Kenneth Barker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kenneth Barker has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Steven Chawk
Centre for Sustainable Delivery Glasgow UK
3 shared publicationsMichael Ralph
Public Services Delivery Scotland Edinburgh UK
2 shared publicationsA. Cooper
Department of Anaesthesia Wirral University Teaching Hospital UK
1 shared publicationA. Goddard
Department of Anaesthesia St John's Hospital Livingston UK
1 shared publicationAlexander Lang
NHS Greater Glasgow and Clyde Glasgow UK
1 shared publication- Alison Rutter
Biomedical Sciences, University of the Highlands and Islands, Inverness, UK
1 shared publication
Latest Publications
- 6 August 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1473-1476
The ‘Great Theatre Turn‐off’: what do we need to do?
- 6 August 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1473-1476
The ‘Great Theatre Turn‐off’: what do we need to do?
- Open Access
- 21 July 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1593-1594
Multicentre audit of the efficiency of hospital‐wide central vacuum systems
- 21 July 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1593-1594
Open AccessMulticentre audit of the efficiency of hospital‐wide central vacuum systems
- 21 July 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1595-1596
Multicentre analysis of 7‐bar surgical air provision and use across NHS Scotland
- 21 July 2026
- Published by Wiley in Anaesthesia
- Vol. 81 (11) , 1595-1596
Multicentre analysis of 7‐bar surgical air provision and use across NHS Scotland
- 25 June 2026
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 143 (6) , 1418-1420
Computer Simulation Approach to Assessing Anesthetic Gas Leak Exposure to Theater Staff
- 25 June 2026
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 143 (6) , 1418-1420
Computer Simulation Approach to Assessing Anesthetic Gas Leak Exposure to Theater Staff
- 11 January 2024
- Published by Wiley in Anaesthesia
- Vol. 79 (3) , 261-269
Volatile capture technology in sustainable anaesthetic practice: a narrative review
Summary: Anaesthetic practice contributes to climate change. Volatile capture technology, typically based on adsorption to a carbon‐ or silica‐based substrate, has the potential to mitigate some of the harmful effects of using halogenated hydrocarbons. Anaesthetists have a professional responsibility to use anaesthetic agents which offer the greatest safety and clinical benefit with the lowest financial cost and environmental impacts. Inhalational anaesthetics should be used at an appropriate concentration with a minimal fresh gas flow via a circle system to minimise unnecessary waste. Once practice efficiencies have been maximised, only then should technical solutions such as volatile capture be employed. In this narrative review, we focus on the available literature relating to volatile capture technology, obtained via a targeted literature search and through contacting manufacturers and researchers. We found six studies focusing on the Blue‐Zone Technologies Deltasorb®, SageTech Medical SID and Baxter/ZeoSys CONTRAfluran™ volatile capture systems. Though laboratory analyses of available systems suggest that > 95% in vitro mass transfer is possible for all three systems, the in vivo results for capture efficiency vary from 25% to 73%. Currently, there is no financial incentive for healthcare organisations to capture waste anaesthetic gases, and so the value of volatile capture technology requires quantification. System‐level organisations, such as Greener NHS, are best positioned to commission such evaluations and make policy decisions to guide investment. Further research using volatile capture technology in real‐world settings is necessary and we highlight some priority research questions to improve our understanding of the utility of this group of technologies.
- 11 January 2024
- Published by Wiley in Anaesthesia
- Vol. 79 (3) , 261-269
Volatile capture technology in sustainable anaesthetic practice: a narrative review
Summary: Anaesthetic practice contributes to climate change. Volatile capture technology, typically based on adsorption to a carbon‐ or silica‐based substrate, has the potential to mitigate some of the harmful effects of using halogenated hydrocarbons. Anaesthetists have a professional responsibility to use anaesthetic agents which offer the greatest safety and clinical benefit with the lowest financial cost and environmental impacts. Inhalational anaesthetics should be used at an appropriate concentration with a minimal fresh gas flow via a circle system to minimise unnecessary waste. Once practice efficiencies have been maximised, only then should technical solutions such as volatile capture be employed. In this narrative review, we focus on the available literature relating to volatile capture technology, obtained via a targeted literature search and through contacting manufacturers and researchers. We found six studies focusing on the Blue‐Zone Technologies Deltasorb®, SageTech Medical SID and Baxter/ZeoSys CONTRAfluran™ volatile capture systems. Though laboratory analyses of available systems suggest that > 95% in vitro mass transfer is possible for all three systems, the in vivo results for capture efficiency vary from 25% to 73%. Currently, there is no financial incentive for healthcare organisations to capture waste anaesthetic gases, and so the value of volatile capture technology requires quantification. System‐level organisations, such as Greener NHS, are best positioned to commission such evaluations and make policy decisions to guide investment. Further research using volatile capture technology in real‐world settings is necessary and we highlight some priority research questions to improve our understanding of the utility of this group of technologies.