Clobite Bouka Biona
Clobite Bouka Biona has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
A. Minga
Institut National de Recherche en Sciences Exactes et Naturelles (IRSEN), Brazzaville, Congo
2 shared publications- Armel Ibala Zamba
Institut National de Recherche en Sciences Exactes et Naturelles (IRSEN), Brazzaville, Congo
2 shared publications B. D. Loubelo Madiela
Institut National de Recherche en Sciences Exactes et Naturelles (IRSEN), Brazzaville, Congo
2 shared publications- F. Moussoki
Institut National de Recherche en Sciences Exactes et Naturelles (IRSEN), Brazzaville, Congo
2 shared publications - Guy Blanchard Dallou
Physic, Faculty of Science and Technology, Marien Ngouabi University, BP 69 Brazzaville, Congo
2 shared publications - Philippe Ondo Meye
Direction Générale de la Radioprotection et de la Sûreté Nucléaire, ministère de l’Energie et des Ressources Hydrauliques, Gabon., Libreville, Gabon, Gabon
2 shared publications
Latest Publications
- Open Access
Solar Energy Potential for the Sustainable Energy Transition in the Republic of the Congo
The Republic of the Congo is facing significant challenges in terms of access to electricity, particularly in the extensive rural and remote areas. A reliable assessment of solar resources and photovoltaic (PV) potential is needed to support the development of decentralized sustainable energy solutions. This study evaluates the potential for photovoltaic electricity production in Brazzaville based on in situ radiation measurements. The potential was extended across the country using satellite data from SolarGIS through calibration, although this requires further validation of satellite data in certain transition zones, ranging from the southern savannas to the dense equatorial forests in the north of the country. Measurements taken over a year at the Cité Scientifique de Brazzaville using LP02 and CS300 pyranometers were compared to SolarGIS estimates using statistical performance indicators. There is better agreement between these sensors, with R2 = 0.80 and an RMSE = 0.47 kWh/m2/day. However, we observed between the SolarGIS data and the LP02 measurements an R2 = 0.91 and an RMSE = 0.17 kWh/m2/day (3.8%), whereas with the CS300 we obtained R2 = 0.77 and RMSE = 0.59 kWh/m2/day (14%), which shows a better performance of LP02 compared with CS300. In terms of photovoltaic energy production, the average photovoltaic solar yield was estimated at 3.9 kWh/kWp/day for the LP02 and 3.5 kWh/kWp/day for the CS300, with an annual yield of approximately 1424 kWh/kWp for the LP02, corresponding to estimated discrepancies in photovoltaic production of 0.14 kWh/kWp/day. Based on this, we estimated that a 50 kWp photovoltaic solar system would produce approximately an annual power of 71,200 kWh, which would supply 285 households for a village. These results confirm both the significant potential of solar photovoltaics for decentralized rural electrification and the usefulness of calibrated SolarGIS data for assessing solar resources in areas with limited site-level data. These efforts align well with the planning and investment needs deployed by the Republic of Congo to ensure sustainable electrification of rural areas (PND 2022–2026; National Energy Pact (NEP) and Mission 300).
Open AccessSolar Energy Potential for the Sustainable Energy Transition in the Republic of the Congo
The Republic of the Congo is facing significant challenges in terms of access to electricity, particularly in the extensive rural and remote areas. A reliable assessment of solar resources and photovoltaic (PV) potential is needed to support the development of decentralized sustainable energy solutions. This study evaluates the potential for photovoltaic electricity production in Brazzaville based on in situ radiation measurements. The potential was extended across the country using satellite data from SolarGIS through calibration, although this requires further validation of satellite data in certain transition zones, ranging from the southern savannas to the dense equatorial forests in the north of the country. Measurements taken over a year at the Cité Scientifique de Brazzaville using LP02 and CS300 pyranometers were compared to SolarGIS estimates using statistical performance indicators. There is better agreement between these sensors, with R2 = 0.80 and an RMSE = 0.47 kWh/m2/day. However, we observed between the SolarGIS data and the LP02 measurements an R2 = 0.91 and an RMSE = 0.17 kWh/m2/day (3.8%), whereas with the CS300 we obtained R2 = 0.77 and RMSE = 0.59 kWh/m2/day (14%), which shows a better performance of LP02 compared with CS300. In terms of photovoltaic energy production, the average photovoltaic solar yield was estimated at 3.9 kWh/kWp/day for the LP02 and 3.5 kWh/kWp/day for the CS300, with an annual yield of approximately 1424 kWh/kWp for the LP02, corresponding to estimated discrepancies in photovoltaic production of 0.14 kWh/kWp/day. Based on this, we estimated that a 50 kWp photovoltaic solar system would produce approximately an annual power of 71,200 kWh, which would supply 285 households for a village. These results confirm both the significant potential of solar photovoltaics for decentralized rural electrification and the usefulness of calibrated SolarGIS data for assessing solar resources in areas with limited site-level data. These efforts align well with the planning and investment needs deployed by the Republic of Congo to ensure sustainable electrification of rural areas (PND 2022–2026; National Energy Pact (NEP) and Mission 300).
- Open Access
- 1 June 2024
- Published by Springer Nature in Theoretical and Applied Climatology
- Vol. 155 (6) , 5051-5052
Correction to: Identification of extreme rainfall events in the Republic of Congo from analysis of meteorological tendencies
- 1 June 2024
- Published by Springer Nature in Theoretical and Applied Climatology
- Vol. 155 (6) , 5051-5052
Open AccessCorrection to: Identification of extreme rainfall events in the Republic of Congo from analysis of meteorological tendencies
- Open Access
- 18 May 2024
- Published by Pandawa Institute in Journal of Multidisciplinary Applied Natural Science
- Vol. 4 (2) , 262-272
Establishment of Typical Dose Reference Level (DRL) Values for Adult Patients Undergoing Computed Tomography in Three Hospitals in Brazzaville, Congo Republic
The present study aimed at to establish typical dose reference level (DRL) values for adult patients undergoing computed tomography (CT) examinations in three hospitals in Brazzaville, Congo Republic. The examinations considered were head, chest, abdomen-pelvis, chest-abdomen-pelvis and lumbar spine CT scans. For each examination, the median of the distribution for the volume CT dose index (CTDIvol) and dose-length product (DLP) were determined. The median values were considered as the typical DRL values. Hypothesis testing was also carried out to statistically compare the mean values obtained for each participating CT facility. In the case of head scan, the typical values proposed in the present study in terms of CTDIvol and DLP were 15–48% and 28–60% lower than the DRL values reported in the literature, respectively. In the case of lumbar spine, the typical value determined in this study in terms of DLP was 48–70% greater than the DRL values provided in the literature. The typical values proposed for chest, abdomen-pelvis and chest-abdomen-pelvis were within the DRL values reported in the literature. It is possible that the adoption of the typical values proposed in the present study will help in reducing the dose received by adult patients undergoing CT examination in Congo Republic.
- 18 May 2024
- Published by Pandawa Institute in Journal of Multidisciplinary Applied Natural Science
- Vol. 4 (2) , 262-272
Open AccessEstablishment of Typical Dose Reference Level (DRL) Values for Adult Patients Undergoing Computed Tomography in Three Hospitals in Brazzaville, Congo Republic
The present study aimed at to establish typical dose reference level (DRL) values for adult patients undergoing computed tomography (CT) examinations in three hospitals in Brazzaville, Congo Republic. The examinations considered were head, chest, abdomen-pelvis, chest-abdomen-pelvis and lumbar spine CT scans. For each examination, the median of the distribution for the volume CT dose index (CTDIvol) and dose-length product (DLP) were determined. The median values were considered as the typical DRL values. Hypothesis testing was also carried out to statistically compare the mean values obtained for each participating CT facility. In the case of head scan, the typical values proposed in the present study in terms of CTDIvol and DLP were 15–48% and 28–60% lower than the DRL values reported in the literature, respectively. In the case of lumbar spine, the typical value determined in this study in terms of DLP was 48–70% greater than the DRL values provided in the literature. The typical values proposed for chest, abdomen-pelvis and chest-abdomen-pelvis were within the DRL values reported in the literature. It is possible that the adoption of the typical values proposed in the present study will help in reducing the dose received by adult patients undergoing CT examination in Congo Republic.
- 20 March 2024
- Published by Springer Nature in Theoretical and Applied Climatology
- Vol. 155 (6) , 5033-5049
Identification of extreme rainfall events in the Republic of Congo from analysis of meteorological tendencies
- 20 March 2024
- Published by Springer Nature in Theoretical and Applied Climatology
- Vol. 155 (6) , 5033-5049
Identification of extreme rainfall events in the Republic of Congo from analysis of meteorological tendencies
- 15 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 437-447
Simultaneous measurements of radon, thoron and thoron progeny and induced cancer risk assessment in Djeno, Pointe-Noire, Republic of Congo
In this study, the activity concentrations of radon (222Rn), thoron (220Rn) and thoron progeny were measured simultaneously in Djeno (Pointe-Noire, Republic of Congo) using RADUET detectors to evaluate the air quality and the radiological risks due to the inhalation of these radionuclides. Activity concentrations of radon progeny were calculated from those of radon. Indoor radon, thoron and progenies followed a lognormal distribution ranging between 20 and 40, 6 and 62, 8 and 17.6 and 0.4 and 19.6 Bq m−3 for radon, thoron, radon progeny and thoron progeny, respectively. Mean values for radon were lower than the worldwide values estimated by the United Nation Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), which are 40 Bq m−3 (arithmetic mean) and 45 Bq m−3 (geometric mean). Radon concentrations in the dwellings under study were below the World Health Organization and the International Commission on Radiological Protection recommended reference levels, which are, respectively, 100 and 300 Bq m−3. The mean concentration of thoron was twice the world average value of 10 Bq m−3 estimated by UNSCEAR. Thoron progeny mean concentration was sharply greater than the typical value (0.3 Bq m−3) for indoor atmosphere provided by UNSCEAR. Annual effective dose ranges were 0.40–0.87 mSv (arithmetic mean, 0.57 ± 0.11 mSv) for radon and 0.10–4.14 mSv (arithmetic mean, 0.55 ± 0.77 mSv) for thoron. The mean value for radon was lower than the value (1.15 mSv) estimated by UNSCEAR, while the mean value for thoron was five times higher than the UNSCEAR value (0.10 mSv). The study showed that the use of the typical equilibrium factor value given by UNSCEAR to compute effective dose led to an error above 80%. Finally, the results of this study showed that the excess relative risk of radon-induced cancer was low, below 2% for the population under 55 y. The results presented in the present study prove that the population of Djeno is exposed to a relatively low potential risk of radon- and thoron-induced cancer.
- 15 January 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (5) , 437-447
Simultaneous measurements of radon, thoron and thoron progeny and induced cancer risk assessment in Djeno, Pointe-Noire, Republic of Congo
In this study, the activity concentrations of radon (222Rn), thoron (220Rn) and thoron progeny were measured simultaneously in Djeno (Pointe-Noire, Republic of Congo) using RADUET detectors to evaluate the air quality and the radiological risks due to the inhalation of these radionuclides. Activity concentrations of radon progeny were calculated from those of radon. Indoor radon, thoron and progenies followed a lognormal distribution ranging between 20 and 40, 6 and 62, 8 and 17.6 and 0.4 and 19.6 Bq m−3 for radon, thoron, radon progeny and thoron progeny, respectively. Mean values for radon were lower than the worldwide values estimated by the United Nation Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), which are 40 Bq m−3 (arithmetic mean) and 45 Bq m−3 (geometric mean). Radon concentrations in the dwellings under study were below the World Health Organization and the International Commission on Radiological Protection recommended reference levels, which are, respectively, 100 and 300 Bq m−3. The mean concentration of thoron was twice the world average value of 10 Bq m−3 estimated by UNSCEAR. Thoron progeny mean concentration was sharply greater than the typical value (0.3 Bq m−3) for indoor atmosphere provided by UNSCEAR. Annual effective dose ranges were 0.40–0.87 mSv (arithmetic mean, 0.57 ± 0.11 mSv) for radon and 0.10–4.14 mSv (arithmetic mean, 0.55 ± 0.77 mSv) for thoron. The mean value for radon was lower than the value (1.15 mSv) estimated by UNSCEAR, while the mean value for thoron was five times higher than the UNSCEAR value (0.10 mSv). The study showed that the use of the typical equilibrium factor value given by UNSCEAR to compute effective dose led to an error above 80%. Finally, the results of this study showed that the excess relative risk of radon-induced cancer was low, below 2% for the population under 55 y. The results presented in the present study prove that the population of Djeno is exposed to a relatively low potential risk of radon- and thoron-induced cancer.