Sebastian D. Graf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sebastian D. Graf has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Akira Hattesohl
Institute of Pathology, University Hospital Marburg Philipps‐University Marburg Marburg Germany
1 shared publicationAlain Simon
Supplemental Digital Content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Website, www.thoracicimaging.com
1 shared publicationBettina Lehman
Department of Visceral, Thoracic and Vascular Surgery Philipps‐University Marburg Marburg Germany
1 shared publicationCarsten Denkert
Institute of Pathology, University Hospital Marburg Philipps‐University Marburg Marburg Germany
1 shared publication- Corinna Ulrike Keber
Institute of Pathology, Philipps-Universität Marburg, Marburg, Germany
1 shared publication - Damian Craiem
Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMETTyB), Universidad Favaloro-CONICET, Buenos Aires, Argentina
1 shared publication
Latest Publications
- Open Access
- 21 January 2024
- Published by Wiley in Journal of Neuroendocrinology
- Vol. 36 (2) , e13364
Mesenteric fibrosis in patients with small intestinal neuroendocrine tumors is associated with enrichment of alpha‐smooth muscle actin‐positive fibrosis and COMP‐expressing stromal cells
Neuroendocrine tumors of the small intestine (SI‐NETs) often develop lymph node metastasis (LNM)‐induced mesenteric fibrosis (MF). MF can cause intestinal obstruction as well as ischemia and render surgical resection technically challenging. The underlying pathomechanisms of MF are still not well understood. We examined mesenteric LNM and the surrounding stroma compartment from 24 SI‐NET patients, including 11 with in situ presentation of strong MF (MF+) and 13 without MF (MF−). Differential gene expression was assessed with the HTG EdgeSeq Oncology Biomarker Panel comparing MF+ with MF− within LNM and paired stromal samples, respectively. Most interesting differentially expressed genes were validated by reverse transcription‐quantitative polymerase chain reaction (RT‐qPCR) in combination with validation of associated protein levels utilizing immunohistochemistry (IHC) staining of MF+ and MF– formalin‐fixed, paraffin‐embedded (FFPE) patient samples. Overall, 14 genes measured with a 2549‐gene expression panel were differentially expressed in MF+ patients compared to MF−. Of those, nine were differentially expressed genes in LNM and five genes in the stromal tissue (>2‐fold change, p < .05). The top hits included increased COMP and COL11A1 expression in the stroma of MF+ patients compared to MF−, as well as decreased HMGA2, COL6A6, and SLC22A3 expression in LNM of MF+ patients compared to LNM of MF− patients. RT‐qPCR confirmed high levels of COMP and COL11A1 in stroma samples of MF+ compared to MF− patients. IHC staining confirmed the enrichment of α‐smooth muscle actin‐positive fibrosis in MF+ compared to MF− patients with corresponding increase of COMP‐expressing stromal cells in MF+. Since COMP is associated with the known driver for fibrosis development transforming growth factor beta and with a cancer‐associated fibroblasts enriched environment, it seems to be a promising new target for MF research.
- 21 January 2024
- Published by Wiley in Journal of Neuroendocrinology
- Vol. 36 (2) , e13364
Open AccessMesenteric fibrosis in patients with small intestinal neuroendocrine tumors is associated with enrichment of alpha‐smooth muscle actin‐positive fibrosis and COMP‐expressing stromal cells
Neuroendocrine tumors of the small intestine (SI‐NETs) often develop lymph node metastasis (LNM)‐induced mesenteric fibrosis (MF). MF can cause intestinal obstruction as well as ischemia and render surgical resection technically challenging. The underlying pathomechanisms of MF are still not well understood. We examined mesenteric LNM and the surrounding stroma compartment from 24 SI‐NET patients, including 11 with in situ presentation of strong MF (MF+) and 13 without MF (MF−). Differential gene expression was assessed with the HTG EdgeSeq Oncology Biomarker Panel comparing MF+ with MF− within LNM and paired stromal samples, respectively. Most interesting differentially expressed genes were validated by reverse transcription‐quantitative polymerase chain reaction (RT‐qPCR) in combination with validation of associated protein levels utilizing immunohistochemistry (IHC) staining of MF+ and MF– formalin‐fixed, paraffin‐embedded (FFPE) patient samples. Overall, 14 genes measured with a 2549‐gene expression panel were differentially expressed in MF+ patients compared to MF−. Of those, nine were differentially expressed genes in LNM and five genes in the stromal tissue (>2‐fold change, p < .05). The top hits included increased COMP and COL11A1 expression in the stroma of MF+ patients compared to MF−, as well as decreased HMGA2, COL6A6, and SLC22A3 expression in LNM of MF+ patients compared to LNM of MF− patients. RT‐qPCR confirmed high levels of COMP and COL11A1 in stroma samples of MF+ compared to MF− patients. IHC staining confirmed the enrichment of α‐smooth muscle actin‐positive fibrosis in MF+ compared to MF− patients with corresponding increase of COMP‐expressing stromal cells in MF+. Since COMP is associated with the known driver for fibrosis development transforming growth factor beta and with a cancer‐associated fibroblasts enriched environment, it seems to be a promising new target for MF research.
- Open Access
- 1 July 2014
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 29 (4) , 224-232
Identifying the Principal Modes of Variation in Human Thoracic Aorta Morphology
Diagnosis and management of thoracic aorta (TA) disease demand the assessment of accurate quantitative information of the aortic anatomy. We investigated the principal modes of variation in aortic 3-dimensional geometry paying particular attention to the curvilinear portion. Images were obtained from extended noncontrast multislice computed tomography scans, originally intended for coronary calcium assessment. The ascending, arch, and descending aortas of 500 asymptomatic patients (57 ± 9 y, 81% male) were segmented using a semiautomated algorithm that sequentially inscribed circles inside the vessel cross-section. Axial planes were used for the descending aorta, whereas oblique reconstructions through a toroid path were required for the arch. Vessel centerline coordinates and the corresponding diameter values were obtained. Twelve size and shape geometric parameters were calculated to perform a principal component analysis. Statistics revealed that the geometric variability of the TA was successfully explained using 3 factors that account for ∼80% of total variability. Averaged aortas were reconstructed varying each factor in 5 intervals. Analyzing the parameter loadings for each principal component, the dominant contributors were interpreted as vessel size (46%), arch unfolding (22%), and arch symmetry (12%). Variables such as age, body size, and risk factors did not substantially modify the correlation coefficients, although some particular differences were observed with sex. We conclude that vessel size, arch unfolding, and symmetry form the basis for characterizing the variability of TA morphology. The numerical data provided in this study as supplementary material can be exploited to accurately reconstruct the curvilinear shape of normal TAs.
- 1 July 2014
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 29 (4) , 224-232
Open AccessIdentifying the Principal Modes of Variation in Human Thoracic Aorta Morphology
Diagnosis and management of thoracic aorta (TA) disease demand the assessment of accurate quantitative information of the aortic anatomy. We investigated the principal modes of variation in aortic 3-dimensional geometry paying particular attention to the curvilinear portion. Images were obtained from extended noncontrast multislice computed tomography scans, originally intended for coronary calcium assessment. The ascending, arch, and descending aortas of 500 asymptomatic patients (57 ± 9 y, 81% male) were segmented using a semiautomated algorithm that sequentially inscribed circles inside the vessel cross-section. Axial planes were used for the descending aorta, whereas oblique reconstructions through a toroid path were required for the arch. Vessel centerline coordinates and the corresponding diameter values were obtained. Twelve size and shape geometric parameters were calculated to perform a principal component analysis. Statistics revealed that the geometric variability of the TA was successfully explained using 3 factors that account for ∼80% of total variability. Averaged aortas were reconstructed varying each factor in 5 intervals. Analyzing the parameter loadings for each principal component, the dominant contributors were interpreted as vessel size (46%), arch unfolding (22%), and arch symmetry (12%). Variables such as age, body size, and risk factors did not substantially modify the correlation coefficients, although some particular differences were observed with sex. We conclude that vessel size, arch unfolding, and symmetry form the basis for characterizing the variability of TA morphology. The numerical data provided in this study as supplementary material can be exploited to accurately reconstruct the curvilinear shape of normal TAs.