Takashi Notake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takashi Notake has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Minamide
RIKEN Center for Advanced Photonics, RIKEN, Sendai, JAPAN
6 shared publications - Yuma Takida
RIKEN Center for Advanced Photonics, RIKEN, Sendai, JAPAN
5 shared publications - Shin Kubo
Dept. Math. and Phys. Sciences, College of Science and Technology, Chubu University, Kasugai, Japan
4 shared publications - Takashi Shimozuma
National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
4 shared publications - Hiroe Igami
National Institute for Fusion Science, Gifu, Japan
3 shared publications - Kouji Nawata
RIKEN (Japan)
3 shared publications
Latest Publications
- Open Access
- 18 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (12)
High-repetition-rate injection-seeded terahertz-wave parametric generation pumped by a 1.5 μm sub-nanosecond laser
Injection-seeded terahertz (THz)-wave parametric generation (is-TPG) using a nonlinear optical crystal of MgO-doped lithium niobate (MgO:LiNbO3) has made it possible to obtain THz waves with high peak powers and narrow linewidths. To achieve stable THz-wave generation from the MgO:LiNbO3 crystal under strong excitation, the photorefractive effect in the MgO:LiNbO3 crystal would be crucial, which could be eliminated by using a longer pump wavelength than the conventional 1-μm spectral band. Here, we propose to use a 1.5-μm near-infrared (NIR), high-repetition-rate, sub-nanosecond laser source based on a unique Er,Yb:glass planar waveguide amplifier (PWA) as the pump source for the is-TPG using the MgO:LiNbO3 crystal. At a repetition rate of 25 kHz, the frequency tunability from 1.3 to 2.5 THz was obtained with a maximum THz-wave average output power of 0.14 mW at 1.77 THz.
- 18 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (12)
Open AccessHigh-repetition-rate injection-seeded terahertz-wave parametric generation pumped by a 1.5 μm sub-nanosecond laser
Injection-seeded terahertz (THz)-wave parametric generation (is-TPG) using a nonlinear optical crystal of MgO-doped lithium niobate (MgO:LiNbO3) has made it possible to obtain THz waves with high peak powers and narrow linewidths. To achieve stable THz-wave generation from the MgO:LiNbO3 crystal under strong excitation, the photorefractive effect in the MgO:LiNbO3 crystal would be crucial, which could be eliminated by using a longer pump wavelength than the conventional 1-μm spectral band. Here, we propose to use a 1.5-μm near-infrared (NIR), high-repetition-rate, sub-nanosecond laser source based on a unique Er,Yb:glass planar waveguide amplifier (PWA) as the pump source for the is-TPG using the MgO:LiNbO3 crystal. At a repetition rate of 25 kHz, the frequency tunability from 1.3 to 2.5 THz was obtained with a maximum THz-wave average output power of 0.14 mW at 1.77 THz.
- 31 May 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12134, 20-60
Injection-seeded backward terahertz-wave parametric oscillators at 0.3 and 0.5 THz bands for nondestructive imaging applications
We have demonstrated injection-seeded backward terahertz (THz)-wave parametric oscillators (BW-TPOs) based on a slant-strip-type periodically poled lithium niobate (PPLN) crystal with two different poling periods. The BW-TPOs were pumped by sub-nanosecond pump pulses at 1064 nm and designed for generating backward-propagating THz waves around 0.30 and 0.46 THz with PPLN poling periods of 53 and 35 μm, respectively. As a result of an optical injection seeding for the forward-propagating idler wavelength in the BW-TPO process, we achieved over a 1000-fold enhancement in backward-propagating THz-wave output energy, a 63% reduction of the oscillation threshold, and long-term stable operation compared to the unseeded case. Furthermore, we demonstrated that the oscillation frequency of backward-propagating THz waves is continuously tunable in the range of 0.27–0.35 and 0.41–0.52 THz for the poling periods of 53 and 35 μm, respectively, by angle tuning of the PPLN crystal in parallel with seed wavelength tuning. Using the developed injection-seeded BW-TPOs, we also performed the THz-wave imaging test in transmission geometry for various materials, including glass, wood, and liquids.
- 31 May 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12134, 20-60
Injection-seeded backward terahertz-wave parametric oscillators at 0.3 and 0.5 THz bands for nondestructive imaging applications
We have demonstrated injection-seeded backward terahertz (THz)-wave parametric oscillators (BW-TPOs) based on a slant-strip-type periodically poled lithium niobate (PPLN) crystal with two different poling periods. The BW-TPOs were pumped by sub-nanosecond pump pulses at 1064 nm and designed for generating backward-propagating THz waves around 0.30 and 0.46 THz with PPLN poling periods of 53 and 35 μm, respectively. As a result of an optical injection seeding for the forward-propagating idler wavelength in the BW-TPO process, we achieved over a 1000-fold enhancement in backward-propagating THz-wave output energy, a 63% reduction of the oscillation threshold, and long-term stable operation compared to the unseeded case. Furthermore, we demonstrated that the oscillation frequency of backward-propagating THz waves is continuously tunable in the range of 0.27–0.35 and 0.41–0.52 THz for the poling periods of 53 and 35 μm, respectively, by angle tuning of the PPLN crystal in parallel with seed wavelength tuning. Using the developed injection-seeded BW-TPOs, we also performed the THz-wave imaging test in transmission geometry for various materials, including glass, wood, and liquids.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 35, STu5L.4
Optical Up-Conversion-Based Cross-Correlation of Terahertz-Wave Pulses
We characterized a temporal profile of sub-nanosecond terahertz (THz)-wave pulses from an injection-seeded THz-wave parametric generator by using an optical up-conversion-based cross-correlation in a MgO-doped lithium niobate crystal.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 35, STu5L.4
Optical Up-Conversion-Based Cross-Correlation of Terahertz-Wave Pulses
We characterized a temporal profile of sub-nanosecond terahertz (THz)-wave pulses from an injection-seeded THz-wave parametric generator by using an optical up-conversion-based cross-correlation in a MgO-doped lithium niobate crystal.
- 1 January 2021
- Published by Optica Publishing Group
- p. 11p_N404_6
Up-Conversion Cross-Correlation for Characterization of Sub-Nanosecond Terahertz-Wave Pulses
Over the last decade, there has been a growing interest in the development of semiconductor-based THz-wave detectors with high-speed responses for many applications, such as non-destructive sensing and wireless communications.
- 1 January 2021
- Published by Optica Publishing Group
- p. 11p_N404_6
Up-Conversion Cross-Correlation for Characterization of Sub-Nanosecond Terahertz-Wave Pulses
Over the last decade, there has been a growing interest in the development of semiconductor-based THz-wave detectors with high-speed responses for many applications, such as non-destructive sensing and wireless communications.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 1-2
Micro Helical Antenna Made From Biological Algae Spirulina
Micro helical antennas whose resonance correspond to THz frequency region can be fabricated from biological algae spirulina via electroless metal coating. Radiation characteristics of the micro helical antenna are investigated by using THz near-field microscope. Both normal and end-fire mode radiations with different frequency characteristics can be successfully observed in real time.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 1-2
Micro Helical Antenna Made From Biological Algae Spirulina
Micro helical antennas whose resonance correspond to THz frequency region can be fabricated from biological algae spirulina via electroless metal coating. Radiation characteristics of the micro helical antenna are investigated by using THz near-field microscope. Both normal and end-fire mode radiations with different frequency characteristics can be successfully observed in real time.
- 26 February 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (5) , 1294-1297
10 aJ-level sensing of nanosecond pulse below 10 THz by frequency upconversion detection via DAST crystal: more than a 4 K bolometer
By using frequency upconversion detection of terahertz (THz) waves via 4-dimethylamino-N-methyl-4-stilbazolium tosylate (DAST) crystal with an optimized frequency conversion process, ultrahigh sensitivity has been achieved. Direct comparisons with a 4 K bolometer were implemented. By using a simple positive intrinsic negative (PIN) diode without either electrical amplification or optical amplification, frequency upconversion detection can compete with the commercial 4 K bolometer, while by replacing the PIN diode with an avalanche photo diode (APD), it performs more than three orders better than the 4 K bolometer. Based on power calibration, the minimum detectable THz pulse energy is in the order of 10 aJ (9–25 aJ) at 4.3 THz, with a pulse duration of 6 ns. Thus, the minimum number of THz photons that can be detected is down to the order of at room temperature. The current THz detection system gives a noise equivalent power (NEP) in the order of (). Moreover, by switching current optical detectors, the dynamic range is over six orders.- 26 February 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (5) , 1294-1297
10 aJ-level sensing of nanosecond pulse below 10 THz by frequency upconversion detection via DAST crystal: more than a 4 K bolometer
By using frequency upconversion detection of terahertz (THz) waves via 4-dimethylamino-N-methyl-4-stilbazolium tosylate (DAST) crystal with an optimized frequency conversion process, ultrahigh sensitivity has been achieved. Direct comparisons with a 4 K bolometer were implemented. By using a simple positive intrinsic negative (PIN) diode without either electrical amplification or optical amplification, frequency upconversion detection can compete with the commercial 4 K bolometer, while by replacing the PIN diode with an avalanche photo diode (APD), it performs more than three orders better than the 4 K bolometer. Based on power calibration, the minimum detectable THz pulse energy is in the order of 10 aJ (9–25 aJ) at 4.3 THz, with a pulse duration of 6 ns. Thus, the minimum number of THz photons that can be detected is down to the order of at room temperature. The current THz detection system gives a noise equivalent power (NEP) in the order of (). Moreover, by switching current optical detectors, the dynamic range is over six orders.- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07309244,p. 1
Collective Thomson scattering of 77 GHz high power ECRH beam in LHD
The collective Thomson scattering (CTS) is one of the most promising methods for evaluating the ion velocity distribution function. LHD is equipped with eight gyrotrons and with well defined and steerable Gaussian beam injection antenna systems for the plasma production and heating. Such high power Gaussian beam is also attractive for the probing and receiving beams for CTS. One of the newly installed 77 GHz gyrotrons, in particular, can generate more than 1MW over 5 s. This gyrotron is connected to one of the Gaussian mirror antenna set. This antenna set includes one another Gaussian beam mirror suitable for receiving the scattered power from definite scattering volume. A receiver system is installed on the upstream of the transmission line. A heterodyne receiver system consists of a fundamental mixer with fixed local oscillator at 78 GHz. The receiver system of a harmonic mixer with dynamic local frequency tracking capability to the gyrotron frequency will also be installed in the system to improve the IF (intermediate frequency) stability. A notch filter with the 3 dB bandwidth of 300 MHz is used for the front end. First trial of the detection of scattering signal is successfully performed. The calibration and trial of deduction of the bulk ion temperature is reported. CTS using the higher frequency for the higher plasma density region is also under study. Advantages of using higher frequency are the lower expected ECE background and the higher spatial resolution. The gyrotron of the frequency range of 400 GHz is under development for this purpose in university of Fukui. Optimum injection and receiving systems using this gyrotron for CTS in LHD are under design.
- 1 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07309244,p. 1
Collective Thomson scattering of 77 GHz high power ECRH beam in LHD
The collective Thomson scattering (CTS) is one of the most promising methods for evaluating the ion velocity distribution function. LHD is equipped with eight gyrotrons and with well defined and steerable Gaussian beam injection antenna systems for the plasma production and heating. Such high power Gaussian beam is also attractive for the probing and receiving beams for CTS. One of the newly installed 77 GHz gyrotrons, in particular, can generate more than 1MW over 5 s. This gyrotron is connected to one of the Gaussian mirror antenna set. This antenna set includes one another Gaussian beam mirror suitable for receiving the scattered power from definite scattering volume. A receiver system is installed on the upstream of the transmission line. A heterodyne receiver system consists of a fundamental mixer with fixed local oscillator at 78 GHz. The receiver system of a harmonic mixer with dynamic local frequency tracking capability to the gyrotron frequency will also be installed in the system to improve the IF (intermediate frequency) stability. A notch filter with the 3 dB bandwidth of 300 MHz is used for the front end. First trial of the detection of scattering signal is successfully performed. The calibration and trial of deduction of the bulk ion temperature is reported. CTS using the higher frequency for the higher plasma density region is also under study. Advantages of using higher frequency are the lower expected ECE background and the higher spatial resolution. The gyrotron of the frequency range of 400 GHz is under development for this purpose in university of Fukui. Optimum injection and receiving systems using this gyrotron for CTS in LHD are under design.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Feasibility study of collective Thomson scattering in LHD plasma using a 400 GHz frequency gyrotron
Feasibility of collective Thomson scattering (CTS) is examined for LHD high density plasmas. A 400 GHz gyrotron is used as a probe source. Calculations of ray trace through high density plasma and scattering power spectra are carried out. Necessary specifications of the gyrotron for LHD-CTS is estimated.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Feasibility study of collective Thomson scattering in LHD plasma using a 400 GHz frequency gyrotron
Feasibility of collective Thomson scattering (CTS) is examined for LHD high density plasmas. A 400 GHz gyrotron is used as a probe source. Calculations of ray trace through high density plasma and scattering power spectra are carried out. Necessary specifications of the gyrotron for LHD-CTS is estimated.
- Open Access
- 1 January 2008
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 3, S1077
First Demonstration of Rotational Transform Control by Electron Cyclotron Current Drive in Large Helical Device
- 1 January 2008
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 3, S1077
Open AccessFirst Demonstration of Rotational Transform Control by Electron Cyclotron Current Drive in Large Helical Device
- 15 November 2006
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 75 (11) , 114501
Improvement in Plasma Heating at Higher-Density Region Using 106.4 GHz Electron Cyclotron Heating System for Compact Helical System
A 106.4 GHz electron cyclotron heating (ECH) system for compact helical system (CHS) has been newly constructed. Initial experiments to confirm the system's performance showed good controllability of beam direction and polarization for optimized heating. In the beam direction and polarization scan experiments, on-axis beam injection with second-harmonic X-mode polarization resulted in the highest stored energy and central electron temperature. Additional heating becomes possible for the plasmas sustained by neutral beam injection with a density higher than the plasma cutoff density of 3.5×10 19 m -3 for the 53.2 GHz waves of the existing ECH system. Applying the 106.4 GHz heating waves extends the CHS plasma parameter to a high electron temperature of the keV order at a high density up to the second-harmonic X-mode cutoff density of 7×10 19 m -3 .
- 15 November 2006
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 75 (11) , 114501
Improvement in Plasma Heating at Higher-Density Region Using 106.4 GHz Electron Cyclotron Heating System for Compact Helical System
A 106.4 GHz electron cyclotron heating (ECH) system for compact helical system (CHS) has been newly constructed. Initial experiments to confirm the system's performance showed good controllability of beam direction and polarization for optimized heating. In the beam direction and polarization scan experiments, on-axis beam injection with second-harmonic X-mode polarization resulted in the highest stored energy and central electron temperature. Additional heating becomes possible for the plasmas sustained by neutral beam injection with a density higher than the plasma cutoff density of 3.5×10 19 m -3 for the 53.2 GHz waves of the existing ECH system. Applying the 106.4 GHz heating waves extends the CHS plasma parameter to a high electron temperature of the keV order at a high density up to the second-harmonic X-mode cutoff density of 7×10 19 m -3 .