The Thach Pham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
The Thach Pham has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Bui Thi Huong Giang
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
3 shared publications - Co Xuan Dao
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
3 shared publications - Ngoc Son Do
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
3 shared publications - Cong Tan Nguyen
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
2 shared publications - Nguyen Huong Giang
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
2 shared publications - Van Huy Nguyen
Department of Emergency and Critical Care Medicine, Hanoi Medical University, Hanoi, Vietnam
2 shared publications
Latest Publications
- Open Access
- 7 September 2026
- Published by Springer Nature in Scientific Reports
Association between thoracic epidural analgesia and gastrointestinal failure in acute pancreatitis: a prospective exploratory cohort study in Vietnam
Severe acute pancreatitis is characterized by profound inflammation and splanchnic hypoperfusion, which is often exacerbated by opioid-induced bowel dysfunction. We aimed to evaluate the association between thoracic epidural analgesia (TEA) and early gastrointestinal failure (GIF) in this population. In this single-center observational cohort study, patients with severe and predicted severe acute pancreatitis who received either TEA or systemic analgesia (non-TEA cohort) were prospectively evaluated. The primary outcome was the rate of Day 3 GIF (GIF score ≥ 3). The secondary outcome was the cumulative 72-hour systemic fentanyl consumption (mg). Multivariable logistic regression models were used to assess the independent associations of both TEA and opioid consumption with early GIF. A total of 66 patients were included (TEA cohort: n = 32; non-TEA cohort: n = 34). Baseline characteristics, including age, sex and disease severity scores, were comparable between the cohorts. At ICU admission, GIF was highly prevalent, affecting 87.5% of the TEA cohort and 82.4% of the non-TEA cohort. By Day 3, the unadjusted rate of GIF was significantly lower in the TEA cohort compared to the non-TEA cohort (9.4% vs. 32.4%, p = 0.034). However, this association did not reach statistical significance after adjusting for baseline severity (adjusted Odds Ratio: 0.258; 95% CI, 0.062–1.063; p = 0.061). Furthermore, patients receiving TEA consumed significantly less systemic fentanyl over the first 72 h. In the multivariable regression model, cumulative fentanyl consumption was independently associated with an increased risk of Day 3 GIF (adjusted Odds Ratio: 2.17 per 1 mg increase, 95% CI, 1.33–3.54; p = 0.002). In this exploratory cohort, TEA demonstrated no major procedure-related complications. Although its independent association with early resolution of gastrointestinal failure did not reach statistical significance after adjustment, TEA may relate to clinical benefits partly through significant reductions in systemic opioid consumption.
- 7 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessAssociation between thoracic epidural analgesia and gastrointestinal failure in acute pancreatitis: a prospective exploratory cohort study in Vietnam
Severe acute pancreatitis is characterized by profound inflammation and splanchnic hypoperfusion, which is often exacerbated by opioid-induced bowel dysfunction. We aimed to evaluate the association between thoracic epidural analgesia (TEA) and early gastrointestinal failure (GIF) in this population. In this single-center observational cohort study, patients with severe and predicted severe acute pancreatitis who received either TEA or systemic analgesia (non-TEA cohort) were prospectively evaluated. The primary outcome was the rate of Day 3 GIF (GIF score ≥ 3). The secondary outcome was the cumulative 72-hour systemic fentanyl consumption (mg). Multivariable logistic regression models were used to assess the independent associations of both TEA and opioid consumption with early GIF. A total of 66 patients were included (TEA cohort: n = 32; non-TEA cohort: n = 34). Baseline characteristics, including age, sex and disease severity scores, were comparable between the cohorts. At ICU admission, GIF was highly prevalent, affecting 87.5% of the TEA cohort and 82.4% of the non-TEA cohort. By Day 3, the unadjusted rate of GIF was significantly lower in the TEA cohort compared to the non-TEA cohort (9.4% vs. 32.4%, p = 0.034). However, this association did not reach statistical significance after adjusting for baseline severity (adjusted Odds Ratio: 0.258; 95% CI, 0.062–1.063; p = 0.061). Furthermore, patients receiving TEA consumed significantly less systemic fentanyl over the first 72 h. In the multivariable regression model, cumulative fentanyl consumption was independently associated with an increased risk of Day 3 GIF (adjusted Odds Ratio: 2.17 per 1 mg increase, 95% CI, 1.33–3.54; p = 0.002). In this exploratory cohort, TEA demonstrated no major procedure-related complications. Although its independent association with early resolution of gastrointestinal failure did not reach statistical significance after adjustment, TEA may relate to clinical benefits partly through significant reductions in systemic opioid consumption.
- Open Access
- 31 May 2026
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 41 (2) , 335-343
Percutaneous vascular closure technique using parallel closure in extracorporeal membrane oxygenation decannulation: technical note and case series
Background: Achieving safe and effective closure of large-bore femoral arterial access after venoarterial extracorporeal membrane oxygenation (VA-ECMO) decannulation remains challenging. Percutaneous closure with suture-mediated devices is an established alternative to surgical repair for VA-ECMO decannulation. However, the optimal suture configuration is not well defined, and conventional cross-suture placement may have limitations. This study describes a parallel percutaneous closure technique with the potential to improve outcomes and evaluates its initial feasibility and safety.Methods: This prospective case series included 30 adult patients who underwent bedside decannulation from percutaneous femoral VA-ECMO between March 2024 and March 2025. The closure technique involved deploying two Perclose ProGlide devices (Abbott Vascular) in a parallel configuration. The primary endpoints of technical success and vascular complications were assessed clinically and by duplex Doppler ultrasound 24 hours post-procedure.Results: Technical success was achieved in all 30 patients (100%) without surgical conversion or adjunctive vascular intervention. Duplex ultrasound confirmed normal arterial flow in 23 patients (76.7%). Vascular complications included arterial thrombosis (16.7%), dissection (3.3%), and hematoma (3.3%). No patient required reintervention or developed limb ischemia within 24 hours.Conclusions: This preliminary case series suggests that the parallel percutaneous closure technique is feasible and potentially safe for large-bore femoral decannulation following VA-ECMO. Its bedside application under local anesthesia and low rate of early complications support its utility in critical care. Further studies comparing closure configurations and evaluating long-term outcomes are warranted.
- 31 May 2026
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 41 (2) , 335-343
Open AccessPercutaneous vascular closure technique using parallel closure in extracorporeal membrane oxygenation decannulation: technical note and case series
Background: Achieving safe and effective closure of large-bore femoral arterial access after venoarterial extracorporeal membrane oxygenation (VA-ECMO) decannulation remains challenging. Percutaneous closure with suture-mediated devices is an established alternative to surgical repair for VA-ECMO decannulation. However, the optimal suture configuration is not well defined, and conventional cross-suture placement may have limitations. This study describes a parallel percutaneous closure technique with the potential to improve outcomes and evaluates its initial feasibility and safety.Methods: This prospective case series included 30 adult patients who underwent bedside decannulation from percutaneous femoral VA-ECMO between March 2024 and March 2025. The closure technique involved deploying two Perclose ProGlide devices (Abbott Vascular) in a parallel configuration. The primary endpoints of technical success and vascular complications were assessed clinically and by duplex Doppler ultrasound 24 hours post-procedure.Results: Technical success was achieved in all 30 patients (100%) without surgical conversion or adjunctive vascular intervention. Duplex ultrasound confirmed normal arterial flow in 23 patients (76.7%). Vascular complications included arterial thrombosis (16.7%), dissection (3.3%), and hematoma (3.3%). No patient required reintervention or developed limb ischemia within 24 hours.Conclusions: This preliminary case series suggests that the parallel percutaneous closure technique is feasible and potentially safe for large-bore femoral decannulation following VA-ECMO. Its bedside application under local anesthesia and low rate of early complications support its utility in critical care. Further studies comparing closure configurations and evaluating long-term outcomes are warranted.
- Open Access
- 18 January 2024
- Published by SAGE Publications in Sage Open Medicine
- Vol. 12
Efficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Introduction: To decrease the risk of complications from ventilator-associated pneumonia, it is essential to implement preventative measures in all ICU patients. Since 2018, with the help of Japanese experts, we have applied a ventilator-associated pneumonia care bundle with 10 basic standards in patient care and monitoring. Therefore, we conducted a study to evaluate the results of applying 10 solutions to prevent ventilator-associated pneumonia over 24 months. Methods: A cross-sectional descriptive study with longitudinal follow-up for 24 months on 170 mechanically ventilated patients at the Center for Critical Care Medicine, Bach Mai Hospital. According to the Centers for Disease Control (CDC, 2021), the diagnosis of ventilator-associated pneumonia is when pneumonia appears 48 h after intubation by confirmation by at least two doctors. Evaluate compliance with each solution in the care bundle through camera monitoring, medical records, and directly on patients daily. Results: The rate of ventilator-associated pneumonia is 12.9%, the frequency of occurrence is 16.54 of 1000 days. The compliance rate for complete compliance with a 10-item ventilator-associated pneumonia was only 1.8%, while the average value was 84.1%. Average values of compliance with each solution for hand hygiene, head elevation 30–45 degrees, oral hygiene, stopping sedation, breathing circuit management, cuff pressure management, hypoplastic suction, Spontaneous breathing trial (SBT) daily and assessed extubation, mobilization and early leaving bed, ulcer and thrombosis prevention were 96.9%, 97.3%, 99.4%, 81.5%, 99.9%, 99.9%, 86.3%, 83.5%, 49.3%, and 46.4%, respectively. The time to appear ventilator-associated pneumonia in the high compliance group was 46.7 ± 5.0 days, higher than in the low compliance group, 10.3 ± 0.7 days, p < 0.001. Conclusions: A 10-item ventilator-associated pneumonia care bundle has helped reduce the incidence of ventilator-associated pneumonia. To reduce the risk of ventilator-associated pneumonia and shorten ICU and hospital stays, it is essential to fully adhere to subglottic secretion suction, daily SBT, and early mobilization and leaving the bed.
- 18 January 2024
- Published by SAGE Publications in Sage Open Medicine
- Vol. 12
Open AccessEfficacy of compliance with ventilator-associated pneumonia care bundle: A 24-month longitudinal study at Bach Mai Hospital, Vietnam
Introduction: To decrease the risk of complications from ventilator-associated pneumonia, it is essential to implement preventative measures in all ICU patients. Since 2018, with the help of Japanese experts, we have applied a ventilator-associated pneumonia care bundle with 10 basic standards in patient care and monitoring. Therefore, we conducted a study to evaluate the results of applying 10 solutions to prevent ventilator-associated pneumonia over 24 months. Methods: A cross-sectional descriptive study with longitudinal follow-up for 24 months on 170 mechanically ventilated patients at the Center for Critical Care Medicine, Bach Mai Hospital. According to the Centers for Disease Control (CDC, 2021), the diagnosis of ventilator-associated pneumonia is when pneumonia appears 48 h after intubation by confirmation by at least two doctors. Evaluate compliance with each solution in the care bundle through camera monitoring, medical records, and directly on patients daily. Results: The rate of ventilator-associated pneumonia is 12.9%, the frequency of occurrence is 16.54 of 1000 days. The compliance rate for complete compliance with a 10-item ventilator-associated pneumonia was only 1.8%, while the average value was 84.1%. Average values of compliance with each solution for hand hygiene, head elevation 30–45 degrees, oral hygiene, stopping sedation, breathing circuit management, cuff pressure management, hypoplastic suction, Spontaneous breathing trial (SBT) daily and assessed extubation, mobilization and early leaving bed, ulcer and thrombosis prevention were 96.9%, 97.3%, 99.4%, 81.5%, 99.9%, 99.9%, 86.3%, 83.5%, 49.3%, and 46.4%, respectively. The time to appear ventilator-associated pneumonia in the high compliance group was 46.7 ± 5.0 days, higher than in the low compliance group, 10.3 ± 0.7 days, p < 0.001. Conclusions: A 10-item ventilator-associated pneumonia care bundle has helped reduce the incidence of ventilator-associated pneumonia. To reduce the risk of ventilator-associated pneumonia and shorten ICU and hospital stays, it is essential to fully adhere to subglottic secretion suction, daily SBT, and early mobilization and leaving the bed.