Saher Saeed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Saher Saeed has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ioannis Dimopoulos
Department of General-, Visceral-, Thoracic- and Endocrine Surgery, Johannes Wesling Hospital Minden, Germany
2 shared publicationsJan Robert Kröger
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling Hospital Minden, Germany
2 shared publicationsNehara Begum
Department of General-, Visceral-, Thoracic- and Endocrine Surgery, Johannes Wesling Hospital Minden, Germany
2 shared publications- Arwed Elias Michael
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
1 shared publication - Christoph Moenninghoff
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
1 shared publication - Denise Schoenbeck
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
1 shared publication
Latest Publications
- Open Access
- 2 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1413
Real-Time MR-Guided Lumbosacral Periradicular Injection Therapy Using a 0.55 T MRI System: A Phantom Study
Objective: The purpose of this study was to evaluate the accuracy and feasibility of magnetic resonance (MR)-guided periradicular nerve root injection therapy (PRT) using a 0.55 T magnetic resonance imaging (MRI) system with fast dynamic imaging in a phantom. Methods: Five radiologists with varying levels of experience in PRT performed nine randomly assigned PRT procedures: three under MR guidance, three under CT guidance using a fully integrated laser navigation system, and three under conventional CT guidance, all on a specialized phantom of the lumbar spine. The PRTs were assessed by two experienced neuroradiologists with expertise in interventions, using a scale of 1–5, as follows: 5 = excellent to very good, 4 = good, 3 = satisfactory 2 = bad, 1 = very bad. The puncture time and total intervention time were noted. Results: All procedures were technically successful. The subjective evaluation of the PRTs showed similar results with a median of 5 for all three guidance systems. Additionally, there was no significant difference with respect to pure puncture time (the period after needle path determination) among all PRTs (Mean ± SD): MR-guided 178 ± 117 s, CT-guided with laser system 186 ± 73 s, and the conventional CT-guided 218 ± 91 s (p = 0.482). However, the total procedure time including planning images was significantly higher for MR-guided PRT (700 ± 182 s) compared to CT guidance with laser system (366 ± 85 s) and conventional CT guidance (358 ± 150 s; p = 0.012). Conclusions: Real-time MRI-guided lumbosacral periradicular injection therapy utilizing a 0.55 T MRI system is feasible with similar puncture times to CT guidance but consumes more intervention time due to the duration of planning sequences. Limitation: The study utilized a stationary phantom made of homogeneous material, which provides an incomplete representation of real tissue properties and motion complexity applied to human beings.
- 2 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1413
Open AccessReal-Time MR-Guided Lumbosacral Periradicular Injection Therapy Using a 0.55 T MRI System: A Phantom Study
Objective: The purpose of this study was to evaluate the accuracy and feasibility of magnetic resonance (MR)-guided periradicular nerve root injection therapy (PRT) using a 0.55 T magnetic resonance imaging (MRI) system with fast dynamic imaging in a phantom. Methods: Five radiologists with varying levels of experience in PRT performed nine randomly assigned PRT procedures: three under MR guidance, three under CT guidance using a fully integrated laser navigation system, and three under conventional CT guidance, all on a specialized phantom of the lumbar spine. The PRTs were assessed by two experienced neuroradiologists with expertise in interventions, using a scale of 1–5, as follows: 5 = excellent to very good, 4 = good, 3 = satisfactory 2 = bad, 1 = very bad. The puncture time and total intervention time were noted. Results: All procedures were technically successful. The subjective evaluation of the PRTs showed similar results with a median of 5 for all three guidance systems. Additionally, there was no significant difference with respect to pure puncture time (the period after needle path determination) among all PRTs (Mean ± SD): MR-guided 178 ± 117 s, CT-guided with laser system 186 ± 73 s, and the conventional CT-guided 218 ± 91 s (p = 0.482). However, the total procedure time including planning images was significantly higher for MR-guided PRT (700 ± 182 s) compared to CT guidance with laser system (366 ± 85 s) and conventional CT guidance (358 ± 150 s; p = 0.012). Conclusions: Real-time MRI-guided lumbosacral periradicular injection therapy utilizing a 0.55 T MRI system is feasible with similar puncture times to CT guidance but consumes more intervention time due to the duration of planning sequences. Limitation: The study utilized a stationary phantom made of homogeneous material, which provides an incomplete representation of real tissue properties and motion complexity applied to human beings.
- 25 March 2024
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 63 (02) , 78-80
Intrapankreatische Nebenmilz imitiert NET mit falsch positivem Somatostatin-Rezeptor-PET/CT (68Ga-DOTA-TOC-PET/CT)
Nebenmilzen finden sich in großen Sektionsstatistiken in 10–15 % der Fälle. Dabei ist das ektope Milzgewebe aufgrund seiner Embryogenese in 80 % der Fälle im Bereich des Milzhilus und nur in 1–2 % im Pankreasschwanz lokalisiert [Meyer T et al. „Intrapankreatische Nebenmilz als Differenzialdiagnose des Pankreasschwanzkarzinomes.“ Zentralblatt für Chirurgie 132.01 (2007): 73–76]. Weitere mögliche Lokalisationen für eine Nebenmilz sind das Ligamentum gastrosplenicum, das Ligamentum splenorenale und das Omentum majus. Article published online: 25 March 2024 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 25 March 2024
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 63 (02) , 78-80
Intrapankreatische Nebenmilz imitiert NET mit falsch positivem Somatostatin-Rezeptor-PET/CT (68Ga-DOTA-TOC-PET/CT)
Nebenmilzen finden sich in großen Sektionsstatistiken in 10–15 % der Fälle. Dabei ist das ektope Milzgewebe aufgrund seiner Embryogenese in 80 % der Fälle im Bereich des Milzhilus und nur in 1–2 % im Pankreasschwanz lokalisiert [Meyer T et al. „Intrapankreatische Nebenmilz als Differenzialdiagnose des Pankreasschwanzkarzinomes.“ Zentralblatt für Chirurgie 132.01 (2007): 73–76]. Weitere mögliche Lokalisationen für eine Nebenmilz sind das Ligamentum gastrosplenicum, das Ligamentum splenorenale und das Omentum majus. Article published online: 25 March 2024 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 26 January 2022
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 194 (05) , 549-552
Intrapankreatische Nebenmilz imitiert NET mit falsch positivem Somatostatin-Rezeptor-PET/CT (68Ga-DOTA-TOC-PET/CT)
Nebenmilzen finden sich in großen Sektionsstatistiken in 10–15 % der Fälle. Dabei ist das ektope Milzgewebe aufgrund seiner Embryogenese in 80 % der Fälle im Bereich des Milzhilus und nur in 1–2 % im Pankreasschwanz lokalisiert [Meyer T et al. „Intrapankreatische Nebenmilz als Differenzialdiagnose des Pankreasschwanzkarzinomes.“ Zentralblatt für Chirurgie 132.01 (2007): 73–76]. Weitere mögliche Lokalisationen für eine Nebenmilz sind das Ligamentum gastrosplenicum, das Ligamentum splenorenale und das Omentum majus. Nebenmilzen werden ggf. als Zufallsbefunde im Rahmen einer bildgebenden Diagnostik entdeckt und verursachen dann differenzialdiagnostische Schwierigkeiten in der Abgrenzung zu neuroendokrinen Tumoren oder Metastasen. Die intrapankreatische Nebenmilz zeigt sich als echoreiche bzw. in CT und MRT zum Milzgewebe isodense sowie kontrastmittelanreichernde Struktur. Die Differenzialdiagnose zu malignen Läsionen wie neuroendokrinen Tumoren ist in vielen Fällen schwierig. Hilfreich kann ggf. ein PET-CT oder eine Szintigrafie zum Nachweis von Milzgewebe sein. Publication Date: 26 January 2022 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 26 January 2022
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 194 (05) , 549-552
Intrapankreatische Nebenmilz imitiert NET mit falsch positivem Somatostatin-Rezeptor-PET/CT (68Ga-DOTA-TOC-PET/CT)
Nebenmilzen finden sich in großen Sektionsstatistiken in 10–15 % der Fälle. Dabei ist das ektope Milzgewebe aufgrund seiner Embryogenese in 80 % der Fälle im Bereich des Milzhilus und nur in 1–2 % im Pankreasschwanz lokalisiert [Meyer T et al. „Intrapankreatische Nebenmilz als Differenzialdiagnose des Pankreasschwanzkarzinomes.“ Zentralblatt für Chirurgie 132.01 (2007): 73–76]. Weitere mögliche Lokalisationen für eine Nebenmilz sind das Ligamentum gastrosplenicum, das Ligamentum splenorenale und das Omentum majus. Nebenmilzen werden ggf. als Zufallsbefunde im Rahmen einer bildgebenden Diagnostik entdeckt und verursachen dann differenzialdiagnostische Schwierigkeiten in der Abgrenzung zu neuroendokrinen Tumoren oder Metastasen. Die intrapankreatische Nebenmilz zeigt sich als echoreiche bzw. in CT und MRT zum Milzgewebe isodense sowie kontrastmittelanreichernde Struktur. Die Differenzialdiagnose zu malignen Läsionen wie neuroendokrinen Tumoren ist in vielen Fällen schwierig. Hilfreich kann ggf. ein PET-CT oder eine Szintigrafie zum Nachweis von Milzgewebe sein. Publication Date: 26 January 2022 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany