Zhi-Xin Meng
Research Subjects
Zhi-Xin Meng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yan-Ying Feng
Tsinghua University
3 shared publications - Sheng-Zhe Wang
Tsinghua University
2 shared publications Yi-Cheng Deng
Beijing Institute of Aerospace Control Devices
2 shared publications- Hongbo Xue
State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Ke Shen
Tsinghua University
1 shared publication - Pei-Qiang Yan
State Key Laboratory of Precision Measurement Technology and Instruments, Beijing, China
1 shared publication
Latest Publications
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3) , 034003
Closed-loop dual-channel atomic beam interferometry beyond the half-fringe limit
Atomic interferometers offer extraordinary inertial sensitivity, yet their intrinsically periodic response has long prevented continuous operation over a wide dynamic range. The authors demonstrate a dual-channel closed-loop atomic beam interferometer, enabling simultaneous quantum feedback for rotation and acceleration. By converting periodic matter-wave interference into continuously tracked control parameters, the scheme overcomes the conventional half-fringe limitation while preserving precision. This advance brings practical quantum inertial navigation a significant step closer.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3) , 034003
Closed-loop dual-channel atomic beam interferometry beyond the half-fringe limit
Atomic interferometers offer extraordinary inertial sensitivity, yet their intrinsically periodic response has long prevented continuous operation over a wide dynamic range. The authors demonstrate a dual-channel closed-loop atomic beam interferometer, enabling simultaneous quantum feedback for rotation and acceleration. By converting periodic matter-wave interference into continuously tracked control parameters, the scheme overcomes the conventional half-fringe limitation while preserving precision. This advance brings practical quantum inertial navigation a significant step closer.
- 14 April 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (4)
Compact continuous cold atomic beam from a single cell with three-dimensional cooling and ultralow light shift
- 14 April 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (4)
Compact continuous cold atomic beam from a single cell with three-dimensional cooling and ultralow light shift
- 22 March 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (3) , 034050
Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams
We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area ). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.- 22 March 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (3) , 034050
Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams
We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area ). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.