Huang Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huang Gao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bocong Li
Key Laboratory for Soft Chemistry and Functional Materials of Ministry of Education School of Chemistry and Chemical Engineering Nanjing University of Science and Technology Nanjing Jiangsu 210094 China
1 shared publication - Guoqiang Xiang
School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, People’s Republic of China
1 shared publication - Hangchao Zhou1 shared publication
Hao Guo
Institute of marine equipment and technology Jiangsu university of science and technology Zhenjiang China
1 shared publicationHuamin Zhou
State Key Lab of Material Processing and Die & Mold Technology Huazhong University of Science and Technology Wuhan China
1 shared publicationJing You
Teaching and Research Guarantee Center, Radar Sergeant School of Air Force Early Warning Academy Wuhan China
1 shared publication
Latest Publications
- Open Access
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
A multi-mode density measurement method for the high-density diamagnetic substances using horizontal magnetic levitation
To overcome the shortcomings of existing magnetic levitation density measurement methods, such as a narrow measurement range (0.8~2.3 g/cm³) and cumbersome operation when expanding their measurement range, a novel density measurement method for high-density diamagnetic substances is proposed. In this method, the high-density substance is placed on an adjustable inclined plate, and both are positioned in a horizontally placed magnetic levitation device. By adjusting the angle of the inclined plate, the sample can achieve levitation in the device under the combined action of gravity, buoyancy, normal force, and magnetic force. Based on the analysis of the forces on the substance in the paramagnetic solution, the distance between the substance and the center of the left magnet surface as well as the angle of the inclined plate are measured, and a correlation function among the distance, angle, and density is established. Accurate measurement of the density of high-density substances is achieved based on this functional relationship. Meanwhile, this function provides three measurement modes, namely linear, non-linear, and arbitrary-position methods, to cope with different density measurement scenarios, and finally a comprehensive surface graph of measurable density is obtained. Experimental results show that this method can measure the density of small-volume high-density samples (such as copper, tin, zirconia ceramic, aluminum, and glass). It achieves an expanded measurement range and more straightforward operation.
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA multi-mode density measurement method for the high-density diamagnetic substances using horizontal magnetic levitation
To overcome the shortcomings of existing magnetic levitation density measurement methods, such as a narrow measurement range (0.8~2.3 g/cm³) and cumbersome operation when expanding their measurement range, a novel density measurement method for high-density diamagnetic substances is proposed. In this method, the high-density substance is placed on an adjustable inclined plate, and both are positioned in a horizontally placed magnetic levitation device. By adjusting the angle of the inclined plate, the sample can achieve levitation in the device under the combined action of gravity, buoyancy, normal force, and magnetic force. Based on the analysis of the forces on the substance in the paramagnetic solution, the distance between the substance and the center of the left magnet surface as well as the angle of the inclined plate are measured, and a correlation function among the distance, angle, and density is established. Accurate measurement of the density of high-density substances is achieved based on this functional relationship. Meanwhile, this function provides three measurement modes, namely linear, non-linear, and arbitrary-position methods, to cope with different density measurement scenarios, and finally a comprehensive surface graph of measurable density is obtained. Experimental results show that this method can measure the density of small-volume high-density samples (such as copper, tin, zirconia ceramic, aluminum, and glass). It achieves an expanded measurement range and more straightforward operation.
- 16 March 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (21)
Crystallinity and mechanical properties of polypropylene products foamed by microcellular injection molding process
Microcellular injection molding (MIM) is a pivotal technique for lightweight molding. Polypropylene (PP) is widely used in MIM due to light weight and easy processing. The crystallinity of foamed PP products influences the load‐bearing structures and consequently mechanical properties. To address the deterioration of mechanical properties caused by internal porous structure, a novel method is proposed to regulate the crystallinity by optimizing process parameters, thereby improving mechanical properties. Wide‐angle x‐ray diffraction, mechanical testing, and melt flow simulation are applied to investigate the influence of process parameters on crystallinity and mechanical properties. Parameters are further optimized by establishing a multivariate nonlinear regression model for process parameters and crystallinity. The results show that increasing melt temperature, injection rate, mold temperature, and cooling time stimulate crystallization, enhancing strength and decreasing elongation at break. Conversely, high injection ratio of supercritical fluid obstructs crystallization, reducing strength, and increasing elongation at break. The crystallinity increases by 20.81%; the corresponding tensile, flexural, and shear strength and corresponding modulus increases by 5.39% and 10.28%, 7.60% and 18.50%, 5.00% and 11.37%, and elongation at break decreased by 5.19% through the optimization of regression model. The proposed method is feasible to upgrade the mechanical properties of foamed PP products.
- 16 March 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (21)
Crystallinity and mechanical properties of polypropylene products foamed by microcellular injection molding process
Microcellular injection molding (MIM) is a pivotal technique for lightweight molding. Polypropylene (PP) is widely used in MIM due to light weight and easy processing. The crystallinity of foamed PP products influences the load‐bearing structures and consequently mechanical properties. To address the deterioration of mechanical properties caused by internal porous structure, a novel method is proposed to regulate the crystallinity by optimizing process parameters, thereby improving mechanical properties. Wide‐angle x‐ray diffraction, mechanical testing, and melt flow simulation are applied to investigate the influence of process parameters on crystallinity and mechanical properties. Parameters are further optimized by establishing a multivariate nonlinear regression model for process parameters and crystallinity. The results show that increasing melt temperature, injection rate, mold temperature, and cooling time stimulate crystallization, enhancing strength and decreasing elongation at break. Conversely, high injection ratio of supercritical fluid obstructs crystallization, reducing strength, and increasing elongation at break. The crystallinity increases by 20.81%; the corresponding tensile, flexural, and shear strength and corresponding modulus increases by 5.39% and 10.28%, 7.60% and 18.50%, 5.00% and 11.37%, and elongation at break decreased by 5.19% through the optimization of regression model. The proposed method is feasible to upgrade the mechanical properties of foamed PP products.
- Open Access
- 13 July 2021
- Published by Sciencedomain International in Asian Journal of Chemical Sciences
- p. 38-46
Manganese-Doped Carbon Dots Via Inner Filter Effect for the Sensitive Detection of Tetracycline in Poultry Meat Samples
In this study, a rapid and sensitive analytical method has been developed to detect tetracycline hydrochloride (TC) using manganese-doped carbon dots (Mn-CDs) prepared by one-step hydrothermal procedure using 1-(2-pyridinylazo)-2-naohthalenol (PAN) and MnCl2 as precursor reagents. The obtained Mn-CDs showed an ultraviolet emission at 360 nm with an excitation wavelength of 300 nm. TC has a strong characteristic absorption peak at 356 nm, which has a large spectral overlap with the emission band of the Mn-CDs. The fluorescence intensity (FI) of Mn-CDs at 360 nm is linearly quenched within the TC concentration range of 0.1-200 µM. The developed assay for the detection of TC was based on an inner filter effect (IFE) mechanism and is rapid, sensitive, and was successfully applied for the determination of TC in different poultry meat samples with satisfactory results.
- 13 July 2021
- Published by Sciencedomain International in Asian Journal of Chemical Sciences
- p. 38-46
Open AccessManganese-Doped Carbon Dots Via Inner Filter Effect for the Sensitive Detection of Tetracycline in Poultry Meat Samples
In this study, a rapid and sensitive analytical method has been developed to detect tetracycline hydrochloride (TC) using manganese-doped carbon dots (Mn-CDs) prepared by one-step hydrothermal procedure using 1-(2-pyridinylazo)-2-naohthalenol (PAN) and MnCl2 as precursor reagents. The obtained Mn-CDs showed an ultraviolet emission at 360 nm with an excitation wavelength of 300 nm. TC has a strong characteristic absorption peak at 356 nm, which has a large spectral overlap with the emission band of the Mn-CDs. The fluorescence intensity (FI) of Mn-CDs at 360 nm is linearly quenched within the TC concentration range of 0.1-200 µM. The developed assay for the detection of TC was based on an inner filter effect (IFE) mechanism and is rapid, sensitive, and was successfully applied for the determination of TC in different poultry meat samples with satisfactory results.