahigh-Linearity MOEMS Accelerometer Based on a Self-Traceable Grating Interferometer

    by Zhikun Chang, Song Song, Pengfei Niu, Guangxu Xiao, Zichao Lin, Chunling He, Xiao Deng, Dongbai Xue, Yuying Xie, Xinbin Cheng, et al.

    The linearity of the accelerometer directly affects its measurement accuracy and applicability, making it a key metric in the development of high-performance accelerometers. In response, this paper proposes an ultra-high linearity MOEMS accelerometer based on a self-traceable grating (STG) interferometer. The accelerometer integrates a MEMS resonator with a STG interferometer based on chromium (Cr) atom transition frequency 7S3 → 7P4, enabling direct traceability of displacement to the International System of Units (SI) “meter”. Specifically, the average pitch of the Cr grating used is (212.781±0.008) nm (k = 2), showing outstanding uniformity and long-term stability. Furthermore, the compact interferometer design gives it an overall size of just 7.5 cm × 7.5 cm × 2 cm, facilitating portable measurements in practical applications. Experimental results show that the accelerometer achieves ultra-high performance with a nonlinearity of 0.04%. The device also demonstrates a sensitivity of 13.77 μm/g within a measurement range of ±1.6 g, with a noise floor of 9.6×10-7 g/√Hz. The integration of STG technology with the MEMS resonator offers a scalable solution for high-precision, field-deployable accelerometer measurements, greatly improving measurement linearity and traceability.


  • Comparison measurements of natural constants based on laser-focused atomic deposition and extreme ultraviolet interference lithography

    by Xiao Deng, Zhaohui Tang, Song Song, Guangxu Xiao, Zhijun Yin, Junyu Shen, Dongbai Xue, Yuying Xie, Xiong Dun, Xinbin Cheng, et al.

    Traceability is the foundation of accuracy and consistency in dimensional metrology. Meter in the International System of Units is defined and reproduced by natural constants. Comparing the differences in traceability approaches based on different natural constants can better understand the real size of manufacturing structures. This paper compares the consistency of three traceability approaches based on chromium atomic transition wavelength, iodine-stabilized laser wavelength (top-down approach), and silicon lattice spacing (bottom-up approach) in nanoscale dimensional metrology. For comparison, the measured objects are silicon gratings manufactured by laser-focused atomic deposition (LFAD) and extreme ultraviolet interference lithography (EUV IL). Notably, the pitch of the silicon gratings can be traced from the transition wavelength of chromium (7S3→ 7P4, λ = 425.5533 nm). For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 1, the expected pitch of the silicon grating is λ 4 . The pitch of the silicon grating is measured using a top-down (metrological atomic force microscope) approach, and the deviation between the measured result and the pitch based on the transition wavelength of chromium is 0.1 nm. For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 2, the expected pitch of the silicon grating is λ 8 . This silicon grating is measured using a bottom-up approach, and the deviation between the measured results and the pitch based on the transition wavelength of chromium is 0.2 nm. This study provides a feasible solution for integrating various measurement methods and different traceability approaches at the nanoscale. It demonstrates the potential and feasibility of a nanoscale dimensional metrology traceability chain based on self-traceable gratings.


  • A Method to Calibrate Accelerometers by Laser Self-Mixing Self-Traceable Grating Interferometry

    by Song Song, Zhikun Chang, Haoran Zhang, Xiaoling Han, Xiaoyu Shen, Pengfei Niu, Jing Yu, Xiao Deng

    As key devices in dynamic measurement, the precision and accuracy of accelerometers not only directly influence the performance of the equipment they are part of but also can impact user safety. Accelerometers must undergo pre-factory calibration and regular recalibration during usage, attributable to factors like manufacturing and installation errors, as well as environmental conditions. Currently, the majority of initial calibrations for accelerometers depend on laser interferometry measurement technology. However, ensuring the accuracy and stability of laser measurements is difficult, since laser wavelengths are easily affected by environmental factors, and on-site traceability calibration presents challenges. In this paper, we utilize a chromium atom self-traceable grating, whose pitch is traceable to natural constants (grating pitch d=212.78nm), and combine it with a laser self-mixing grating interferometer and vibrator calibration technology, introducing a novel method for accelerometer calibration. The system’s efficacy was validated using a commercial accelerometer as a test subject. This calibration technique not only promises to enhance the accuracy and interference resistance of the vibrator calibration method but also addresses the issue of on-site traceability.


  • Open Access

    Research on Tip Characterization Techniques Based on Two-Dimensional Self-Traceable Nano-Gratings

    by Yingfan Xiong, Jinming Gou, Zhaohui Tang, Guangxu Xiao, Lihua Lei, Song Song, Xiao Deng, Xinbin Cheng

    The characterization of scanning tip morphology is crucial for accurate linewidth measurements. Conventional rectangular characterizers are affected by lateral distortion caused by the nonlinearities in AFM scanning, leading to errors between the actual characterization results and the true values. In this study, we innovatively developed self-traceable two-dimensional nano-gratings using chromium atomic deposition technology and extreme ultraviolet interference lithography. We used this structure as a characterizer for conducting scanning tip characterizations.This paper analyzed the periodic stability of the grating sample during scanning and corrected the lateral distortion of atomic force microscopy (AFM) at scan scales of 0.5 µm and 1 µm based on its self-traceable characteristics. Additionally, we extracted the angle information of the scanning tip in the X direction and Y direction within a scan scale of 0.5 µm. The results demonstrate that the two-dimensional grating sample exhibited excellent periodic stability during scanning. The characterization errors for the tip’s X direction and Y direction angles are within ±2°, showing high consistency. This study highlights that self-traceable two-dimensional grating samples have the capability for in situ bidirectional characterization of tip information, providing a creative solution for the development of new-style tip characterizers.


  • Open Access

    Large‐fragment insertion activates gene GaFZ (Ga08G0121) and is associated with the fuzz and trichome reduction in cotton (Gossypium arboreum)

    by Xiaoyang Wang, Yuchen Miao, Yingfan Cai, Gaofei Sun, Yinhua Jia, Song Song, Zhaoe Pan, Yuanming Zhang, Liyuan Wang, Guoyong Fu, et al.

    Summary: Cotton seeds are typically covered by lint and fuzz fibres. Natural ‘fuzzless’ mutants are an ideal model system for identifying genes that regulate cell initiation and elongation. Here, using a genome‐wide association study (GWAS), we identified a ~ 6.2 kb insertion, larINDELFZ, located at the end of chromosome 8, composed of a ~ 5.0 kb repetitive sequence and a ~ 1.2 kb fragment translocated from chromosome 12 in fuzzless Gossypium arboreum. The presence of larINDELFZ was associated with a fuzzless seed and reduced trichome phenotypes in G. arboreum. This distant insertion was predicted to be an enhancer, located ~ 18 kb upstream of the dominant‐repressor GaFZ (Ga08G0121). Ectopic overexpression of GaFZ in Arabidopsis thaliana and G. hirsutum suggested that GaFZ negatively modulates fuzz and trichome development. Co‐expression and interaction analyses demonstrated that GaFZ might impact fuzz fibre/trichome development by repressing the expression of genes in the very‐long‐chain fatty acid elongation pathway. Thus, we identified a novel regulator of fibre/trichome development while providing insights into the importance of noncoding sequences in cotton.


  • Open Access

    State-of-the-Art Technologies for Understanding Brassinosteroid Signaling Networks

    by Haijiao Wang, Song Song, Huaqiang Cheng, Yan-Wen Tan

    Brassinosteroids, the steroid hormones of plants, control physiological and developmental processes through its signaling pathway. The major brassinosteroid signaling network components, from the receptor to transcription factors, have been identified in the past two decades. The development of biotechnologies has driven the identification of novel brassinosteroid signaling components, even revealing several crosstalks between brassinosteroid and other plant signaling pathways. Herein, we would like to summarize the identification and improvement of several representative brassinosteroid signaling components through the development of new technologies, including brassinosteroid-insensitive 1 (BRI1), BRI1-associated kinase 1 (BAK1), BR-insensitive 2 (BIN2), BRI1 kinase inhibitor 1 (BKI1), BRI1-suppressor 1 (BSU1), BR signaling kinases (BSKs), BRI1 ethyl methanesulfonate suppressor 1 (BES1), and brassinazole resistant 1 (BZR1). Furthermore, improvement of BR signaling knowledge, such as the function of BKI1, BES1 and its homologous through clustered regularly interspaced short palindromic repeats (CRISPR), the regulation of BIN2 through single-molecule methods, and the new in vivo interactors of BIN2 identified by proximity labeling are described. Among these technologies, recent advanced methods proximity labeling and single-molecule methods will be reviewed in detail to provide insights to brassinosteroid and other phytohormone signaling pathway studies.


  • Isolation and Genome Phylogenetic Analysis of Arthropod-Borne Viruses, Including Akabane Virus, from Mosquitoes Collected in Hunan Province, China

    by Yuxi Cao, Shihong Fu, Song Song, Liang Cai, Hong Zhang, Lidong Gao, Lei Cao, Minghua Li, Xiaoyan Gao, Ying He, et al.

    This study investigated the abundance of mosquitoes and circulation of mosquito-borne arboviruses from 16 villages in 8 cities of Hunan Province, China, in July–August of 2010 and in August of 2011. In total, 16,076 mosquitoes consisting of seven species from four genera were collected by ultraviolet-light trap. Culex quinquefasciatus was the most common species, accounting for 50.63% (8140/16,076) of the total. Anopheles sinensis (24.26%, 3900/16,076) made up the second most common species, followed by Culex tritaeniorhynchus (9.76%, 1569/16,076). The proportions of Culex pipiens pallens, Armigeres subalbatus, and Culex modestus were 6.7%, 5.2%, and 3.31%, respectively. Fourteen Aedes albopictus were detected. The mosquitoes were identified by morphologic characteristics and frozen in liquid nitrogen. The mosquitoes were pooled, triturated, and centrifuged. The clarified supernatant was used to inoculate monolayers of C6/36 and baby hamster kidney-21 cells. We obtained six virus isolates that caused cytopathic effects. Phylogenetic analysis revealed that two isolates were Akabane virus (AKAV, from A. sinensis and C. quinquefasciatus), two isolates were Japanese encephalitis virus (from C. pipiens pallens and C. quinquefasciatus), and two isolates were Tibet orbivirus (from C. quinquefasciatus and C. tritaeniorhynchus). This is the first report of AKAV isolated from A. sinensis and C. quinquefasciatus in nature in China. The detection of AKAV in these species confirms circulation of AKAV in Hunan province and suggests potential challenges to the prevention and control of arthropod-borne animal viruses in mainland China.