Yu Mb Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yu Mb Huang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Bei Jiang
Nursing Department, Hainan Chengmei Hospital, Haikou, China
1 shared publication- Nan Mm Yang
Department of Respiratory Medicine, Affiliated Cancer Hospital of Hainan Medical University, Hainan Cancer Hospital, Haikou, China
1 shared publication - Tongyuan Mb Wang
Department of Respiratory Medicine, Affiliated Cancer Hospital of Hainan Medical University, Hainan Cancer Hospital, Haikou, China
1 shared publication - Wen Dong
Department of Respiratory Medicine, Hainan Cancer Hospital, Haikou, China
1 shared publication - Zhen Mm Jia
Department of Anesthesiology, Hainan Cancer Hospital, Haikou, China
1 shared publication
Latest Publications
- Open Access
- 17 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (46) , e36164
To establish a risk prediction model for the occurrence of hypoxemia during painless bronchoscopy
The present study was focused on evaluating the clinical predictors of hypoxemia and establishing a multivariable, predictive model for hypoxemia in painless bronchoscopy. A total of 244 patients were enrolled in the study, and data were collected using a self-designed data collection. The retrospective data collected in this study included the relevant data of patients undergoing the painless bronchoscopy, and we used univariate analysis to deal with these influencing factors. Multivariate logistic regression analysis was used to establish the prediction equation, and receiver operating characteristic curve analysis was carried out. Receiver operating characteristic curves and the Hosmer–Lemeshow test were used to evaluate the model performance. P < .05 was considered to indicate statistical significance. Multivariate logistic regression indicated that body mass index (BMI) (odds ratio [OR]: 1.169; 95% confidence interval [CI]: 1.070–1.277), arterial partial pressure of oxygen (PaO2) (OR: 4.279; 95% CI: 2.378–7.699), alcohol consumption (OR: 2.021; 95% CI: 1.063–3.840), and whether the bronchoscope operation time exceeds 30 minutes (OR: 2.486; 95% CI: 1.174–5.267) were closely related to the occurrence of hypoxemia. The prediction model developed by the logistic regression equation was −4.911 + 1.454 (PaO2) + 0.156 (BMI) + 0.703 (Alcohol consumption) + 0.911 (time > 30th minutes). The prediction model showed that the area under the receiver operating characteristic curve was 0.687. The predictive model was well calibrated with a Hosmer–Lemeshow x 2 statistic of 4.869 (P = .772), indicating that our prediction model fit well. The accuracy (number of correct predictions divided by the number of total predictions) was 75%. The prediction model, consisting of BMI, PaO2, alcohol consumption, and whether the bronchoscope operation time exceeds 30 minutes. It is an effective predictor of hypoxemia during sedation for painless bronchoscopy.
- 17 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (46) , e36164
Open AccessTo establish a risk prediction model for the occurrence of hypoxemia during painless bronchoscopy
The present study was focused on evaluating the clinical predictors of hypoxemia and establishing a multivariable, predictive model for hypoxemia in painless bronchoscopy. A total of 244 patients were enrolled in the study, and data were collected using a self-designed data collection. The retrospective data collected in this study included the relevant data of patients undergoing the painless bronchoscopy, and we used univariate analysis to deal with these influencing factors. Multivariate logistic regression analysis was used to establish the prediction equation, and receiver operating characteristic curve analysis was carried out. Receiver operating characteristic curves and the Hosmer–Lemeshow test were used to evaluate the model performance. P < .05 was considered to indicate statistical significance. Multivariate logistic regression indicated that body mass index (BMI) (odds ratio [OR]: 1.169; 95% confidence interval [CI]: 1.070–1.277), arterial partial pressure of oxygen (PaO2) (OR: 4.279; 95% CI: 2.378–7.699), alcohol consumption (OR: 2.021; 95% CI: 1.063–3.840), and whether the bronchoscope operation time exceeds 30 minutes (OR: 2.486; 95% CI: 1.174–5.267) were closely related to the occurrence of hypoxemia. The prediction model developed by the logistic regression equation was −4.911 + 1.454 (PaO2) + 0.156 (BMI) + 0.703 (Alcohol consumption) + 0.911 (time > 30th minutes). The prediction model showed that the area under the receiver operating characteristic curve was 0.687. The predictive model was well calibrated with a Hosmer–Lemeshow x 2 statistic of 4.869 (P = .772), indicating that our prediction model fit well. The accuracy (number of correct predictions divided by the number of total predictions) was 75%. The prediction model, consisting of BMI, PaO2, alcohol consumption, and whether the bronchoscope operation time exceeds 30 minutes. It is an effective predictor of hypoxemia during sedation for painless bronchoscopy.