Yusen Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yusen Wu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Hui Zhang
3 shared publications- Yongqi Hou
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments School of Mechanical Engineering, Southeast University , Nanjing 211189, China
2 shared publications Feilong Mao
1 shared publication- Feilong Mao
Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments School of Mechanical Engineering, Southeast University , Nanjing 211189, China
1 shared publication Huizhen Lu
1 shared publicationJian Jing
1 shared publication
Latest Publications
- 18 November 2024
- Published by Elsevier in Applied Acoustics
- Vol. 229
Ultrasonic-based in-service monitoring of density for organic polymeric buried pipelines
- 18 November 2024
- Published by Elsevier in Applied Acoustics
- Vol. 229
Ultrasonic-based in-service monitoring of density for organic polymeric buried pipelines
- 8 April 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (15)
Broadband tunable acoustic impedance matching using gradient-distributed piezoelectric structure
In this paper, we propose a broadband tunable acoustic matching layer (BTAML) comprising an array of piezoelectric elements with non-uniform gradient shunt circuits (NGSCs). The effective impedance of the BTAML can be controlled in real time by regulating the parameters of NGSCs. The theoretical results demonstrate that BTAML is capable of adjusting impedance from 1.5 to 20 MRayl and has a broad bandwidth compared with the traditional matching layer. Furthermore, we experimentally verified the acoustic transmission property of the BTAML, and good agreement was achieved with numerical simulations. The approach can significantly promote research on tunable acoustic matching and offer effective impedance matching layers with a broad bandwidth in industrial applications.
- 8 April 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (15)
Broadband tunable acoustic impedance matching using gradient-distributed piezoelectric structure
In this paper, we propose a broadband tunable acoustic matching layer (BTAML) comprising an array of piezoelectric elements with non-uniform gradient shunt circuits (NGSCs). The effective impedance of the BTAML can be controlled in real time by regulating the parameters of NGSCs. The theoretical results demonstrate that BTAML is capable of adjusting impedance from 1.5 to 20 MRayl and has a broad bandwidth compared with the traditional matching layer. Furthermore, we experimentally verified the acoustic transmission property of the BTAML, and good agreement was achieved with numerical simulations. The approach can significantly promote research on tunable acoustic matching and offer effective impedance matching layers with a broad bandwidth in industrial applications.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Advanced Orthogonal Frequency and Phase Modulated Waveform for Ultrasonic Phased Array TFM Detection in CFRP Composites
Phased array ultrasonic total focusing method (TFM) imaging has attracted much attention due to its high detection image resolution and large dynamic range. However, due to the small emission energy of its single element, the echo signal is weak and susceptible to noise interference, resulting in a relatively low signal-to-noise ratio (SNR). Especially when detecting high sound attenuation carbon fiber reinforced polymer (CFRP) composites, the signal amplitude can decrease with depth to a level lower than the electronic noise introduced by the signal acquisition system. To solve this problem, a new imaging algorithm was proposed that combines the Golay code excitation using linear frequency modulation (LFM) signal as the carrier with the TFM algorithm (LFM-Golay TFM). Meanwhile, in order to further overcome the disadvantage of the LFM-Golay code encoding excitation method requiring two excitations, an AB code encoding excitation conversion factor was introduced, two sets of echo data were obtained through processing single excitation, TFM imaging based on LFM-Golay code single excitation (IMP-LFM-Golay TFM) is realized. Simulation and experimental studies were conducted to compare the TFM imaging performance of single-pulse excitation (Pulse TFM), Barker coding excitation (Barker TFM), LFM excitation (LFM TFM), and improved LFM-Golay coding excitation. The results show that IMP-LFM-Golay TFM has the best SNR, axial resolution, and depth resolution.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Advanced Orthogonal Frequency and Phase Modulated Waveform for Ultrasonic Phased Array TFM Detection in CFRP Composites
Phased array ultrasonic total focusing method (TFM) imaging has attracted much attention due to its high detection image resolution and large dynamic range. However, due to the small emission energy of its single element, the echo signal is weak and susceptible to noise interference, resulting in a relatively low signal-to-noise ratio (SNR). Especially when detecting high sound attenuation carbon fiber reinforced polymer (CFRP) composites, the signal amplitude can decrease with depth to a level lower than the electronic noise introduced by the signal acquisition system. To solve this problem, a new imaging algorithm was proposed that combines the Golay code excitation using linear frequency modulation (LFM) signal as the carrier with the TFM algorithm (LFM-Golay TFM). Meanwhile, in order to further overcome the disadvantage of the LFM-Golay code encoding excitation method requiring two excitations, an AB code encoding excitation conversion factor was introduced, two sets of echo data were obtained through processing single excitation, TFM imaging based on LFM-Golay code single excitation (IMP-LFM-Golay TFM) is realized. Simulation and experimental studies were conducted to compare the TFM imaging performance of single-pulse excitation (Pulse TFM), Barker coding excitation (Barker TFM), LFM excitation (LFM TFM), and improved LFM-Golay coding excitation. The results show that IMP-LFM-Golay TFM has the best SNR, axial resolution, and depth resolution.