Won Mo Koo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Won Mo Koo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Seongho Woo
Department of Physical Medicine and Rehabilitation, Daegu Fatima Hospital, Daegu-si 41121, Republic of Korea
2 shared publications - Byung Joo Lee
Department of Rehabilitation Medicine, Daegu Fatima Hospital, Daegu 41199, Korea
1 shared publication - Hyoshin Eo
Department of Physical Medicine and Rehabilitation, Daegu Fatima Hospital, Dong-gu, Daegu, South Korea
1 shared publication Jeeihn Lee
Department of Physical Medicine and Rehabilitation, Suseong Children’s Hospital, Suseong, Daegu, South Korea
1 shared publicationJong Min Kim
Department of Physical Medicine and Rehabilitation, Daegu Fatima Hospital, Dong-gu, Daegu, South Korea
1 shared publication- Jong-Moon Hwang
Department of Rehabilitation Medicine, Daegu Fatima Hospital, Daegu, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 24 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 375
Evaluation of a Novel Flexible Cage System for C5–C6 Fixation: A Finite Element Study Against Conventional ACDF Implants
Cervical spondylosis is a common cause of spinal cord dysfunction, and anterior cervical discectomy and fusion (ACDF) is widely employed when conservative treatment fails. Conventional implant systems such as the cervical cage with plate (CCP) and zero-profile stand-alone cage (ZPSC) are commonly used to enhance spinal stability and promote fusion, but they are associated with complications including dysphagia and adjacent segment degeneration. To address these limitations, a novel flexible plate cage system (FPCS) has been developed to optimize biomechanical performance while minimizing surgical risk. In this study, a finite element model of the C3–T1 cervical spine was constructed to simulate ACDF at the C5–C6 level using CCP, ZPSC, and FPCS implants. Under standardized loading conditions, von Mises stress was analyzed in the bone, intervertebral disc, endplates, cage, and screws, using the mean of the top 5% stress values to ensure accuracy. All surgical models showed increased stress compared to the intact reference spine. The ZPSC model exhibited the highest stress in the cage and screws, suggesting a more concentrated load path. The CCP model showed a more evenly distributed stress profile, particularly affecting the inferior adjacent segment. The FPCS model demonstrated moderate cage stress, reduced screw stress, and the highest plate stress, indicating a design that effectively redirects mechanical load from the screw-bone interface toward the anterior plate. This may be related to the unique structural configuration of the FPCS, which secures screws horizontally into the anterior vertebral body without penetrating the endplates. These findings suggest that the FPCS may offer a biomechanically favorable alternative to existing ACDF implants.
- 24 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 375
Open AccessEvaluation of a Novel Flexible Cage System for C5–C6 Fixation: A Finite Element Study Against Conventional ACDF Implants
Cervical spondylosis is a common cause of spinal cord dysfunction, and anterior cervical discectomy and fusion (ACDF) is widely employed when conservative treatment fails. Conventional implant systems such as the cervical cage with plate (CCP) and zero-profile stand-alone cage (ZPSC) are commonly used to enhance spinal stability and promote fusion, but they are associated with complications including dysphagia and adjacent segment degeneration. To address these limitations, a novel flexible plate cage system (FPCS) has been developed to optimize biomechanical performance while minimizing surgical risk. In this study, a finite element model of the C3–T1 cervical spine was constructed to simulate ACDF at the C5–C6 level using CCP, ZPSC, and FPCS implants. Under standardized loading conditions, von Mises stress was analyzed in the bone, intervertebral disc, endplates, cage, and screws, using the mean of the top 5% stress values to ensure accuracy. All surgical models showed increased stress compared to the intact reference spine. The ZPSC model exhibited the highest stress in the cage and screws, suggesting a more concentrated load path. The CCP model showed a more evenly distributed stress profile, particularly affecting the inferior adjacent segment. The FPCS model demonstrated moderate cage stress, reduced screw stress, and the highest plate stress, indicating a design that effectively redirects mechanical load from the screw-bone interface toward the anterior plate. This may be related to the unique structural configuration of the FPCS, which secures screws horizontally into the anterior vertebral body without penetrating the endplates. These findings suggest that the FPCS may offer a biomechanically favorable alternative to existing ACDF implants.
- Open Access
- 17 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (46) , e36058
Long-term changes of standing balance after lateral ankle sprain using Footscan system: A case report
Rationale: A lateral ankle sprain (LAS) is a common sports related injury. Ankle instability and balance impairment after injury are common. This case report describes the longitudinal changes in static balance after LAS. Patient concerns: A 36-year-old man visited our hospital with LAS of the right ankle that occurred during an exercise session. The patient complained of severe pain and swelling of the ankle. The patient was unable to walk a short distance. Diagnoses: Ultrasound examination showed swelling of the surrounding soft tissues and a partial tear of the right anterior talofibular ligament. In the Doppler scan, vascularity increased around anterior talofibular ligament. No fractures were observed on computed tomography. Interventions: The patient received analgesics for pain control. The rest, ice, compression, elevation protocol was used. The injured area was protected with a controlled ankle movement walking boot for 2 weeks. Standing balance was measured at 3, 4, 8, 12, and 24 weeks after injury using Footscan. Outcome: He was able to walk approximately 2 weeks after the injury with reduced pain over time. It was observed that the standing balance improved over time. Lesson: In this case, it was objectively confirmed that standing balance was restored naturally after LAS.
- 17 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (46) , e36058
Open AccessLong-term changes of standing balance after lateral ankle sprain using Footscan system: A case report
Rationale: A lateral ankle sprain (LAS) is a common sports related injury. Ankle instability and balance impairment after injury are common. This case report describes the longitudinal changes in static balance after LAS. Patient concerns: A 36-year-old man visited our hospital with LAS of the right ankle that occurred during an exercise session. The patient complained of severe pain and swelling of the ankle. The patient was unable to walk a short distance. Diagnoses: Ultrasound examination showed swelling of the surrounding soft tissues and a partial tear of the right anterior talofibular ligament. In the Doppler scan, vascularity increased around anterior talofibular ligament. No fractures were observed on computed tomography. Interventions: The patient received analgesics for pain control. The rest, ice, compression, elevation protocol was used. The injured area was protected with a controlled ankle movement walking boot for 2 weeks. Standing balance was measured at 3, 4, 8, 12, and 24 weeks after injury using Footscan. Outcome: He was able to walk approximately 2 weeks after the injury with reduced pain over time. It was observed that the standing balance improved over time. Lesson: In this case, it was objectively confirmed that standing balance was restored naturally after LAS.