OMOlivier Mayeur

Olivier Mayeur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olivier Mayeur has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Towards minimally invasive prosthetic surgery of the temporomandibular joint: design and integrated CAD–FEM preclinical approach on the mini-pig

    by Nicolas Bethune, Lilian Baugnon, Jean-François Guignardat, Olivier Mayeur, Romain Nicot

    1. The temporomandibular joint (TMJ) is a highly specialized anatomical structure subjected to complex and repetitive mechanical loading during essential orofacial functions such as mastication, ph...

  • Open Access

    Uncertainty quantification and global sensitivity analysis of a patient-specific mandibular finite element model using Latin hypercube sampling and sparse polynomial chaos expansion

    by Lilian Baugnon, Romain Nicot, Nicolas Bethune, Pauline Lecomte-Grosbras, Jean-François Witz, Jean-Baptiste Colliat, Olivier Mayeur

    Uncertainty quantification and global sensitivity analysis of a patient-specific mandibular finite element model using Latin hypercube sampling and sparse polynomial chaos expansion, Baugnon, Lilian, Nicot, Romain, Bethune, Nicolas, Lecomte-Grosbras, Pauline, Witz, Jean-François, Colliat, Jean-Baptiste, Mayeur, Olivier Uncertainty quantification and global sensitivity analysis of a patient-specific mandibular finite element model using Latin hypercube sampling and sparse polynomial chaos expansion, Baugnon, Lilian, Nicot, Romain, Bethune, Nicolas, Lecomte-Grosbras, Pauline, Witz, Jean-François, Colliat, Jean-Baptiste, Mayeur, Olivier

  • Integrated Workflow Finite Element Modeling of the Temporomandibular Joint: Toward a Methodical and Reproducible Approach

    by Lilian Baugnon, Romain Nicot, Nicolas Bethune, Pauline Lecomte-Grosbras, Jean-François Witz, Olivier Mayeur

    This study presents a patient-specific parametric model of the temporomandibular joint, designed to be semi-automated, and reproducible for multiple patients. The numerical model is used to evaluate mandibular stress distribution under different interaction and loading conditions. The main contribution is to demonstrate the feasibility of an integrated, fast, and streamlined workflow for generating accurate biomechanical models tailored to each patient. The proposed method, which relies on standard clinical images complemented by artificial intelligence-assisted segmentation of bone and muscles, enables the integration of patient-specific anatomical features and mechanical variability. A finite element model of the skull, mandible, teeth, and articular disks was constructed from calibrated computed tomography data. Material properties were automatically assigned using Hounsfield units, distinguishing between cortical bone, cancellous bone, and dental tissue. Sensitivity of key modeling parameters (mesh density, material, friction coefficients, muscle force vectors) was evaluated using abaqus/standard. Hounsfield-units-driven material assignment provides a Young modulus distribution aligned with the literature, while maintaining patient specificity. Artificial intelligence-based muscle reconstruction reveals that stress fields stabilize with increased directional vector refinement, reinforcing biomechanical accuracy and confirming the necessity of multivector muscle loading. This patient-specific parametric model accurately reproduces the distribution of mandibular stresses and offers a promising tool for surgical planning, pathology simulation, and the evaluation of personalized treatment strategies.


  • Open Access

    The Development of a Forceps-Adaptable Pressure Device for Instrumental Delivery: A Proof-of-Concept Study for Clinical and Educational Applications

    by Mathieu Hivert, Cyril Bengler, Julien De Jonckheere, Franck Gaultier, Marie Pécout, Olivier Mayeur, Chrystèle Rubod

    Objective: To develop and validate a device that measures the pressure exerted by forceps on the fetal head for clinical use. Background: The lack of clinical tools to quantify forceps pressure on the fetal head may impact maternal and neonatal outcomes. Existing studies have not measured the direct contact pressure between forceps blades and the fetal head, highlighting the need for innovation. Methods: We integrated fluid pressure transducers into obstetric forceps using fluid-filled tubing encased in flexible silicone socks attached to the blades. Tubing materials—polyvinyl chloride (PVC) and polyurethane (PU)—and fluids (air and water) were tested with both biocompatible and non-biocompatible silicone socks. An onboard electronic board collected pressure data and transmitted them via Bluetooth for real-time analysis. The system was evaluated on a custom-built bench simulating forceps application. Results: Air-filled tubing exhibited significant drift and low accuracy due to air compressibility. Water-filled PU tubing reduced drift but was still suboptimal. Water-filled PVC tubing with both types of silicone socks provided the best results, showing minimal drift and a strong correlation between measured pressures and applied forces. Conclusions: The developed device represents a significant advancement, as no existing system measures the pressure exerted by forceps blades on the fetal head. By effectively measuring pressure across the entire contact surface in real time, it offers applications in both training and clinical practice. The device allows for objective feedback, potentially improving the safety and efficacy of forceps deliveries. Future work includes comprehensive mannequin tests and eventual in vivo studies to validate its effectiveness in realistic settings, aiming to enhance obstetric training and reduce maternal and neonatal complications.


  • Open Access

    Mobility analysis of a posterior sacrospinous fixation using a finite element model of the pelvic system

    by Marine Lallemant, Andres Arteaga Shimojyo, Olivier Mayeur, Rajeev Ramanah, Chrystèle Rubod, Yohan Kerbage, Michel Cosson

    Introduction and hypothesis: In order to improve the knowledge POP physiopathology and POP repair, a generic biomechanical model of the female pelvic system has been developed. In the literature, no study has currently evaluated apical prolapse repair by posterior sacrospinous ligament fixation using a generic model nor a patient-specific model that personalize the management of POP and predict surgical outcomes based on the patient’s pre-operative Magnetic Resonance Imaging. The aim of our study was to analyze the influence of a right and/or left sacrospinous ligament fixation and the distance between the anchorage area and the ischial spine on the pelvic organ mobility using a generic and a patient-specific Finite Element model (FEM) of the female pelvic system during posterior sacrospinous ligament fixation (SSF). Methods: Firstly, we used a generic 3D FEM of the female pelvic system previously made by our team that allowed us to simulate the mobility of the pelvic system. To create a patient-specific 3D FEM of the female pelvic system, we used a preoperative dynamic pelvic MRI of a 68 years old woman with a symptomatic stage III apical prolapse and cystocele. With these 2 models, a SSF was simulated. A right and/or left SSF and different distances between the anchorage area and the ischial spine (1 cm, 2 cm and 3 cm.) were compared. Outcomes measures were the pelvic organ displacement using the pubococcygeal line during maximal strain: Ba point for the most posterior and inferior aspect of the bladder base, C point the cervix’s or the vaginal apex and Bp point for the anterior aspect of the anorectal junction. Results: Overall, pelvic organ mobility decreased regardless of surgical technique and model. According to the generic model, C point was displaced by 14.1 mm and 11.5 mm, Ba point by 12.7 mm, and 12 mm and Bp point by 10.6 mm and 9.9 mm after left and bilateral posterior SSF, respectively. C point was displaced by 15.4 mm and 11.6 mm and Ba point by 12.5 mm and 13.1mm when the suture on the sacrospinous ligament was performed at 1 cm and 3 cm from the ischial spine respectively (bilateral posterior SSF configuration). According to the patient-specific model, the displacement of Ba point could not be analyzed because of a significative and asymmetric organ displacement of the bladder. C point was displaced by 4.74 mm and 2.12 mm, and Bp point by 5.30 mm and 3.24 mm after left and bilateral posterior SSF respectively. C point was displaced by 4.80 mm and 4.85 mm and Bp point by 5.35 mm and 5.38 mm when the suture on the left sacrospinous ligament was performed at 1 cm and 3 cm from the ischial spine, respectively. Conclusion: According to the generic model from our study, the apex appeared to be less mobile in bilateral SSF. The anchorage area on the sacrospinous ligament seems to have little effect on the pelvic organ mobilities. Trial registration: ClinicalTrials.gov Identifier: NCT04551859.


  • Open Access

    Contributors

    by Steven Abramowitch, Laure Astruc, Stéphane Avril, Thiranja Prasad Babarenda Gamage, O. Bou Matar, Shaniel Bowen, Mathias Brieu, Michel Cosson, Hadrien Courtecuisse, John O.L. DeLancey, et al.