SLSang Hyuk Lee

Sang Hyuk Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sang Hyuk Lee has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Enusha Karunasena

    Affiliation Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration (FDA), Silver Spring, MD, United States of America

    3 shared publications
  • Marc Donohue

    Johns Hopkins University

    2 shared publications
  • Michael Keidar

    Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, United States of America

    2 shared publications
  • Steve Wood

    Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration (FDA), Silver Spring, MD, United States of America

    2 shared publications
  • Vikas Soni

    Micropropulsion and Nanotechnology Laboratory (MPNL), School of Engineering and Applied Science, George Washington University, 800 22nd St. NW, Suite 3100, Washington, DC 20052, USA

    2 shared publications
  • William Kastor

    Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration (FDA), Silver Spring, MD, United States of America

    2 shared publications

Latest Publications

  • Open Access

    Development and application of decontamination methods for the re-use of laboratory grade plastic pipette tips

    by Sang Hyuk Lee, William Kastor, Xiao Fu, Vikas Soni, Michael Keidar, Marc Donohue, Steve Wood, Enusha Karunasena

    During the SARS-CoV-2 pandemic, a need for methods to decontaminate and reuse personal protective equipment (PPE) and medical plastics became a priority. In this investigation we aimed to develop a contamination evaluation protocol for laboratory pipette tips, after decontamination. Decontamination methods tested in this study included cleaning with a common laboratory detergent (2.5% Alconox® solution followed with steam decontamination), exposure of ozone vapor at 250 and 14400 PPM * minute, and exposure to cold atmospheric plasma (CAP). All tips (control and experimental groups) were introduced to the methods described, while tips exposed to DNA extracts of Aeromonas hydrophila (ATCC-23211) were assessed for experimental groups. Decontamination was determined by turnover ratio and log reduction in detectable genomic material on the contaminated products using real-time quantitative PCR (qPCR) assay. Our results showed, cleaning tips with lab detergents along with steam decontamination removed genetic material, resulting in the highest log reduction, compared with ozone or CAP treatments. Detergent/washing methods showed the second highest turnover ratio (95.9%) and log reduction (5.943). However, the excessive residue (post- cleaning) on the plastic, within inner filters, and tip boxes suggested that washing with lab detergents was not favorable for reuse. Ozone vapor at 14400 PPM * minute showed the highest turnover ratio (98.4%) and log reduction (4.511). CAP exposure with tips inverted (the tip end exposed closer to the plasma flame) for 1 minute showed a turnover ratio of (68.3%) and log reduction (4.002). Relatively, lower turnover ratio and log reduction of CAP could be improved by optimization, such as increasing the exposure time. Future testing would provide fine-tuned conditions for CAP-specific decontamination of plasticware. In this study we were able to provide fundamental insight into a non-traditional decontamination method for single-use plasticware that could render these products reusable.


  • Open Access

    Development and Application of Decontamination Methods for the Re-Use of Laboratory Grade Plastic Pipette Tips

    by Sang Hyuk Lee, William Kastor, Xiao Fu, Vikas Soni, Michael Keidar, Marc Donohue, Steve Wood, Enusha Karunasena

    During the SARS-CoV-2 pandemic, a need for methods to decontaminate and reuse personal protective equipment (PPE) and medical plastics became a priority. In this investigation we aimed to develop a contamination evaluation protocol for laboratory pipette tips, after decontamination. Decontamination methods tested in this study included cleaning with a common laboratory detergent (2.5% Alconox® solution followed with steam decontamination), exposure of ozone vapor at 250 and 14400 PPM * minute, and exposure to cold atmospheric plasma (CAP). All tips (control and experimental groups) were introduced to the methods described, while tips exposed to DNA extracts of Aeromonas hydrophila (ATCC-23211) were assessed for experimental groups. Decontamination was determined by turnover ratio and log reduction in detectable genomic material on the contaminated products using real-time quantitative PCR (qPCR) assay. Our results showed, cleaning tips with lab detergents along with steam decontamination removed genetic material, resulting in the highest log reduction, compared with ozone or CAP treatments. Detergent/washing methods showed the highest turnover ratio (95.9 %) and log reduction (5.943). However, the excessive residue (post-cleaning) on the plastic, within inner filters, and tip boxes suggested that washing with lab detergents was not favorable for reuse. Ozone vapor at 14400 PPM * minutes showed the second highest turnover ratio (98.4 %) and log reduction (4.511). CAP exposure with tips inverted (the tip end exposed closer to the plasma flame) for 1 minute showed a turnover ratio of (68.3 %) and log reduction (4.002). Relatively, lower turnover ratio and log reduction of CAP could be attributed to development/optimization of treatment conditions, including increases in exposure time and relative to tip positioning.

  • Open Access

    Modified in-vitro AATCC-100 procedure to measure viable bacteria from wound dressings

    by Sang Hyuk Lee, Thomas Glover, Nathan Lavey, Xiao Fu, Marc Donohue, Enusha Karunasena

    Chronic wounds are reoccurring healthcare problems in the United States and cost up to $50 billion annually. Improper wound care results in complications such as wound debridement, surgical amputation, and increased morbidity/ mortality due to opportunistic infections. To eliminate wound infections, many antimicrobial dressings are developed and submitted to FDA for evaluation. AATCC-100 is a standard method widely used to evaluate cloth wound dressings. This method, requires enrichment, followed by culturing to measure the concentration of culturable organisms; a caveat to this method could result in neglected viable but nonculturable (VBNC) bacteria and overestimate the antimicrobial properties of wound dressings. Therefore, the objectives of this study were to assess this accepted protocol with quantitative real-time polymerase chain reaction (qRT-PCR), to measure time dependent antimicrobial efficacy of wound dressing, and to examine for potential viable bacteria but non-culturable as compared with traditional plating methods. The test organisms included opportunistic pathogens: Pseudomonas aeruginosa (ATCC 15692) and Staphylococcus aureus (ATCC 43300). To mimic a wound dressing environment, samples of commercially available wound dressings (McKesson Inc.) with silver ion (positive control) and dressings without silver ion (positive control) were assessed under sterile conditions. All samples were examined by the original protocol (the extended AATCC-100 method) and qRT-PCR. The expression of specific housekeeping genes was measured (proC for P. aeruginosa and 16s rRNA for S. aureus). Based on these tests, log reduction of experimental conditions was compared to identify time dependent and precise antimicrobial properties from wound dressing samples. These results showed antimicrobial properties of wound dressings diminished as incubation days are increased for both methods from day 1 PCR result of 4.31 ± 0.54 and day 1 plating result of 6.31 ± 3.04 to day 3 PCR result of 1.22 ± 0.97 and day 3 plating result of 5.89 ± 2.41. These results show that data from qRT-PCR generally produced lower standard deviation than that of culture methods, hence shown to be more precise. Complementary parallel analysis of samples using both methods better characterized antimicrobial properties of the tested samples.