Ni Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ni Fang has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Ran Chen
PLAC, Key Laboratory of Quark Lepton Physics (MOE), Central China Normal University, No. 152 Luoyu Road, Wuhan, Hubei 430079, China
6 shared publicationsShiqiang Zhou
PLAC, Key Laboratory of Quark Lepton Physics (MOE), Central China Normal University, No. 152 Luoyu Road, Wuhan, Hubei 430079, China
5 shared publications- Hui Wang
PLAC, Key Laboratory of Quark Lepton Physics (MOE), Central China Normal University, Wuhan, China
4 shared publications Xiangming Sun
Central China Normal University
4 shared publications- Zhuo Zhou
PLAC, Key Laboratory of Quark and Lepton Physics (MOE), Central China Normal University, Wuhan, China
4 shared publications Dong Wang
PLAC, Key Laboratory of Quark and Lepton Physics (MOE), Central China Normal University, Wuhan, China
3 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3824-3836
Readout Electronics Firmware for the Beam Particle Monitor in the HIRFL-CSR External-Target Experiment
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3824-3836
Readout Electronics Firmware for the Beam Particle Monitor in the HIRFL-CSR External-Target Experiment
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01044
A high-precision time measurement circuit for pixel detectors using a two-stage timing scheme
This paper presents a two-stage time measurement architecture that combines coarse timing and fine timing to improve time measurement accuracy. Coarse timing provides a global clock reference through a 10 MHz counter, while fine timing employs a time-to-amplitude converter (TAC) to overcome the limitations of counter accuracy and achieve higher time resolution. The pixel array in the design consists of 128 × 128 pixels, with each pixel unit measuring 40 μm × 45 μm, integrating a low-noise charge-sensitive amplifier (CSA), a comparator, and a TAC. Through this architecture, the proposed solution achieves nanosecond-level time resolution, effectively enhancing the time measurement accuracy of particle collision events. Experimental results indicate that the CSA achieves a charge conversion gain of 101.5 μV/e - , an input dynamic range of 0 to 18 ke - , and a non-linearity error below 1.56%, with an equivalent noise charge (ENC) of approximately 35 e - , ensuring excellent low-noise performance. Furthermore, the time measurement path achieves a time accuracy of approximately 1.33 ns with an effective range of 100 ns, validating its capability for high-precision timing applications. This work provides a viable solution for applying the Topmetal chip to low-energy X-ray polarization time measurement, as well as other high-precision timing applications.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01044
A high-precision time measurement circuit for pixel detectors using a two-stage timing scheme
This paper presents a two-stage time measurement architecture that combines coarse timing and fine timing to improve time measurement accuracy. Coarse timing provides a global clock reference through a 10 MHz counter, while fine timing employs a time-to-amplitude converter (TAC) to overcome the limitations of counter accuracy and achieve higher time resolution. The pixel array in the design consists of 128 × 128 pixels, with each pixel unit measuring 40 μm × 45 μm, integrating a low-noise charge-sensitive amplifier (CSA), a comparator, and a TAC. Through this architecture, the proposed solution achieves nanosecond-level time resolution, effectively enhancing the time measurement accuracy of particle collision events. Experimental results indicate that the CSA achieves a charge conversion gain of 101.5 μV/e - , an input dynamic range of 0 to 18 ke - , and a non-linearity error below 1.56%, with an equivalent noise charge (ENC) of approximately 35 e - , ensuring excellent low-noise performance. Furthermore, the time measurement path achieves a time accuracy of approximately 1.33 ns with an effective range of 100 ns, validating its capability for high-precision timing applications. This work provides a viable solution for applying the Topmetal chip to low-energy X-ray polarization time measurement, as well as other high-precision timing applications.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , C12004
Front-end circuit optimization of CMOS pixel detectors for X-ray polarization measurements
The Topmetal CMOS pixel detectors employ metal electrodes for direct charge collection and have been widely adopted in gas pixel detectors (GPDs) for X-ray polarization measurements. The performance of these detectors, particularly in terms of dynamic range, event rate capability, and energy measurement accuracy, is critical to achieving high detection efficiency. This work presents a detailed analysis of the pixel front-end circuit architecture of Topmetal detectors and introduces a series of optimizations to enhance their performance. To validate the proposed improvements, a prototype pixel front-end ASIC was designed and fabricated using the GSMC 130 nm CMOS process. Each pixel primarily consists of a charge sensitive amplifier (CSA), a peak detect and hold (PDH) circuit, and a two-stage buffer. Simulation results demonstrate that the optimized pixel achieves an equivalent noise charge (ENC) of 33.25 e - + 0.42 e - /fF, a charge-voltage conversion gain of 69 μ V/e - , and a dynamic range of 26 k e - . Compared to previous Topmetal generations, the optimized pixel exhibits an extended dynamic range, improved linearity, enhanced energy measurement accuracy, and increased event rate capability (supporting up to 10 kcps), demonstrating its potential for large-scale integration in next-generation pixel detectors for X-ray polarization detection missions.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , C12004
Front-end circuit optimization of CMOS pixel detectors for X-ray polarization measurements
The Topmetal CMOS pixel detectors employ metal electrodes for direct charge collection and have been widely adopted in gas pixel detectors (GPDs) for X-ray polarization measurements. The performance of these detectors, particularly in terms of dynamic range, event rate capability, and energy measurement accuracy, is critical to achieving high detection efficiency. This work presents a detailed analysis of the pixel front-end circuit architecture of Topmetal detectors and introduces a series of optimizations to enhance their performance. To validate the proposed improvements, a prototype pixel front-end ASIC was designed and fabricated using the GSMC 130 nm CMOS process. Each pixel primarily consists of a charge sensitive amplifier (CSA), a peak detect and hold (PDH) circuit, and a two-stage buffer. Simulation results demonstrate that the optimized pixel achieves an equivalent noise charge (ENC) of 33.25 e - + 0.42 e - /fF, a charge-voltage conversion gain of 69 μ V/e - , and a dynamic range of 26 k e - . Compared to previous Topmetal generations, the optimized pixel exhibits an extended dynamic range, improved linearity, enhanced energy measurement accuracy, and increased event rate capability (supporting up to 10 kcps), demonstrating its potential for large-scale integration in next-generation pixel detectors for X-ray polarization detection missions.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3407-3415
A Novel Readout Scheme With Controllable Delay Chains for High-Precision Time Resolution in Pixel Detectors
With the increasing deployment of pixel detectors in particle physics, imaging systems, and other high-precision applications, improving time resolution and signal processing speed has become a pressing challenge. Traditional readout schemes often struggle with the trade-off between accuracy and efficiency. This study proposes a novel readout architecture that incorporates controllable delay chains to facilitate multi-directional signal propagation, enabling precise event localization through transmission path differences. Each pixel circuit integrates a low-noise charge-sensitive amplifier, a comparator, and a tunable delay unit, collectively enhancing signal fidelity and timing accuracy. Fabricated using the TSMC 180 nm CMOS process, two configurations are implemented: a four-directional delay chain (ASIC-I) and a two-directional variant (ASIC-II), tailored to varying signal propagation needs. Experimental results demonstrate that the ASIC-I chip, configured as a 3 × 3 pixel array, achieves a per-pixel time resolution of 52.8 ps. The delay unit provides 7 adjustable levels with a range from 2.27 ns to 15.55 ns. The measured system time precision (RMS jitter) is 160 ps. Reliability tests under varying process, voltage, and temperature (PVT) conditions show robust performance, with a temperature coefficient ranging from 7 ps/°C to 44 ps/°C. These results validate the proposed scheme’s feasibility and robustness, offering promising potential for high-speed, high-resolution particle detection and real-time data acquisition systems.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3407-3415
A Novel Readout Scheme With Controllable Delay Chains for High-Precision Time Resolution in Pixel Detectors
With the increasing deployment of pixel detectors in particle physics, imaging systems, and other high-precision applications, improving time resolution and signal processing speed has become a pressing challenge. Traditional readout schemes often struggle with the trade-off between accuracy and efficiency. This study proposes a novel readout architecture that incorporates controllable delay chains to facilitate multi-directional signal propagation, enabling precise event localization through transmission path differences. Each pixel circuit integrates a low-noise charge-sensitive amplifier, a comparator, and a tunable delay unit, collectively enhancing signal fidelity and timing accuracy. Fabricated using the TSMC 180 nm CMOS process, two configurations are implemented: a four-directional delay chain (ASIC-I) and a two-directional variant (ASIC-II), tailored to varying signal propagation needs. Experimental results demonstrate that the ASIC-I chip, configured as a 3 × 3 pixel array, achieves a per-pixel time resolution of 52.8 ps. The delay unit provides 7 adjustable levels with a range from 2.27 ns to 15.55 ns. The measured system time precision (RMS jitter) is 160 ps. Reliability tests under varying process, voltage, and temperature (PVT) conditions show robust performance, with a temperature coefficient ranging from 7 ps/°C to 44 ps/°C. These results validate the proposed scheme’s feasibility and robustness, offering promising potential for high-speed, high-resolution particle detection and real-time data acquisition systems.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (12) , 2578-2587
Low-Energy X-Ray Polarization Detector Detection Unit Prototype
The Low-Energy X-ray Polarization Detector (LPD) is a large-area and wide field of view X-ray polarimeter planned to be installed on the China Space Station. The LPD is designed to measure the polarization of gamma bursts and their early X-ray afterglows, facilitating studies of celestial bodies and radiation mechanisms at the centers of gamma bursts. The LPD consists of 15 detection units with identical structure and function. A detection unit prototype was developed, featuring six pixel detectors compactly placed on a bonding and front-end electronics board with an effective detection area of 27.36 cm 2 . Each pixel detector has 16 analog output channels, after which data is amplified, digitized, and transmitted via the board-to-board connector to the data acquisition board for processing. The prototype also includes an internal high-voltage circuit with up to -4 kV voltages. The test results indicate that the detection unit prototype can simultaneously read data from 96 channels of pixel detectors with an equivalent charge noise of 49.49 e - . It features comprehensive power management, offers configurable data compression, storage, and encoding, and meets all functional requirements of the detection unit.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (12) , 2578-2587
Low-Energy X-Ray Polarization Detector Detection Unit Prototype
The Low-Energy X-ray Polarization Detector (LPD) is a large-area and wide field of view X-ray polarimeter planned to be installed on the China Space Station. The LPD is designed to measure the polarization of gamma bursts and their early X-ray afterglows, facilitating studies of celestial bodies and radiation mechanisms at the centers of gamma bursts. The LPD consists of 15 detection units with identical structure and function. A detection unit prototype was developed, featuring six pixel detectors compactly placed on a bonding and front-end electronics board with an effective detection area of 27.36 cm 2 . Each pixel detector has 16 analog output channels, after which data is amplified, digitized, and transmitted via the board-to-board connector to the data acquisition board for processing. The prototype also includes an internal high-voltage circuit with up to -4 kV voltages. The test results indicate that the detection unit prototype can simultaneously read data from 96 channels of pixel detectors with an equivalent charge noise of 49.49 e - . It features comprehensive power management, offers configurable data compression, storage, and encoding, and meets all functional requirements of the detection unit.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 757-764
Design of the Data Acquisition System for the HERD Transition Radiation Detector Prototype
The Transition Radiation Detector (TRD) of the High Energy Cosmic Radiation Detection facility (HERD) utilizes the relationship between high-energy charged particle transition radiation and the Lorentz factor to calibrate the energy of TeV-band protons in HERD calorimeters. It can also independently conduct X-ray observation and monitor Gamma-Ray Bursts. The TRD consists of detector units, front-end electronics (FEE), and a data acquisition (DAQ) system. The DAQ system is responsible for the overall power management of the TRD, communication and triggering between the TRD and HERD, data processing of the detector units, control of multiple modules within the TRD, and in-orbit operation of the whole TRD. Here we report a DAQ system of the TRD prototype, which connects six front-end circuit boards, six high-voltage circuit boards, a turntable device, a HERD trigger system, and HERD electronics. It adopts a structure with separate data and electrical components. The power sections of the front-end electronics, high-voltage, turntable device, and DAQ system are designed as a power circuit board, while the FEE data transmission and telemetry, triggering, main controller, storage, and communication are designed as a data circuit board. We tested the DAQ system at the European Organization for Nuclear Research, and the results show that the system can meet the requirements of the TRD prototype in terms of power, communication, data processing, and overall control. Additionally, we demonstrate that the DAQ system has been redundantly designed to enhance adaptability.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 757-764
Design of the Data Acquisition System for the HERD Transition Radiation Detector Prototype
The Transition Radiation Detector (TRD) of the High Energy Cosmic Radiation Detection facility (HERD) utilizes the relationship between high-energy charged particle transition radiation and the Lorentz factor to calibrate the energy of TeV-band protons in HERD calorimeters. It can also independently conduct X-ray observation and monitor Gamma-Ray Bursts. The TRD consists of detector units, front-end electronics (FEE), and a data acquisition (DAQ) system. The DAQ system is responsible for the overall power management of the TRD, communication and triggering between the TRD and HERD, data processing of the detector units, control of multiple modules within the TRD, and in-orbit operation of the whole TRD. Here we report a DAQ system of the TRD prototype, which connects six front-end circuit boards, six high-voltage circuit boards, a turntable device, a HERD trigger system, and HERD electronics. It adopts a structure with separate data and electrical components. The power sections of the front-end electronics, high-voltage, turntable device, and DAQ system are designed as a power circuit board, while the FEE data transmission and telemetry, triggering, main controller, storage, and communication are designed as a data circuit board. We tested the DAQ system at the European Organization for Nuclear Research, and the results show that the system can meet the requirements of the TRD prototype in terms of power, communication, data processing, and overall control. Additionally, we demonstrate that the DAQ system has been redundantly designed to enhance adaptability.
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 231-239
Optimization of Energy Resolution in Topmetal-II‾ Pixel Detector: An Exploration of Neural Network and Curve-Fitting Strategies
This study aims to enhance the energy resolution of the Topmetal-II − pixel detector, which is pivotal for capturing soft X-ray signals and accurately measuring X-ray polarization. To achieve this, we used convolutional neural networks (CNNs) and curve-fitting techniques. The CNNs were trained on energy data from the Topmetal-II − detector to predict the peak voltage of waveforms at different amplitudes. Additionally, we employed curve-fitting methods to develop a response model for the detector. We collected energy data from the Topmetal-II − using high-precision oscilloscopes, with data sampled at equidistant intervals to simulate a 40 MHz sampling rate analog-to-digital converter. Our findings indicate that a denoising autoencoder with five encoding layers and five decoding layers, combined with a two-layer regression network, significantly improved performance. The energy deviation was reduced from 15.4 mV to 0.41 mV, and the energy resolution was enhanced from 24.26 mV to 5.09 mV, representing an approximate 4.77-fold improvement. In contrast, the curve fitting increases the energy peak from 27.04 mV to 32.05 mV at an input of 350 mV, resulting in a slightly improved energy resolution. These results demonstrate substantial advancements in soft X-ray detection technology, underscoring the potential for more precise and reliable measurements in low-energy X-ray polarization detector experiments.
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 231-239
Optimization of Energy Resolution in Topmetal-II‾ Pixel Detector: An Exploration of Neural Network and Curve-Fitting Strategies
This study aims to enhance the energy resolution of the Topmetal-II − pixel detector, which is pivotal for capturing soft X-ray signals and accurately measuring X-ray polarization. To achieve this, we used convolutional neural networks (CNNs) and curve-fitting techniques. The CNNs were trained on energy data from the Topmetal-II − detector to predict the peak voltage of waveforms at different amplitudes. Additionally, we employed curve-fitting methods to develop a response model for the detector. We collected energy data from the Topmetal-II − using high-precision oscilloscopes, with data sampled at equidistant intervals to simulate a 40 MHz sampling rate analog-to-digital converter. Our findings indicate that a denoising autoencoder with five encoding layers and five decoding layers, combined with a two-layer regression network, significantly improved performance. The energy deviation was reduced from 15.4 mV to 0.41 mV, and the energy resolution was enhanced from 24.26 mV to 5.09 mV, representing an approximate 4.77-fold improvement. In contrast, the curve fitting increases the energy peak from 27.04 mV to 32.05 mV at an input of 350 mV, resulting in a slightly improved energy resolution. These results demonstrate substantial advancements in soft X-ray detection technology, underscoring the potential for more precise and reliable measurements in low-energy X-ray polarization detector experiments.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03047
50.3 ps time resolution and an 11-channel time measuring chip for Topmetal detectors
The Topmetal detector, utilized in this investigation, is a direct-type CMOS pixel sensor known for its distinctive feature of employing exposed metal at the top of each pixel to directly capture external charged particles. This method generates electrical signals through the induction of charge. At present, it is mainly used in gas pixel detector(GPD) and particle beam monitoring. In this paper, we present a new front-end design aimed at enhancing the capabilities of the Topmetal pixel detector. The focus is on incorporating a Time-Digital Conversion (TDC) ASIC into the front-end, with the objective of achieving high-precision time measurement in addition to superior position resolution. The function of the TDC is achieved by the two reverse delay chains, 11 edge acquisition circuits Time-to-Amplitude Converter (TAC), analog gate, weight count module, and Wilkinson Analog-to-Digital Converter (ADC). Coarse time measurement is implemented based on a counter with a working frequency of 500 MHz, and fine time measurement is implemented by the combination of TAC and ADC. The design prototype was taped out with the GSMCR130 nm technology. Test results show that this circuit can handle up to 11 consecutive cases, with the minimum time interval of adjacent cases being 500 ps and the bin size up to 2 ps. The time measurement precision is better than 50.3 ps RMS and the PVT(Process Voltage Temperature) robustness of the input delay chain circuit is validated, showing the stable performance of the design.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03047
50.3 ps time resolution and an 11-channel time measuring chip for Topmetal detectors
The Topmetal detector, utilized in this investigation, is a direct-type CMOS pixel sensor known for its distinctive feature of employing exposed metal at the top of each pixel to directly capture external charged particles. This method generates electrical signals through the induction of charge. At present, it is mainly used in gas pixel detector(GPD) and particle beam monitoring. In this paper, we present a new front-end design aimed at enhancing the capabilities of the Topmetal pixel detector. The focus is on incorporating a Time-Digital Conversion (TDC) ASIC into the front-end, with the objective of achieving high-precision time measurement in addition to superior position resolution. The function of the TDC is achieved by the two reverse delay chains, 11 edge acquisition circuits Time-to-Amplitude Converter (TAC), analog gate, weight count module, and Wilkinson Analog-to-Digital Converter (ADC). Coarse time measurement is implemented based on a counter with a working frequency of 500 MHz, and fine time measurement is implemented by the combination of TAC and ADC. The design prototype was taped out with the GSMCR130 nm technology. Test results show that this circuit can handle up to 11 consecutive cases, with the minimum time interval of adjacent cases being 500 ps and the bin size up to 2 ps. The time measurement precision is better than 50.3 ps RMS and the PVT(Process Voltage Temperature) robustness of the input delay chain circuit is validated, showing the stable performance of the design.