Zhichao Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhichao Shen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chenyang Wang
Hunan University of Technology Taishan, Zhuzhou Hunan China
1 shared publication - Ge Yan
State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Hongcai Tang
State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Liyuan Han
State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Qiang Wu
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Qifeng Han
School of Materials Science and Engineering Shanghai Jiao Tong University Shanghai China
1 shared publication
Latest Publications
- Top Cited Papers
- 15 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6688) , 1236-1240
Reinforcing self-assembly of hole transport molecules for stable inverted perovskite solar cells
Power conversion efficiencies (PCEs) of inverted perovskite solar cells (PSCs) have been improved by the use of a self-assembled monolayer (SAM) hole transport layer. Long-term stability of PSCs requires keeping the SAM compact under the perovskite layer during operation. We found that strong polar solvents in the perovskite precursor desorb the SAM if it is anchored on substrates by hydrogen-bonded, rather than covalently bonded, hydroxyl groups. We used atomic-layer deposition to create an indium tin oxide substrate with a fully covalent hydroxyl-covered surface for SAM anchoring, as well as a SAM with a trimethoxysilane group that exhibited strong tridentate anchoring to the substrate. The resulting PSCs achieved PCEs of 24.8 (certified 24.6) and 23.2% with aperture areas of 0.08 and 1.01 square centimeters, respectively. The devices retained 98.9 and 98.2% of the initial PCE after 1000 hours damp-heat test and operation in maximum power point tracking at 85°C for 1200 hours under standard illumination, respectively.
- 15 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6688) , 1236-1240
Top Cited PapersReinforcing self-assembly of hole transport molecules for stable inverted perovskite solar cells
Power conversion efficiencies (PCEs) of inverted perovskite solar cells (PSCs) have been improved by the use of a self-assembled monolayer (SAM) hole transport layer. Long-term stability of PSCs requires keeping the SAM compact under the perovskite layer during operation. We found that strong polar solvents in the perovskite precursor desorb the SAM if it is anchored on substrates by hydrogen-bonded, rather than covalently bonded, hydroxyl groups. We used atomic-layer deposition to create an indium tin oxide substrate with a fully covalent hydroxyl-covered surface for SAM anchoring, as well as a SAM with a trimethoxysilane group that exhibited strong tridentate anchoring to the substrate. The resulting PSCs achieved PCEs of 24.8 (certified 24.6) and 23.2% with aperture areas of 0.08 and 1.01 square centimeters, respectively. The devices retained 98.9 and 98.2% of the initial PCE after 1000 hours damp-heat test and operation in maximum power point tracking at 85°C for 1200 hours under standard illumination, respectively.
- Open Access
- 6 December 2019
- Published by Association for Computing Machinery (ACM)
- p. 1-6
Photovoltaic Inverter Cluster Resonance Suppression Strategy Based on Active Harmonic Conductance Method
In order to suppress the resonance caused by the integration of photovoltaic inverter clusters into the grid, this paper proposes a photovoltaic inverter cluster resonance suppression strategy based on active harmonic conductance method. Firstly, based on the inner loop of the capacitor current under the PI controller and the double closed loop control of the outer loop of the grid current, the resonance suppression effect of the single inverter under the double closed loop control is analyzed. Then, while keeping the control system unchanged, the active filter conductance is added to the photovoltaic grid-connected system for multiple inverter resonance problems, which not only effectively suppresses the inverter low-frequency harmonic current from flowing into the grid-side system, but also improves The inverter is resistant to disturbances, thereby suppressing resonance problems caused by inverter clusters. Finally, the photovoltaic inverter cluster resonance energy is effectively suppressed by Matlab/Simulink software.
- 6 December 2019
- Published by Association for Computing Machinery (ACM)
- p. 1-6
Open AccessPhotovoltaic Inverter Cluster Resonance Suppression Strategy Based on Active Harmonic Conductance Method
In order to suppress the resonance caused by the integration of photovoltaic inverter clusters into the grid, this paper proposes a photovoltaic inverter cluster resonance suppression strategy based on active harmonic conductance method. Firstly, based on the inner loop of the capacitor current under the PI controller and the double closed loop control of the outer loop of the grid current, the resonance suppression effect of the single inverter under the double closed loop control is analyzed. Then, while keeping the control system unchanged, the active filter conductance is added to the photovoltaic grid-connected system for multiple inverter resonance problems, which not only effectively suppresses the inverter low-frequency harmonic current from flowing into the grid-side system, but also improves The inverter is resistant to disturbances, thereby suppressing resonance problems caused by inverter clusters. Finally, the photovoltaic inverter cluster resonance energy is effectively suppressed by Matlab/Simulink software.