Longxu Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Longxu Jin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Duo Wang
Shanghai Jiao Tong University
5 shared publications - Tianjiao Fu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
4 shared publications - Guoling Bi
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
3 shared publications - Rui Ouyang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Xingxiang Zhang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Guoning Li
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications
Latest Publications
- Open Access
A Region-Monitoring-Type Slitless Imaging Spectrometer
In modern scientific practice, it is necessary to consistently observe predetermined zones, with the expectation of detecting and identifying emerging targets or events inside such areas. This research presents an innovative imaging spectrometer system for the continuous monitoring of specific areas. This study begins by providing detailed information on the features and optical structure of the constructed instrument. This is then followed by simulations using optical design tools. The device has an F-number of 5, a focal length of 100 mm, a field of view of 3 × 7, and a wavelength range spanning from 400 nm to 600 nm. The optical path diagram demonstrates that the system’s dispersion and imaging pictures can be distinguished, hence fulfilling the system’s specifications. Furthermore, the utilization of a Modulation Transfer Function (MTF) graph has substantiated that the image quality indeed satisfies the specified criteria. To evaluate the instrument’s performance in the spectrum observation of fixed regions, a region-monitoring-type slitless imaging spectrometer was built. The equipment has the capability to identify a specific region and rapidly capture the spectra of objects or events that are present inside that region. The spectral data were collected effectively by the implementation of image processing techniques on the captured photos. The correlation coefficient between these data and the reference data was 0.9226, showing that the device successfully measured the target’s spectrum. Therefore, the instrument that was created successfully demonstrated its ability to capture images of the observed areas and collect spectral data from the targets located within those regions.
Open AccessA Region-Monitoring-Type Slitless Imaging Spectrometer
In modern scientific practice, it is necessary to consistently observe predetermined zones, with the expectation of detecting and identifying emerging targets or events inside such areas. This research presents an innovative imaging spectrometer system for the continuous monitoring of specific areas. This study begins by providing detailed information on the features and optical structure of the constructed instrument. This is then followed by simulations using optical design tools. The device has an F-number of 5, a focal length of 100 mm, a field of view of 3 × 7, and a wavelength range spanning from 400 nm to 600 nm. The optical path diagram demonstrates that the system’s dispersion and imaging pictures can be distinguished, hence fulfilling the system’s specifications. Furthermore, the utilization of a Modulation Transfer Function (MTF) graph has substantiated that the image quality indeed satisfies the specified criteria. To evaluate the instrument’s performance in the spectrum observation of fixed regions, a region-monitoring-type slitless imaging spectrometer was built. The equipment has the capability to identify a specific region and rapidly capture the spectra of objects or events that are present inside that region. The spectral data were collected effectively by the implementation of image processing techniques on the captured photos. The correlation coefficient between these data and the reference data was 0.9226, showing that the device successfully measured the target’s spectrum. Therefore, the instrument that was created successfully demonstrated its ability to capture images of the observed areas and collect spectral data from the targets located within those regions.
- Open Access
- 28 April 2024
- Published by MDPI AG in Preprints.org
A Region Monitoring Type Slitless Imaging Spectrometer
In the contemporary world of science, continuous observation of specific fixed regions is required, awaiting the emergence of targets or phenomena within those areas to locate and identify them. Astronomy requires continuous monitoring of stars, swiftly pinpointing occurrences, such as flares, and acquiring their spectral data to aid identification. In military contexts, continuous observation of specific areas is essential for promptly locating enemy movements and obtaining target spectral data for deciphering enemy disguises. Additionally, continuous observation of experimental samples in biochemistry is mandatory to pinpoint localized changes and acquire spectral data from those areas. Hence, this paper develops a novel imaging spectrometer solution to monitor localized regions continuously. Specifically, this paper first elaborates on the developed instrument’s characteristics and optical structure, followed by optical design software simulations. The instrument has an F-number of 5, a focal length of 100mm, and a field of view covering the wavelength range from 400nm to 600nm. The optical path diagram indicates that the system’s dispersion and imaging images can be separated, meeting the system’s requirements. Besides, the Modulation Transfer Function (MTF) graph confirms that the image quality meets the requirements. Furthermore, a region-monitoring type imaging spectrometer was constructed to assess the instrument’s capability for spectral observation of fixed regions. The instrument can detect a fixed area, with the target placed within the detection area. Spectral data were successfully obtained by conducting image processing on the acquired images. The correlation coefficient between this data and reference data was as high as 0.9226, indicating the instrument’s successful measurement of the target’s spectrum. Thus, the developed instrument demonstrated that it can image the observed areas and acquire spectral data from targets within those regions.
- 28 April 2024
- Published by MDPI AG in Preprints.org
Open AccessA Region Monitoring Type Slitless Imaging Spectrometer
In the contemporary world of science, continuous observation of specific fixed regions is required, awaiting the emergence of targets or phenomena within those areas to locate and identify them. Astronomy requires continuous monitoring of stars, swiftly pinpointing occurrences, such as flares, and acquiring their spectral data to aid identification. In military contexts, continuous observation of specific areas is essential for promptly locating enemy movements and obtaining target spectral data for deciphering enemy disguises. Additionally, continuous observation of experimental samples in biochemistry is mandatory to pinpoint localized changes and acquire spectral data from those areas. Hence, this paper develops a novel imaging spectrometer solution to monitor localized regions continuously. Specifically, this paper first elaborates on the developed instrument’s characteristics and optical structure, followed by optical design software simulations. The instrument has an F-number of 5, a focal length of 100mm, and a field of view covering the wavelength range from 400nm to 600nm. The optical path diagram indicates that the system’s dispersion and imaging images can be separated, meeting the system’s requirements. Besides, the Modulation Transfer Function (MTF) graph confirms that the image quality meets the requirements. Furthermore, a region-monitoring type imaging spectrometer was constructed to assess the instrument’s capability for spectral observation of fixed regions. The instrument can detect a fixed area, with the target placed within the detection area. Spectral data were successfully obtained by conducting image processing on the acquired images. The correlation coefficient between this data and reference data was as high as 0.9226, indicating the instrument’s successful measurement of the target’s spectrum. Thus, the developed instrument demonstrated that it can image the observed areas and acquire spectral data from targets within those regions.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Anti-Noise Light Field Depth Estimation Using Inline Occlusion Handling
The light field camera records spatial and angular information of a scene within one shot, which is a unique advantage, especially for depth estimation. Both occlusion and noise make it difficult to estimate the depth of the light field. To address this problem, we propose a depth estimation method using inline occlusion handling, which uses digital refocusing to obtain refocused images and define occlusion types in scenes. An inline occlusion framework is used to construct the correlation cost. In order to remove noise, we use a variety of filtering strategies to optimize the cost. The quantitative results show that, compared with the best performance CAE, our method can reduce the MSE and bad point rate by 40.68% and 25.76%, respectively, in the challenging noise scenes of Old HCI datasets. In New HCI datasets, the reduction is 34.98% and 31.26%, respectively. The qualitative results show that we can preserve various fine structures of the real light field. Therefore, our method has significant advantages in high-noise scenes, which can better deal with the occlusion problem of depth estimation in noisy scenes.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Anti-Noise Light Field Depth Estimation Using Inline Occlusion Handling
The light field camera records spatial and angular information of a scene within one shot, which is a unique advantage, especially for depth estimation. Both occlusion and noise make it difficult to estimate the depth of the light field. To address this problem, we propose a depth estimation method using inline occlusion handling, which uses digital refocusing to obtain refocused images and define occlusion types in scenes. An inline occlusion framework is used to construct the correlation cost. In order to remove noise, we use a variety of filtering strategies to optimize the cost. The quantitative results show that, compared with the best performance CAE, our method can reduce the MSE and bad point rate by 40.68% and 25.76%, respectively, in the challenging noise scenes of Old HCI datasets. In New HCI datasets, the reduction is 34.98% and 31.26%, respectively. The qualitative results show that we can preserve various fine structures of the real light field. Therefore, our method has significant advantages in high-noise scenes, which can better deal with the occlusion problem of depth estimation in noisy scenes.
- Open Access
- 8 January 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (2) , 283
Infrared and Visible Image Fusion Based on Co-Occurrence Analysis Shearlet Transform
This study based on co-occurrence analysis shearlet transform (CAST) effectively combines the latent low rank representation (LatLRR) and the regularization of zero-crossing counting in differences to fuse the heterogeneous images. First, the source images are decomposed by CAST method into base-layer and detail-layer sub-images. Secondly, for the base-layer components with larger-scale intensity variation, the LatLRR, is a valid method to extract the salient information from image sources, and can be applied to generate saliency map to implement the weighted fusion of base-layer images adaptively. Meanwhile, the regularization term of zero crossings in differences, which is a classic method of optimization, is designed as the regularization term to construct the fusion of detail-layer images. By this method, the gradient information concealed in the source images can be extracted as much as possible, then the fusion image owns more abundant edge information. Compared with other state-of-the-art algorithms on publicly available datasets, the quantitative and qualitative analysis of experimental results demonstrate that the proposed method outperformed in enhancing the contrast and achieving close fusion result.
- 8 January 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (2) , 283
Open AccessInfrared and Visible Image Fusion Based on Co-Occurrence Analysis Shearlet Transform
This study based on co-occurrence analysis shearlet transform (CAST) effectively combines the latent low rank representation (LatLRR) and the regularization of zero-crossing counting in differences to fuse the heterogeneous images. First, the source images are decomposed by CAST method into base-layer and detail-layer sub-images. Secondly, for the base-layer components with larger-scale intensity variation, the LatLRR, is a valid method to extract the salient information from image sources, and can be applied to generate saliency map to implement the weighted fusion of base-layer images adaptively. Meanwhile, the regularization term of zero crossings in differences, which is a classic method of optimization, is designed as the regularization term to construct the fusion of detail-layer images. By this method, the gradient information concealed in the source images can be extracted as much as possible, then the fusion image owns more abundant edge information. Compared with other state-of-the-art algorithms on publicly available datasets, the quantitative and qualitative analysis of experimental results demonstrate that the proposed method outperformed in enhancing the contrast and achieving close fusion result.
- Open Access
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11048
Dual-Gratings Imaging Spectrometer
Common dispersive-type spectroscopic instruments include prism-type and grating-type, usually using a single dispersive element. The continuous imaging band is always limited by the dispersion angle. When it is necessary to image two wavebands with an ultra-spectral resolution that are far apart, the imaging is difficult due to the large diffraction angle. To broaden the spectral coverage of the imaging spectrometer, in this paper, we propose a dual-gratings imaging spectrometer with two independently rotating gratings. In this proposed system, two very far apart wavelength bands can be imaged in the adjacent areas by adjusting the angle of the dual gratings. This greatly expands the spectral coverage of the imaging spectrometer. Currently, the only application area considered for this instrument is solar applications. In this article, we present the optical system of the dual-gratings imaging spectrometer, illustrate several advantages of the new structure, and discuss new problems caused by the dual-gratings, which are referred to as overlap between two spectra and double image offset. We deduced the calculation process of the dual grating rotation angle, the relationship between the final acquired image and the slit, the relationship between the angle change between the dual gratings and the double image offset, and the relationship between the MTF upper limit reduction and the spatial frequency. This article also summarizes the shortcomings of this structure and studies the applicable fields under these shortcomings. At last, we simulate a dual-gratings imaging spectrometer system, compare this scheme with two traditional schemes, and conclude that this instrument has certain practical significance.
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11048
Open AccessDual-Gratings Imaging Spectrometer
Common dispersive-type spectroscopic instruments include prism-type and grating-type, usually using a single dispersive element. The continuous imaging band is always limited by the dispersion angle. When it is necessary to image two wavebands with an ultra-spectral resolution that are far apart, the imaging is difficult due to the large diffraction angle. To broaden the spectral coverage of the imaging spectrometer, in this paper, we propose a dual-gratings imaging spectrometer with two independently rotating gratings. In this proposed system, two very far apart wavelength bands can be imaged in the adjacent areas by adjusting the angle of the dual gratings. This greatly expands the spectral coverage of the imaging spectrometer. Currently, the only application area considered for this instrument is solar applications. In this article, we present the optical system of the dual-gratings imaging spectrometer, illustrate several advantages of the new structure, and discuss new problems caused by the dual-gratings, which are referred to as overlap between two spectra and double image offset. We deduced the calculation process of the dual grating rotation angle, the relationship between the final acquired image and the slit, the relationship between the angle change between the dual gratings and the double image offset, and the relationship between the MTF upper limit reduction and the spatial frequency. This article also summarizes the shortcomings of this structure and studies the applicable fields under these shortcomings. At last, we simulate a dual-gratings imaging spectrometer system, compare this scheme with two traditional schemes, and conclude that this instrument has certain practical significance.
- Open Access
- 1 September 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1419
Dehazing with Offset Correction and a Weighted Residual Map
In hazy environments, image quality is degraded by haze and the degraded photos have reduced visibility, making the less vivid and visually attractive. This paper proposes a method for recovering image information from a single hazy image. The dark channel prior algorithm tends to underestimate the transmission of bright areas. To address this problem, an improved dehazing algorithm is proposed in this paper. Assuming that intensity in a dark channel affected by haze produces the same offset, the expected value of the dark channel of a hazy image is used as an approximation of this offset to correct the transmission. However, this correction may neglect scene difference and affect the clarity of the recovered images. Therefore, a weighted residual map is used to enhance contrast and recover more information. Experimental results demonstrate that our algorithm can effectively lessen color oversaturation and restore images with enhanced details. This algorithm provides a more accurate transmission estimation method that can be used with a weighted residual map to eliminate haze and improve contrast.
- 1 September 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1419
Open AccessDehazing with Offset Correction and a Weighted Residual Map
In hazy environments, image quality is degraded by haze and the degraded photos have reduced visibility, making the less vivid and visually attractive. This paper proposes a method for recovering image information from a single hazy image. The dark channel prior algorithm tends to underestimate the transmission of bright areas. To address this problem, an improved dehazing algorithm is proposed in this paper. Assuming that intensity in a dark channel affected by haze produces the same offset, the expected value of the dark channel of a hazy image is used as an approximation of this offset to correct the transmission. However, this correction may neglect scene difference and affect the clarity of the recovered images. Therefore, a weighted residual map is used to enhance contrast and recover more information. Experimental results demonstrate that our algorithm can effectively lessen color oversaturation and restore images with enhanced details. This algorithm provides a more accurate transmission estimation method that can be used with a weighted residual map to eliminate haze and improve contrast.
- Open Access
A High Optical Throughput Spectral Imaging Technique Using Broadband Filters
To address the miniaturization of the spectral imaging system required by a mounted platform and to overcome the low luminous flux caused by current spectroscopic technology, we propose a method for the multichannel measurement of spectra using a broadband filter in this work. The broadband filter is placed in front of a lens, and the spectral absorption characteristics of the broadband filter are used to achieve the modulation of the incident spectrum of the detection target and to establish a mathematical model for the detection of the target. The spectral and spatial information of the target can be obtained by acquiring data using a push-broom method and reconstructing the spectrum using the GCV-based Tikhonov regularization algorithm. In this work, we compare the accuracy of the reconstructed spectra using the least-squares method and the Tikhonov algorithm based on the L-curve. The effect of errors in the spectral modulation function on the accuracy of the reconstructed spectra is analyzed. We also analyze the effect of the number of overdetermined equations on the accuracy of the reconstructed spectra and consider the effect of detector noise on the spectral recovery. A comparison between the known data cubes and our simulation results shows that the spectral image quality based on broadband filter reduction is better, which validates the feasibility of the method. The proposed method of combining broadband filter-based spectroscopy with a panchromatic imaging process for measurement modulation rather than spectroscopic modulation provides a new approach to spectral imaging.
Open AccessA High Optical Throughput Spectral Imaging Technique Using Broadband Filters
To address the miniaturization of the spectral imaging system required by a mounted platform and to overcome the low luminous flux caused by current spectroscopic technology, we propose a method for the multichannel measurement of spectra using a broadband filter in this work. The broadband filter is placed in front of a lens, and the spectral absorption characteristics of the broadband filter are used to achieve the modulation of the incident spectrum of the detection target and to establish a mathematical model for the detection of the target. The spectral and spatial information of the target can be obtained by acquiring data using a push-broom method and reconstructing the spectrum using the GCV-based Tikhonov regularization algorithm. In this work, we compare the accuracy of the reconstructed spectra using the least-squares method and the Tikhonov algorithm based on the L-curve. The effect of errors in the spectral modulation function on the accuracy of the reconstructed spectra is analyzed. We also analyze the effect of the number of overdetermined equations on the accuracy of the reconstructed spectra and consider the effect of detector noise on the spectral recovery. A comparison between the known data cubes and our simulation results shows that the spectral image quality based on broadband filter reduction is better, which validates the feasibility of the method. The proposed method of combining broadband filter-based spectroscopy with a panchromatic imaging process for measurement modulation rather than spectroscopic modulation provides a new approach to spectral imaging.
- Open Access
Long-Distance Sub-Diffraction High-Resolution Imaging Using Sparse Sampling
How to perform imaging beyond the diffraction limit has always been an essential subject for the research of optical systems. One effective way to achieve this purpose is Fourier ptychography, which has been widely used in microscopic imaging. However, microscopic imaging measurement technology cannot be directly extended to imaging macro objects at long distances. In this paper, a reconstruction algorithm is proposed to solve the need for oversampling low-resolution images, and it is successfully applied to macroscopic imaging. Compared with the traditional FP technology, the proposed sub-sampling method can significantly reduce the number of iterations in reconstruction. Experiments prove that the proposed method can reconstruct low-resolution images captured by the camera and achieve high-resolution imaging of long-range macroscopic objects.
Open AccessLong-Distance Sub-Diffraction High-Resolution Imaging Using Sparse Sampling
How to perform imaging beyond the diffraction limit has always been an essential subject for the research of optical systems. One effective way to achieve this purpose is Fourier ptychography, which has been widely used in microscopic imaging. However, microscopic imaging measurement technology cannot be directly extended to imaging macro objects at long distances. In this paper, a reconstruction algorithm is proposed to solve the need for oversampling low-resolution images, and it is successfully applied to macroscopic imaging. Compared with the traditional FP technology, the proposed sub-sampling method can significantly reduce the number of iterations in reconstruction. Experiments prove that the proposed method can reconstruct low-resolution images captured by the camera and achieve high-resolution imaging of long-range macroscopic objects.
- 7 December 2016
- Published by Springer Nature in Transactions of Tianjin University
- Vol. 22 (6) , 596-602
Blind image quality assessment based on wavelet power spectrum in perceptual domain
- 7 December 2016
- Published by Springer Nature in Transactions of Tianjin University
- Vol. 22 (6) , 596-602
Blind image quality assessment based on wavelet power spectrum in perceptual domain