Corné Haasjes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Corné Haasjes has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jan‐Willem Maria Beenakker
Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications - Luc van Vught
Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
2 shared publications - T. H. Khanh Vu
Department of Ophthalmology Leiden University Medical Center Leiden The Netherlands
2 shared publications - Coen R. N. Rasch
Leiden University Medical Center
1 shared publication - Gregorius P. M. Luyten
Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication - Grégoire Hein
Independent Researcher
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (127) , 11170
Optiland: Open-Source Optical Design Software in Python
- 4 November 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (127) , 11170
Open AccessOptiland: Open-Source Optical Design Software in Python
- Open Access
- 12 December 2024
- Published by Wiley in Medical Physics
- Vol. 52 (4) , 2330-2339
Patient‐specific mapping of fundus photographs to three‐dimensional ocular imaging
Background: Ocular proton beam therapy (OPT) planning would benefit from an accurate incorporation of fundus photographs, as various intra‐ocular structures, such as the fovea, are not visible on conventional modalities such as Magnetic Resonance Imaging (MRI). However, the use of fundus photographs in OPT is limited, as the eye's optics induce a nonuniform patient‐specific deformation to the images.Purpose: To develop a method to accurately map fundus photographs to three‐dimensional images.Methods: Personalized optical raytracing simulations were performed for 27 subjects, using subject‐specific eye models based on corneal topography, biometry, and MRI. Light rays were traced through the eye for angles of 0°–85° with respect to the optical axis, in steps of 5°. These simulations provided a reference mapping between camera angles and retinal locations and were used to develop a mapping method without raytracing. The accuracy of this and earlier proposed methods was evaluated. Finally, the most accurate method was implemented in RayOcular, an image‐based OPT planning system, and the fundus photography‐based tumor contour was compared with MRI.Results: When a patient‐specific second nodal point is taken as a reference to describe the retinal location, the camera, and retinal angles show a strong linear relation with a small variation between subjects. At a camera angle of 60°, for example, a corresponding retinal angle of 59.9° ± 0.4° (mean ± SD) was found. When this linear relation is used to predict the corresponding retinal location (without raytracing) of a camera angle of 40°, the mean (Euclidian distance) error in the retinal location was 0.02 mm (SD = 0.06 mm), which was significantly (p < 0.001) lower than earlier proposed methods including EYEPLAN 4.16 mm (SD = 0.25 mm), the Lamberth projection −0.12 mm (SD = 0.46 mm) or polar projection 0.26 mm (SD = 0.57 mm). When implemented in the fundus view of RayOcular, the median distance between contours based on MRI and fundus photography was 0.2 mm (IQR = 0.1–0.3 mm).Conclusions: The second nodal point provides a patient‐specific reference for an accurate mapping of fundus photographs to three‐dimensional images with sub‐millimeter errors.
- 12 December 2024
- Published by Wiley in Medical Physics
- Vol. 52 (4) , 2330-2339
Open AccessPatient‐specific mapping of fundus photographs to three‐dimensional ocular imaging
Background: Ocular proton beam therapy (OPT) planning would benefit from an accurate incorporation of fundus photographs, as various intra‐ocular structures, such as the fovea, are not visible on conventional modalities such as Magnetic Resonance Imaging (MRI). However, the use of fundus photographs in OPT is limited, as the eye's optics induce a nonuniform patient‐specific deformation to the images.Purpose: To develop a method to accurately map fundus photographs to three‐dimensional images.Methods: Personalized optical raytracing simulations were performed for 27 subjects, using subject‐specific eye models based on corneal topography, biometry, and MRI. Light rays were traced through the eye for angles of 0°–85° with respect to the optical axis, in steps of 5°. These simulations provided a reference mapping between camera angles and retinal locations and were used to develop a mapping method without raytracing. The accuracy of this and earlier proposed methods was evaluated. Finally, the most accurate method was implemented in RayOcular, an image‐based OPT planning system, and the fundus photography‐based tumor contour was compared with MRI.Results: When a patient‐specific second nodal point is taken as a reference to describe the retinal location, the camera, and retinal angles show a strong linear relation with a small variation between subjects. At a camera angle of 60°, for example, a corresponding retinal angle of 59.9° ± 0.4° (mean ± SD) was found. When this linear relation is used to predict the corresponding retinal location (without raytracing) of a camera angle of 40°, the mean (Euclidian distance) error in the retinal location was 0.02 mm (SD = 0.06 mm), which was significantly (p < 0.001) lower than earlier proposed methods including EYEPLAN 4.16 mm (SD = 0.25 mm), the Lamberth projection −0.12 mm (SD = 0.46 mm) or polar projection 0.26 mm (SD = 0.57 mm). When implemented in the fundus view of RayOcular, the median distance between contours based on MRI and fundus photography was 0.2 mm (IQR = 0.1–0.3 mm).Conclusions: The second nodal point provides a patient‐specific reference for an accurate mapping of fundus photographs to three‐dimensional images with sub‐millimeter errors.
- Open Access
- 4 April 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (96) , 5756
ZOSPy: optical ray tracing in Python through OpticStudio
Zemax OpticStudio (Ansys, Inc) is a commonly used software package for designing optical setups and performing ray tracing simulations. It offers an Application Programming Interface (API) but interacting with this API is complex. Consequently, current ray tracing simulations generally require substantial manual user interaction, which in turn hampers the sharing of methods between scientists. We have therefore developed ZOSPy, a Python package that provides an accessible interface as well as unit tests. As a result, ZOSPy enables scientists to focus more on optical modelling instead of coding and contributes to open science as optical setups and analyses can easily be shared amongst users.
- 4 April 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (96) , 5756
Open AccessZOSPy: optical ray tracing in Python through OpticStudio
Zemax OpticStudio (Ansys, Inc) is a commonly used software package for designing optical setups and performing ray tracing simulations. It offers an Application Programming Interface (API) but interacting with this API is complex. Consequently, current ray tracing simulations generally require substantial manual user interaction, which in turn hampers the sharing of methods between scientists. We have therefore developed ZOSPy, a Python package that provides an accessible interface as well as unit tests. As a result, ZOSPy enables scientists to focus more on optical modelling instead of coding and contributes to open science as optical setups and analyses can easily be shared amongst users.
- Open Access
- 2 January 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (1) , 43
Correction Method for Optical Scaling of Fundoscopy Images: Development, Validation, and First Implementation
Purpose: Although fundus photography is extensively used in ophthalmology, refraction prevents accurate distance measurement on fundus images, as the resulting scaling differs between subjects due to varying ocular anatomy. We propose a PARaxial Optical fundus Scaling (PAROS) method to correct for this variation using commonly available clinical data. Methods: The complete optics of the eye and fundus camera were modeled using ray transfer matrix formalism to obtain fundus image magnification. The subject's ocular geometry was personalized using biometry, spherical equivalent of refraction (RSE), keratometry, and/or corneal topography data. The PAROS method was validated using 41 different eye phantoms and subsequently evaluated in 44 healthy phakic subjects (of whom 11 had phakic intraocular lenses [pIOLs]), 29 pseudophakic subjects, and 21 patients with uveal melanoma. Results: Validation of the PAROS method showed small differences between model and actual image magnification (maximum 3.3%). Relative to the average eye, large differences in fundus magnification were observed, ranging from 0.79 to 1.48. Magnification was strongly inversely related to RSE (R2 = 0.67). In phakic subjects, magnification was directly proportional to axial length (R2 = 0.34). The inverse relation was seen in pIOL (R2 = 0.79) and pseudophakic (R2 = 0.12) subjects. RSE was a strong contributor to magnification differences (1%–83%). As this effect is not considered in the commonly used Bennett–Littmann method, statistically significant differences up to 40% (mean absolute 9%) were observed compared to the PAROS method (P < 0.001). Conclusions: The significant differences in fundus image scaling observed among subjects can be accurately accounted for with the PAROS method, enabling more accurate quantitative assessment of fundus photography.
- 2 January 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (1) , 43
Open AccessCorrection Method for Optical Scaling of Fundoscopy Images: Development, Validation, and First Implementation
Purpose: Although fundus photography is extensively used in ophthalmology, refraction prevents accurate distance measurement on fundus images, as the resulting scaling differs between subjects due to varying ocular anatomy. We propose a PARaxial Optical fundus Scaling (PAROS) method to correct for this variation using commonly available clinical data. Methods: The complete optics of the eye and fundus camera were modeled using ray transfer matrix formalism to obtain fundus image magnification. The subject's ocular geometry was personalized using biometry, spherical equivalent of refraction (RSE), keratometry, and/or corneal topography data. The PAROS method was validated using 41 different eye phantoms and subsequently evaluated in 44 healthy phakic subjects (of whom 11 had phakic intraocular lenses [pIOLs]), 29 pseudophakic subjects, and 21 patients with uveal melanoma. Results: Validation of the PAROS method showed small differences between model and actual image magnification (maximum 3.3%). Relative to the average eye, large differences in fundus magnification were observed, ranging from 0.79 to 1.48. Magnification was strongly inversely related to RSE (R2 = 0.67). In phakic subjects, magnification was directly proportional to axial length (R2 = 0.34). The inverse relation was seen in pIOL (R2 = 0.79) and pseudophakic (R2 = 0.12) subjects. RSE was a strong contributor to magnification differences (1%–83%). As this effect is not considered in the commonly used Bennett–Littmann method, statistically significant differences up to 40% (mean absolute 9%) were observed compared to the PAROS method (P < 0.001). Conclusions: The significant differences in fundus image scaling observed among subjects can be accurately accounted for with the PAROS method, enabling more accurate quantitative assessment of fundus photography.