Heba Mesbah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Heba Mesbah has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Zubaid Rafique
Emergency Medicine Department, Baylor College of Medicine, Houston, Texas
3 shared publicationsNidal Moukaddam
Psychiatry, and Behavioral Sciences, Baylor College of Medicine, Houston, Texas
2 shared publicationsWilliam Frank Peacock
Emergency Medicine Department, Baylor College of Medicine, Houston, Texas
2 shared publicationsAnita Rohra
Department of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA
1 shared publication- Bryan Hoang
McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX 77004, USA
1 shared publication - Dick C. Kuo
Henry JN Taub Department of Emergency Medicine, Baylor College of Medicine, Houston, TX 77030, USA
1 shared publication
Latest Publications
- 22 February 2025
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 75, 232-240
Shah's Score After a Decade: Is It Still a Reliable Tool for Psychiatric Screening in the Emergency Department?
- 22 February 2025
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 75, 232-240
Shah's Score After a Decade: Is It Still a Reliable Tool for Psychiatric Screening in the Emergency Department?
- 13 March 2024
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 80, 44-50
Predicting aggressive behavior in psychiatric patients in emergency department: A systematic literature review
- 13 March 2024
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 80, 44-50
Predicting aggressive behavior in psychiatric patients in emergency department: A systematic literature review
- Open Access
- 2 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (23) , 16140
Hyperkalemia and Electrocardiogram Manifestations in End-Stage Renal Disease
Hyperkalemia is one of the more common acute life-threatening metabolic emergencies. The aim of our study is to determine the correlation and accuracy of abnormal ECG parameters as a function of serum potassium concentration in the end-stage renal disease (ESRD) population. We performed a retrospective chart review of emergency department patients presenting with ESRD and receiving emergent hemodialysis treatment. A total of 96 patients, each with five independent ED visits, provided 480 sets of ECGs and electrolytes. Of these, four ECGs were excluded for inability to interpret, leaving a total of 476 patient encounters that met all inclusion criteria. Linear regression analysis on the limited data set for serum potassium versus T/R in V2, V3, and V4, PR, and QRS found weak correlations (r2 = 0.02 to 0.12) with statistical significance <0.05 level for T/R in V2, V3, and V4. In summary, we found that a QRS duration of 120 ms or greater is most predictive of hyperkalemia in the ESRD population. On the other hand, T/R ratio, PR interval and QRS duration have poor correlations with serum potassium and are not predictive of hyperkalemia in patients with ESRD.
- 2 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (23) , 16140
Open AccessHyperkalemia and Electrocardiogram Manifestations in End-Stage Renal Disease
Hyperkalemia is one of the more common acute life-threatening metabolic emergencies. The aim of our study is to determine the correlation and accuracy of abnormal ECG parameters as a function of serum potassium concentration in the end-stage renal disease (ESRD) population. We performed a retrospective chart review of emergency department patients presenting with ESRD and receiving emergent hemodialysis treatment. A total of 96 patients, each with five independent ED visits, provided 480 sets of ECGs and electrolytes. Of these, four ECGs were excluded for inability to interpret, leaving a total of 476 patient encounters that met all inclusion criteria. Linear regression analysis on the limited data set for serum potassium versus T/R in V2, V3, and V4, PR, and QRS found weak correlations (r2 = 0.02 to 0.12) with statistical significance <0.05 level for T/R in V2, V3, and V4. In summary, we found that a QRS duration of 120 ms or greater is most predictive of hyperkalemia in the ESRD population. On the other hand, T/R ratio, PR interval and QRS duration have poor correlations with serum potassium and are not predictive of hyperkalemia in patients with ESRD.
- Open Access
- 1 September 2019
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 6 (3) , 226-234
Diagnostic accuracy and temporal impact of ultrasound in patients with dyspnea admitted to the emergency department
Few studies have prospectively evaluated the diagnostic accuracy and temporal impact of ultrasound in the emergency department (ED) in a randomized manner. In this study, we aimed to perform a randomized, standard therapy controlled evaluation of the diagnostic accuracy and temporal impact of a standardized ultrasound strategy, versus standard care, in patients presenting to the ED with acute dyspnea. The patients underwent a standardized ultrasound examination that was blinded to the team caring for the patient. Ultrasound results remained blinded in patients randomized to the treating team but were unblinded in the interventional cohort. Scans were performed by trained emergency physicians. The gold standard diagnosis (GSDx) was determined by two physicians blinded to the ultrasound results. The same two physicians reviewed all data >30 days after the index visit. Fifty-nine randomized patients were enrolled. The mean±standard deviation age was 54.4±11 years, and 37 (62%) were male. The most common GSDx was acute heart failure with reduced ejection fraction in 13 (28.3%) patients and airway diseases such as acute exacerbation of asthma or chronic obstructive pulmonary disease in 10 (21.7%). ED diagnostic accuracy, as compared to the GSDx, was 76% in the ultrasound cohort and 79% in the standard care cohort (P=0.796). Compared with the standard care cohort, the final diagnosis was obtained much faster in the ultrasound cohort (mean±standard deviation: 12±3.2 minutes vs. 270 minutes, P<0.001). A standardized ultrasound approach is equally accurate, but enables faster ED diagnosis of acute dyspnea than standard care.
- 1 September 2019
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 6 (3) , 226-234
Open AccessDiagnostic accuracy and temporal impact of ultrasound in patients with dyspnea admitted to the emergency department
Few studies have prospectively evaluated the diagnostic accuracy and temporal impact of ultrasound in the emergency department (ED) in a randomized manner. In this study, we aimed to perform a randomized, standard therapy controlled evaluation of the diagnostic accuracy and temporal impact of a standardized ultrasound strategy, versus standard care, in patients presenting to the ED with acute dyspnea. The patients underwent a standardized ultrasound examination that was blinded to the team caring for the patient. Ultrasound results remained blinded in patients randomized to the treating team but were unblinded in the interventional cohort. Scans were performed by trained emergency physicians. The gold standard diagnosis (GSDx) was determined by two physicians blinded to the ultrasound results. The same two physicians reviewed all data >30 days after the index visit. Fifty-nine randomized patients were enrolled. The mean±standard deviation age was 54.4±11 years, and 37 (62%) were male. The most common GSDx was acute heart failure with reduced ejection fraction in 13 (28.3%) patients and airway diseases such as acute exacerbation of asthma or chronic obstructive pulmonary disease in 10 (21.7%). ED diagnostic accuracy, as compared to the GSDx, was 76% in the ultrasound cohort and 79% in the standard care cohort (P=0.796). Compared with the standard care cohort, the final diagnosis was obtained much faster in the ultrasound cohort (mean±standard deviation: 12±3.2 minutes vs. 270 minutes, P<0.001). A standardized ultrasound approach is equally accurate, but enables faster ED diagnosis of acute dyspnea than standard care.