Valentin Vervack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Valentin Vervack has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Vandeweghe
Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium
4 shared publications Camilla Johansson
Faculty of Odontology, Material Science and Technology, Dental Technology Malmö University Malmö Sweden
1 shared publicationEvaggelia Papia
Faculty of Odontology, Material Science and Technology, Dental Technology Malmö University Malmö Sweden
1 shared publication- Haider Ali Ibrahim
Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq
1 shared publication Haider Hasan Jasim
Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq
1 shared publication- Hugo De Bruyn
Department of Periodontology and Oral Implantology, Oral Health Sciences, Faculty of Medicine and Health Sciences, Ghent University, Corneel Heymanslaan 10, 9000 Ghent, Belgium
1 shared publication
Latest Publications
- Open Access
Effect of Two Different Adhesion Modes of a Universal Resin Cement on the Retention of Glass Fiber Posts Cemented to Root Canal Dentine: An In Vitro Study
Purpose: The aim of this in vitro study was to investigate the adhesive bond strength of glass fiber posts when cemented with universal resin cement in two different adhesion modes: adhesive and self-adhesive. Methods: A total of 20 extracted single-root teeth were endodontically treated, decoronated and prepared to receive glass fiber posts (GFPs) with a diameter of 1.6 mm (RelyX fiber post 3D). Specimens were randomly divided into two groups: (G1) GFPs were cemented using RelyX Universal cement in self-adhesive mode, and (G2) GFPs were cemented using Scotch Bond Universal Plus and RelyX Universal cement (adhesive mode). Afterwards, the specimens were sliced at three root levels: coronal, middle and apical. Bond strength was measured using a push-out test. Data were analyzed with a two-way analysis of variance (ANOVA) test and independent sample T-test. Results: Bond strength was significantly influenced by the adhesive strategy (p < 0.025) and the position of the root third (p < 0.007). Microscopic analysis of failure mode revealed a higher prevalence of adhesive failures (cement–dentine). Conclusions: Glass fiber posts cemented with universal resin cement applied in adhesive mode showed significantly higher push-out bond strength than when applied in self-adhesive mode. In both study groups, the apical root regions exhibited the highest retention values, followed by the middle and coronal regions.
Open AccessEffect of Two Different Adhesion Modes of a Universal Resin Cement on the Retention of Glass Fiber Posts Cemented to Root Canal Dentine: An In Vitro Study
Purpose: The aim of this in vitro study was to investigate the adhesive bond strength of glass fiber posts when cemented with universal resin cement in two different adhesion modes: adhesive and self-adhesive. Methods: A total of 20 extracted single-root teeth were endodontically treated, decoronated and prepared to receive glass fiber posts (GFPs) with a diameter of 1.6 mm (RelyX fiber post 3D). Specimens were randomly divided into two groups: (G1) GFPs were cemented using RelyX Universal cement in self-adhesive mode, and (G2) GFPs were cemented using Scotch Bond Universal Plus and RelyX Universal cement (adhesive mode). Afterwards, the specimens were sliced at three root levels: coronal, middle and apical. Bond strength was measured using a push-out test. Data were analyzed with a two-way analysis of variance (ANOVA) test and independent sample T-test. Results: Bond strength was significantly influenced by the adhesive strategy (p < 0.025) and the position of the root third (p < 0.007). Microscopic analysis of failure mode revealed a higher prevalence of adhesive failures (cement–dentine). Conclusions: Glass fiber posts cemented with universal resin cement applied in adhesive mode showed significantly higher push-out bond strength than when applied in self-adhesive mode. In both study groups, the apical root regions exhibited the highest retention values, followed by the middle and coronal regions.
- 26 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107033
Comparative evaluation of bilayered and monolithic endocrowns: Fracture resistance, failure mode, and stress distribution
- 26 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107033
Comparative evaluation of bilayered and monolithic endocrowns: Fracture resistance, failure mode, and stress distribution
- 28 December 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (5) , 796-803
The fracture strength and the failure mode of lithium disilicate or resin nano ceramics as a crown, overlay, or endocrown restoration on endodontically treated teeth
Introduction: Different materials and restorative concepts have been proposed over the years to restore endodontically treated teeth (ETT). Monolithic ceramic and composite restoration can be lute to the tooh, without the use of a post. However, little is known how the material stiffness and presence of a composite core will affect the survival and failure mode.The objective of this in‐vitro study was to evaluate the fracture strength and failure mode of endodontically treated molars, restored with ceramic or hybrid composite monolithic restoration, in the presence of absence of a composite core.Materials and Methods: Sixty depulped molars were restored with a lithium‐disilicate (e.max CAD) or hybrid composite (Cerasmart) restoration. Both materials were used in a monolithic approach, but with 3 different designs: (a) monolithic endocrown, (b) crown with a separate composite core, and (c) overlay without core buildup or pulpal extension. Ten sound teeth were used as control group. All groups were thermocycled (10,000 cycles), subsequently loaded in a chewing simulator (100,000 cycles) and finally loaded until fracture.Results: Peak fracture loads and failure modes were registered. No significant differences were seen between the groups in terms of fracture load. Failure modes were statistically significantly different among groups with significant correlation between restoration type and material. (p < 0.001 and p = 0.033, respectively). No group presented significantly higher fracture resistance. Although ceramic crowns and overlays presented the highest repairability, all restored ETT were within the range of the intact tooth' fracture strength.Conclusion: No restoration presented significant different fracture loads. However, the type of restoration and material choice were correlated to the fracture mode.
- 28 December 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (5) , 796-803
The fracture strength and the failure mode of lithium disilicate or resin nano ceramics as a crown, overlay, or endocrown restoration on endodontically treated teeth
Introduction: Different materials and restorative concepts have been proposed over the years to restore endodontically treated teeth (ETT). Monolithic ceramic and composite restoration can be lute to the tooh, without the use of a post. However, little is known how the material stiffness and presence of a composite core will affect the survival and failure mode.The objective of this in‐vitro study was to evaluate the fracture strength and failure mode of endodontically treated molars, restored with ceramic or hybrid composite monolithic restoration, in the presence of absence of a composite core.Materials and Methods: Sixty depulped molars were restored with a lithium‐disilicate (e.max CAD) or hybrid composite (Cerasmart) restoration. Both materials were used in a monolithic approach, but with 3 different designs: (a) monolithic endocrown, (b) crown with a separate composite core, and (c) overlay without core buildup or pulpal extension. Ten sound teeth were used as control group. All groups were thermocycled (10,000 cycles), subsequently loaded in a chewing simulator (100,000 cycles) and finally loaded until fracture.Results: Peak fracture loads and failure modes were registered. No significant differences were seen between the groups in terms of fracture load. Failure modes were statistically significantly different among groups with significant correlation between restoration type and material. (p < 0.001 and p = 0.033, respectively). No group presented significantly higher fracture resistance. Although ceramic crowns and overlays presented the highest repairability, all restored ETT were within the range of the intact tooth' fracture strength.Conclusion: No restoration presented significant different fracture loads. However, the type of restoration and material choice were correlated to the fracture mode.
- Open Access
- 24 July 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (15) , 3269
Clinical Evaluation of Resin Composite CAD/CAM Restorations Placed by Undergraduate Students
To evaluate the clinical outcomes of resin composite CAD/CAM restorations in a prospective cohort study, and to assess patient and operator satisfaction after restoration placement, 59 indirect resin composite were placed by supervised undergraduate students, of which 43 restorations were followed over a mean period of 28 months (14–44 months) and evaluated using USPHS criteria. Patient and operator satisfaction levels were assessed using a visual analogue scale (VAS) after restoration placement. A total of 37 patients and 47 restorations were included for further study. Four teeth were extracted—three due to extensive drug-induced secondary caries in the same patient, and one tooth due to large periapical periodontitis after 44 months of service. The overall survival rate was 91.4%, and success rate was 87.2%. Differences between baseline and endpoint scores were significant for marginal discoloration (p < 0.05) and adaptation (p < 0.001). Color match (p < 0.05) and surface texture (p < 0.001) differed significantly, affecting all restoration types. VAS scores for patient and operator satisfaction showed a significant rank correlation (p < 0.01), and pairwise comparison showed significant differences for mean overall patient and operator VAS scores (p < 0.001). Lava Ultimate CAD/CAM may be considered a suitable material for overlays and endocrown restorations when combined with IDS, air abrasion, and MDP-containing adhesive systems. Marginal disintegration may present in inlays and onlays over time.
- 24 July 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (15) , 3269
Open AccessClinical Evaluation of Resin Composite CAD/CAM Restorations Placed by Undergraduate Students
To evaluate the clinical outcomes of resin composite CAD/CAM restorations in a prospective cohort study, and to assess patient and operator satisfaction after restoration placement, 59 indirect resin composite were placed by supervised undergraduate students, of which 43 restorations were followed over a mean period of 28 months (14–44 months) and evaluated using USPHS criteria. Patient and operator satisfaction levels were assessed using a visual analogue scale (VAS) after restoration placement. A total of 37 patients and 47 restorations were included for further study. Four teeth were extracted—three due to extensive drug-induced secondary caries in the same patient, and one tooth due to large periapical periodontitis after 44 months of service. The overall survival rate was 91.4%, and success rate was 87.2%. Differences between baseline and endpoint scores were significant for marginal discoloration (p < 0.05) and adaptation (p < 0.001). Color match (p < 0.05) and surface texture (p < 0.001) differed significantly, affecting all restoration types. VAS scores for patient and operator satisfaction showed a significant rank correlation (p < 0.01), and pairwise comparison showed significant differences for mean overall patient and operator VAS scores (p < 0.001). Lava Ultimate CAD/CAM may be considered a suitable material for overlays and endocrown restorations when combined with IDS, air abrasion, and MDP-containing adhesive systems. Marginal disintegration may present in inlays and onlays over time.
- 1 September 2017
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 35 (5) , 715-723
Immediate Implant Placement and Loading of Single Implants in the Esthetic Zone: Clinical Outcome and Esthetic Evaluation in a Japanese Population
Kenji Takeshita, DDS/Stefan Vandeweghe, DDS, PhD/Valentin Vervack, DDS/Takashi Sumi, DDS, PhD/Hugo De Bruyn, DDS, PhD/Ryo Jimbo, DDS, PhD: This study evaluated the clinical outcomes of immediately loaded maxillary anterior single implants placed in fresh extraction sockets. A patient cohort that was treated 1.5 years earlier was recalled, and 18 patients (6 men, 12 women) with 21 implants were included. Clinical photographs and periapical radiographs were taken at follow-up and baseline to determine the bone loss and change in esthetics. No marginal bone loss was detected at followup (mean bone level ? standard deviation = 0.32 ? 0.82 mm). Immediate implant placement and loading resulted in predictable clinical and esthetic outcomes, with soft and hard tissue levels remaining stable over time.
- 1 September 2017
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 35 (5) , 715-723
Immediate Implant Placement and Loading of Single Implants in the Esthetic Zone: Clinical Outcome and Esthetic Evaluation in a Japanese Population
Kenji Takeshita, DDS/Stefan Vandeweghe, DDS, PhD/Valentin Vervack, DDS/Takashi Sumi, DDS, PhD/Hugo De Bruyn, DDS, PhD/Ryo Jimbo, DDS, PhD: This study evaluated the clinical outcomes of immediately loaded maxillary anterior single implants placed in fresh extraction sockets. A patient cohort that was treated 1.5 years earlier was recalled, and 18 patients (6 men, 12 women) with 21 implants were included. Clinical photographs and periapical radiographs were taken at follow-up and baseline to determine the bone loss and change in esthetics. No marginal bone loss was detected at followup (mean bone level ? standard deviation = 0.32 ? 0.82 mm). Immediate implant placement and loading resulted in predictable clinical and esthetic outcomes, with soft and hard tissue levels remaining stable over time.