Qiong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qiong Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Xiaobao Liu
Provincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People’s Republic of China
2 shared publicationsYabo Fu
Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People’s Republic of China
2 shared publicationsYulong Huang
Provincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People’s Republic of China
2 shared publicationsChishan Kang
Provincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People’s Republic of China
1 shared publication- Han Lin
Shanghai Institute of Ceramics Chinese Academy of Sciences Research Unit of Nanocatalytic Medicine in Specific Therapy for Serious Disease Chinese Academy of Medical Sciences Shanghai 200050 China
1 shared publication - Hui Huang
Department of Environmental Health, College of Public Health, Zhengzhou University, Zhengzhou, Henan province, 450001, China
1 shared publication
Latest Publications
- Open Access
- 30 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Characteristics and factors associated with diameter deviation of rhexis reference circle generated by an image-guided system in cataract surgery: a cross-sectional study
More attention should be paid to the deviations between the actual diameter of the rhexis reference circle which projected by the Image-guided systems and its intended size, and assess the influence of ocular biometric parameters on the deviation. In this study, the Callisto eye image-guided system was employed to generate a digital rhexis reference circle (rhexis overlay) set at an intended diameter of 6 mm and a screenshot of the video was taken at the end of the cataract surgery, then to compare the deviation between the observed rhexis overlay diameter (ROD) and the optic diameter (6 mm). The factors influencing diameter deviation were identified with univariate and multivariate linear regression. Subgroup analyses were conducted based on factors identified in the multivariate regression. And we observed that a total of 213 eyes of 174 patients were included in the final analysis. The diameter deviation averaged − 0.24 ± 0.28 mm (P = 0.0001) and was positively correlated with phakic anterior chamber depth (ACD) (P < 0.001) and negatively correlated with white-to-white (WTW) measurement (P < 0.001). Subgroup analyses revealed significantly greater diameter deviation in cases with preoperative ACD < 2.5 mm and WTW ≥ 12.0 mm (all P < 0.05). Following optimization, the mean diameter deviation was 0.00047 ± 0.26 mm (P > 0.05). In conclusion, the Callisto eye image-guided system demonstrates good precision in CCC assistance. However, there remains a slight deviation from the intended size when generating the rhexis reference circle in eyes with shallow anterior chambers and larger corneas. Implementing an optimization process could be beneficial for these eyes.
- 30 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Open AccessCharacteristics and factors associated with diameter deviation of rhexis reference circle generated by an image-guided system in cataract surgery: a cross-sectional study
More attention should be paid to the deviations between the actual diameter of the rhexis reference circle which projected by the Image-guided systems and its intended size, and assess the influence of ocular biometric parameters on the deviation. In this study, the Callisto eye image-guided system was employed to generate a digital rhexis reference circle (rhexis overlay) set at an intended diameter of 6 mm and a screenshot of the video was taken at the end of the cataract surgery, then to compare the deviation between the observed rhexis overlay diameter (ROD) and the optic diameter (6 mm). The factors influencing diameter deviation were identified with univariate and multivariate linear regression. Subgroup analyses were conducted based on factors identified in the multivariate regression. And we observed that a total of 213 eyes of 174 patients were included in the final analysis. The diameter deviation averaged − 0.24 ± 0.28 mm (P = 0.0001) and was positively correlated with phakic anterior chamber depth (ACD) (P < 0.001) and negatively correlated with white-to-white (WTW) measurement (P < 0.001). Subgroup analyses revealed significantly greater diameter deviation in cases with preoperative ACD < 2.5 mm and WTW ≥ 12.0 mm (all P < 0.05). Following optimization, the mean diameter deviation was 0.00047 ± 0.26 mm (P > 0.05). In conclusion, the Callisto eye image-guided system demonstrates good precision in CCC assistance. However, there remains a slight deviation from the intended size when generating the rhexis reference circle in eyes with shallow anterior chambers and larger corneas. Implementing an optimization process could be beneficial for these eyes.
- 24 July 2024
- Published by Elsevier in Experimental Neurology
- Vol. 380, 114899
Resveratrol protects against a high-fat diet-induced neuroinflammation by suppressing mitochondrial fission via targeting SIRT1/PGC-1α
- 24 July 2024
- Published by Elsevier in Experimental Neurology
- Vol. 380, 114899
Resveratrol protects against a high-fat diet-induced neuroinflammation by suppressing mitochondrial fission via targeting SIRT1/PGC-1α
- Open Access
- 22 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0299064
Repeatability of Pentacam-derived intraocular lens decentration measurements and the level of agreement with OPD-Scan III: A prospective observational case series
Purpose: This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. Methods: In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. Results: A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. Conclusions: Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.
- 22 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0299064
Open AccessRepeatability of Pentacam-derived intraocular lens decentration measurements and the level of agreement with OPD-Scan III: A prospective observational case series
Purpose: This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. Methods: In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. Results: A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. Conclusions: Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.
- Open Access
- 11 October 2023
- Published by Austin Publishing Group in Austin Journal of Clinical Ophthalmology
- Vol. 10 (6)
Slipknot: An Ameliorated Technique for Pterygium Conjunctival Autograft
Conjunctival autograft was now the best method in pterygium operation. An absorbable suture with slipknot was used to fix the grafts of pterygium. A week after the surgery, most of the stitches had disintegrated and fallen out. This easy technique reduces the postoperative pain and the conjunctival reaction in the early postoperative period. It enables the surgeon to eliminate the need for postoperative suture removal, and relieve the patient’s anxiety of removing stitches during the review.
- 11 October 2023
- Published by Austin Publishing Group in Austin Journal of Clinical Ophthalmology
- Vol. 10 (6)
Open AccessSlipknot: An Ameliorated Technique for Pterygium Conjunctival Autograft
Conjunctival autograft was now the best method in pterygium operation. An absorbable suture with slipknot was used to fix the grafts of pterygium. A week after the surgery, most of the stitches had disintegrated and fallen out. This easy technique reduces the postoperative pain and the conjunctival reaction in the early postoperative period. It enables the surgeon to eliminate the need for postoperative suture removal, and relieve the patient’s anxiety of removing stitches during the review.
- 7 April 2022
- Published by Wolters Kluwer Health in Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi = Chinese Journal of Otorhinolaryngology Head and Neck Surgery
- Vol. 57 (4) , 501-502
[A case of mediastinal foreign body caused by esophageal magnetic beads].
- 7 April 2022
- Published by Wolters Kluwer Health in Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi = Chinese Journal of Otorhinolaryngology Head and Neck Surgery
- Vol. 57 (4) , 501-502
[A case of mediastinal foreign body caused by esophageal magnetic beads].