Junior Francois Sanchez-Bautista
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junior Francois Sanchez-Bautista has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Lennin Roswell Rodriguez Saavedra
Universidad Nacional de Trujillo | Trujillo | Perú
2 shared publications - Luis Alberto Chavez Abanto
Universidad Nacional de Trujillo
2 shared publications - Segundo Francisco Saavedra Suarez
Universidad Nacional de Trujillo
2 shared publications - Leandro Emanuel Sandoval Guerra
Universidad Nacional de Trujillo | Trujillo | Perú
1 shared publication - Miriam Elizabeth Gutierrez Ramos
Universidad Nacional de Trujillo | Trujillo | Perú
1 shared publication - Olga Elizabeth Caballero Aquiño
Universidad Nacional de Trujillo | Trujillo | Perú
1 shared publication
Latest Publications
- 1 September 2024
- Published by Garval Editorial Ltda. in Journal of Pharmacy & Pharmacognosy Research
- Vol. 12 (5) , 814-821
Dissolution kinetics of propranolol hydrochloride 40 mg tablets under biowaiver conditions
Context: Ensuring the quality of a generic drug is essential for its commercialization. Propranolol hydrochloride is a drug in great demand on the market as it is widely used as an antihypertensive, antianginal, antiarrhythmic, and for the treatment of migraine, requiring a complete evaluation to determine equivalence. Aims: To evaluate the dissolution biopharmaceutical characteristic in multisource products marketed in the Peruvian market, taking Inderal® as a reference product. Methods: In vitro conditions are simulated using the USP apparatus II at 50 rpm and 900 mL of the dissolution media pH 1.2, 4.5, and 6.8 at 37°C. The dependent mathematical models were characterized by the Akaike information criterion, and the similarity was evaluated using the independent parameters (MDT, DE, and the similarity factor f2). Results: The average dissolution percentages demonstrate a difference between the multisource and the innovator in the three-dissolution media. The model that best characterizes the dissolution kinetics in all products is that of Hixson–Crowell. A significant difference was obtained in the MDT and DE between the innovative and multisource products and in the three-dissolution media. The similarity factor was not within the acceptable range for multisource products in the three-dissolution media. Conclusions: The 40 mg propranolol hydrochloride tablets included in the study are not equivalent in vitro to the innovative product and, therefore, are not interchangeable.
- 1 September 2024
- Published by Garval Editorial Ltda. in Journal of Pharmacy & Pharmacognosy Research
- Vol. 12 (5) , 814-821
Dissolution kinetics of propranolol hydrochloride 40 mg tablets under biowaiver conditions
Context: Ensuring the quality of a generic drug is essential for its commercialization. Propranolol hydrochloride is a drug in great demand on the market as it is widely used as an antihypertensive, antianginal, antiarrhythmic, and for the treatment of migraine, requiring a complete evaluation to determine equivalence. Aims: To evaluate the dissolution biopharmaceutical characteristic in multisource products marketed in the Peruvian market, taking Inderal® as a reference product. Methods: In vitro conditions are simulated using the USP apparatus II at 50 rpm and 900 mL of the dissolution media pH 1.2, 4.5, and 6.8 at 37°C. The dependent mathematical models were characterized by the Akaike information criterion, and the similarity was evaluated using the independent parameters (MDT, DE, and the similarity factor f2). Results: The average dissolution percentages demonstrate a difference between the multisource and the innovator in the three-dissolution media. The model that best characterizes the dissolution kinetics in all products is that of Hixson–Crowell. A significant difference was obtained in the MDT and DE between the innovative and multisource products and in the three-dissolution media. The similarity factor was not within the acceptable range for multisource products in the three-dissolution media. Conclusions: The 40 mg propranolol hydrochloride tablets included in the study are not equivalent in vitro to the innovative product and, therefore, are not interchangeable.
- Open Access
- 20 March 2024
- Published by Editorial de la Universidad de Granada in Ars Pharmaceutica (Internet)
- Vol. 65 (2) , 98-106
Efecto de las metodologías analíticas en la cuantificación de bitartrato de epinefrina según la USP-43 y USP-44
Introduction: Epinephrine bitartrate, also known as epinephrine, is an important pharmaceutical ingredient in the treatment of various diseases, but its accurate measurement is essential to ensure the safety of the drug. The United States Pharmacopeia (USP) sets the standards for its analysis, but the choice of method affects the precision of the measurements. This study investigates how different methods affect the measurements of epinephrine bitartrate based on USP-43 and USP-44, which have significant implications for drug quality and regulation in the field. Method: The volumetric method and chromatographic method were chosen for comparison. High-purity epinephrine bitartrate samples that met USP-43 and USP-44 standards were used. Results: The results obtained by both methods are compared with and evaluated according to the specification limits defined by USP-43 and USP-44. The values obtained for some parameters, such as the concentration and purity of epinephrine tartrate, vary considerably between the different analytical methods. Conclusions: This study highlights the importance of carefully selecting analytical methods when evaluating epinephrine tartrate according to USP-43 and USP-44 guidelines. The choice of technology affects the results and, therefore, the quality and safety of the pharmaceutical products containing this substance. It is recommended to validate the method in each laboratory and compare the results with USP standards. ntroducción: El bitartrato de epinefrina, también conocido como epinefrina, es un ingrediente farmacéutico importante en el tratamiento de diversas enfermedades, pero su medición precisa es esencial para garantizar la seguridad del medicamento. La Farmacopea de los Estados Unidos (USP) establece los estándares para su análisis, pero la elección del método afecta la precisión de las mediciones. Este estudio investiga cómo los diferentes métodos afectan la medición del bitartrato de epinefrina según las versiones USP-43 y USP-44, que tienen implicaciones significativas para la calidad y la regulación de los medicamentos en el campo. Método: Se eligieron el método volumétrico y el método cromatográfico para comparación. Se utilizaron muestras de epinefrina bitartrato de alta pureza que cumplían con los estándares de la USP-43 y USP-44. Resultados: Los resultados obtenidos por ambos métodos se comparan entre sí y se evalúan según los límites de especificación definidos por USP-43 y USP-44. Los valores obtenidos para algunos parámetros, como la concentración y la pureza del bitartrato de epinefrina, varían considerablemente entre los distintos métodos analíticos. Conclusiones: Este estudio destaca la importancia de una cuidadosa selección del método analítico al evaluar el bitartrato de epinefrina según las directrices USP-43 y USP-44. La elección de la tecnología afecta a los resultados y, por tanto, a la calidad y seguridad de los productos farmacéuticos que contienen esta sustancia. Se recomienda validar el método en cada laboratorio y comparar los resultados con los estándares USP.
- 20 March 2024
- Published by Editorial de la Universidad de Granada in Ars Pharmaceutica (Internet)
- Vol. 65 (2) , 98-106
Open AccessEfecto de las metodologías analíticas en la cuantificación de bitartrato de epinefrina según la USP-43 y USP-44
Introduction: Epinephrine bitartrate, also known as epinephrine, is an important pharmaceutical ingredient in the treatment of various diseases, but its accurate measurement is essential to ensure the safety of the drug. The United States Pharmacopeia (USP) sets the standards for its analysis, but the choice of method affects the precision of the measurements. This study investigates how different methods affect the measurements of epinephrine bitartrate based on USP-43 and USP-44, which have significant implications for drug quality and regulation in the field. Method: The volumetric method and chromatographic method were chosen for comparison. High-purity epinephrine bitartrate samples that met USP-43 and USP-44 standards were used. Results: The results obtained by both methods are compared with and evaluated according to the specification limits defined by USP-43 and USP-44. The values obtained for some parameters, such as the concentration and purity of epinephrine tartrate, vary considerably between the different analytical methods. Conclusions: This study highlights the importance of carefully selecting analytical methods when evaluating epinephrine tartrate according to USP-43 and USP-44 guidelines. The choice of technology affects the results and, therefore, the quality and safety of the pharmaceutical products containing this substance. It is recommended to validate the method in each laboratory and compare the results with USP standards. ntroducción: El bitartrato de epinefrina, también conocido como epinefrina, es un ingrediente farmacéutico importante en el tratamiento de diversas enfermedades, pero su medición precisa es esencial para garantizar la seguridad del medicamento. La Farmacopea de los Estados Unidos (USP) establece los estándares para su análisis, pero la elección del método afecta la precisión de las mediciones. Este estudio investiga cómo los diferentes métodos afectan la medición del bitartrato de epinefrina según las versiones USP-43 y USP-44, que tienen implicaciones significativas para la calidad y la regulación de los medicamentos en el campo. Método: Se eligieron el método volumétrico y el método cromatográfico para comparación. Se utilizaron muestras de epinefrina bitartrato de alta pureza que cumplían con los estándares de la USP-43 y USP-44. Resultados: Los resultados obtenidos por ambos métodos se comparan entre sí y se evalúan según los límites de especificación definidos por USP-43 y USP-44. Los valores obtenidos para algunos parámetros, como la concentración y la pureza del bitartrato de epinefrina, varían considerablemente entre los distintos métodos analíticos. Conclusiones: Este estudio destaca la importancia de una cuidadosa selección del método analítico al evaluar el bitartrato de epinefrina según las directrices USP-43 y USP-44. La elección de la tecnología afecta a los resultados y, por tanto, a la calidad y seguridad de los productos farmacéuticos que contienen esta sustancia. Se recomienda validar el método en cada laboratorio y comparar los resultados con los estándares USP.