Juan Miguel Piera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juan Miguel Piera has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Antonio López
Foundation for the Promotion of Health and Biomedical Research in the Valencia Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain
1 shared publication - Clara Coscollà
Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21 Avenida Catalunya, 46020 Valencia, Spain
1 shared publication - Esther Fuentes-Ferragud
Foundation for the Promotion of Health and Biomedical Research in the Valencia Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain; Environmental and Public Health Analytical Chemistry, Research Institute for Pesticides and Water, University Jaume I, S/N, Avenida Sos Baynat, 12071, Castellón de la Plana, Spain
1 shared publication - Francisco Xavier Lopez-Labrador
CIBERESP, Instituto de Salud Carlos III , Madrid
1 shared publication - Marisa Camaró
Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020 Valencia, Spain
1 shared publication - María Ibáñez
Environmental and Public Health Analytical Chemistry, Research Institute for Pesticides and Water, University Jaume I, S/N, Avenida Sos Baynat, 12071 Castelló de la Plana, Spain
1 shared publication
Latest Publications
- Open Access
Indoor Air Quality and Bioaerosols in Spanish University Classrooms
A comprehensive study assessed indoor air quality parameters, focusing on relevant air pollutants such as particulate matter (PM10 and PM2.5), gaseous compounds (CO, CO2, formaldehyde, NO2) and volatile/semi-volatile organic chemicals, as well as respiratory viruses (including SARS-CoV-2), fungi and bacteria in Spanish university classrooms. Non-target screening strategies evaluated the presence of organic pollutants inside and outside the classrooms. Saliva samples from teachers and students were collected to explore correlations between respiratory viruses in the air and biological samples. Indoor results revealed the punctual exceedance of recommended guidelines for CO2, formaldehyde (HCHO), volatile organic compounds (TVOCs) and PM in the least naturally ventilated classrooms. Significant differences occurred between the classes, with the least ventilated one showing higher average concentrations of CO2, HCHO, NO2, PM10 and PM2.5. A respiratory virus (rhinovirus/enterovirus) was detected in the medium naturally ventilated classroom, although saliva samples tested negative. Suspect screening tentatively identified 65 substances indoors and over 200 outdoors, with approximately half reporting a high toxicological risk based on the Cramer rules. The study provides a comprehensive overview of indoor air quality, respiratory viruses and organic pollutants in university classrooms, highlighting the variations and potential health risks associated with ventilation differences.
Open AccessIndoor Air Quality and Bioaerosols in Spanish University Classrooms
A comprehensive study assessed indoor air quality parameters, focusing on relevant air pollutants such as particulate matter (PM10 and PM2.5), gaseous compounds (CO, CO2, formaldehyde, NO2) and volatile/semi-volatile organic chemicals, as well as respiratory viruses (including SARS-CoV-2), fungi and bacteria in Spanish university classrooms. Non-target screening strategies evaluated the presence of organic pollutants inside and outside the classrooms. Saliva samples from teachers and students were collected to explore correlations between respiratory viruses in the air and biological samples. Indoor results revealed the punctual exceedance of recommended guidelines for CO2, formaldehyde (HCHO), volatile organic compounds (TVOCs) and PM in the least naturally ventilated classrooms. Significant differences occurred between the classes, with the least ventilated one showing higher average concentrations of CO2, HCHO, NO2, PM10 and PM2.5. A respiratory virus (rhinovirus/enterovirus) was detected in the medium naturally ventilated classroom, although saliva samples tested negative. Suspect screening tentatively identified 65 substances indoors and over 200 outdoors, with approximately half reporting a high toxicological risk based on the Cramer rules. The study provides a comprehensive overview of indoor air quality, respiratory viruses and organic pollutants in university classrooms, highlighting the variations and potential health risks associated with ventilation differences.