Alireza Riazifar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alireza Riazifar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Abbasali Yekta
Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication- Abbasali Yekta
Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication - Ali Mirzajani
Iran University of Medical Sciences
1 shared publication - Alireza Jamali
Rehabilitation Research Center, Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
1 shared publication Amir Asharlous
Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
1 shared publicationAmir Rakhshan
Department of Foreign Languages, Tehran University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 19 December 2025
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 20, 1-8
The Effect of Tinted Filters on the Visual Function of Patients with Retinitis Pigmentosa
Purpose: To investigate the effect of tinted filters on contrast threshold (CT) and visual evoked potentials (VEPs) in patients with retinitis pigmentosa (RP). Methods: In this cross-sectional study, RP patients with best corrected visual acuity better than 1 log MAR were evaluated. The CT was measured using the Freiburg Acuity and Contrast Test, and pattern reversals were analyzed for both time and frequency components. The effects of gray (15% light transmission, 410 nm cutoff), brown (18% light transmission, 410 nm cutoff), and yellow (27% light transmission with a 470 nm cutoff) tinted filters were evaluated and compared. Results: Eighteen participants (mean age 32.78 ± 7.35 years; 72.2% male) were evaluated. The mean CT of Weber was 3.46 ± 3.2%. Yellow filters decreased CT (mean difference [MD]: –0.597%, P = 0.054). Brown filters did not produce a significant change in the CT (MD: 0.233%, P = 0.620), while the gray filters caused a significant increase in the CT (MD: 1.423%, P = 0.004). Mode frequency (Fmod) decreased with gray filters (MD: –2.33%, P = 0.004). The latency and amplitude of VEPs improved with yellow filters (P < 0.05) but worsened with gray filters (P < 0.05). Additionally, the spherical equivalent showed an inverse correlation with CT in patients with RP (r = –0.997, P < 0.001). Conclusion: Using tinted filters as a low-vision aid can modify contrast sensitivity and both frequency and time domains of VEPs in patients with RP. Yellow filters appear to improve visual function, whereas gray filters may worsen it.
- 19 December 2025
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 20, 1-8
Open AccessThe Effect of Tinted Filters on the Visual Function of Patients with Retinitis Pigmentosa
Purpose: To investigate the effect of tinted filters on contrast threshold (CT) and visual evoked potentials (VEPs) in patients with retinitis pigmentosa (RP). Methods: In this cross-sectional study, RP patients with best corrected visual acuity better than 1 log MAR were evaluated. The CT was measured using the Freiburg Acuity and Contrast Test, and pattern reversals were analyzed for both time and frequency components. The effects of gray (15% light transmission, 410 nm cutoff), brown (18% light transmission, 410 nm cutoff), and yellow (27% light transmission with a 470 nm cutoff) tinted filters were evaluated and compared. Results: Eighteen participants (mean age 32.78 ± 7.35 years; 72.2% male) were evaluated. The mean CT of Weber was 3.46 ± 3.2%. Yellow filters decreased CT (mean difference [MD]: –0.597%, P = 0.054). Brown filters did not produce a significant change in the CT (MD: 0.233%, P = 0.620), while the gray filters caused a significant increase in the CT (MD: 1.423%, P = 0.004). Mode frequency (Fmod) decreased with gray filters (MD: –2.33%, P = 0.004). The latency and amplitude of VEPs improved with yellow filters (P < 0.05) but worsened with gray filters (P < 0.05). Additionally, the spherical equivalent showed an inverse correlation with CT in patients with RP (r = –0.997, P < 0.001). Conclusion: Using tinted filters as a low-vision aid can modify contrast sensitivity and both frequency and time domains of VEPs in patients with RP. Yellow filters appear to improve visual function, whereas gray filters may worsen it.
- Open Access
- 10 March 2024
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 19 (1) , 82-87
The Effect of Cycloplegia on Ocular Alignment and AC/A Ratio
Purpose: The present study sets out to investigate the effect of cyclopentolate-induced cycloplegia on distance and near deviation and the accommodative convergence/accommodation (AC/A) ratio. Methods: This prospective study was performed on 30 subjects. The inclusion criteria included a lack of any active ocular pathology and systemic diseases, no history of ocular surgery, and nonuse of various medications. Refraction, near and distance deviation were measured for all subjects, and the same examinations were repeated after the administration of two drops of cyclopentolate 1% to both eyes. Results: The obtained data from 30 subjects, including 19 males, with a mean age of 22.53 ± 1.74 years were analyzed. The mean ± SD of near deviation in dry and cycloplegic conditions were – 6.9 ± 8.1 and +6.4 ± 9.1 prism diopters, respectively, which were statistically significant (P < 0.001). Distance deviation in cycloplegic conditions demonstrated an average difference of 0.8 prism diopters, compared to dry conditions (P < 0.001). AC/A ratios were 4.7 ± 2.5 and 9.7 ± 3.9 (Δ/D) in non-cycloplegic and cycloplegic conditions, respectively, which was a statistically significant difference (P < 0.001). The multiple regression indicated that among all under study variables, refraction (B coefficient: –2.4; P < 0.001) and near pre-cycloplegic deviation (B coefficient: 0.56; P < 0.001) were significantly associated with post-cycloplegic near deviation. Conclusion: The results of this study indicated that cycloplegia causes a considerable esophoric shift in near deviation and a negligible esophoric shift in distance deviation. As a result, the AC/A ratio demonstrated a significant increase due to unequal changes in near and distance deviation.
- 10 March 2024
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 19 (1) , 82-87
Open AccessThe Effect of Cycloplegia on Ocular Alignment and AC/A Ratio
Purpose: The present study sets out to investigate the effect of cyclopentolate-induced cycloplegia on distance and near deviation and the accommodative convergence/accommodation (AC/A) ratio. Methods: This prospective study was performed on 30 subjects. The inclusion criteria included a lack of any active ocular pathology and systemic diseases, no history of ocular surgery, and nonuse of various medications. Refraction, near and distance deviation were measured for all subjects, and the same examinations were repeated after the administration of two drops of cyclopentolate 1% to both eyes. Results: The obtained data from 30 subjects, including 19 males, with a mean age of 22.53 ± 1.74 years were analyzed. The mean ± SD of near deviation in dry and cycloplegic conditions were – 6.9 ± 8.1 and +6.4 ± 9.1 prism diopters, respectively, which were statistically significant (P < 0.001). Distance deviation in cycloplegic conditions demonstrated an average difference of 0.8 prism diopters, compared to dry conditions (P < 0.001). AC/A ratios were 4.7 ± 2.5 and 9.7 ± 3.9 (Δ/D) in non-cycloplegic and cycloplegic conditions, respectively, which was a statistically significant difference (P < 0.001). The multiple regression indicated that among all under study variables, refraction (B coefficient: –2.4; P < 0.001) and near pre-cycloplegic deviation (B coefficient: 0.56; P < 0.001) were significantly associated with post-cycloplegic near deviation. Conclusion: The results of this study indicated that cycloplegia causes a considerable esophoric shift in near deviation and a negligible esophoric shift in distance deviation. As a result, the AC/A ratio demonstrated a significant increase due to unequal changes in near and distance deviation.