RERebecca J. Even

Rebecca J. Even

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rebecca J. Even has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Large errors in soil carbon measurements attributed to inconsistent sample processing

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo

    To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal timescales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC data curation used to inform C market exchanges, which could include demonstration projects, model validation, and project verification activities. Further, to better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied in either the sieving, fine-grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks) and thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2, 4, and 2 mm with a rolling pin). A finer grind generally resulted in a lower coefficient of variance, where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind and, lastly, the < 2000 µm grind. Not drying soils in an oven prior to elemental analysis on average resulted in a 3.5 % lower TC and 5 % lower SOC relative to samples dried at 105 °C due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference in % TC and % SIC, predictions of all three soil properties (% TC, % SIC, and % SOC) using Fourier-transformed infrared spectroscopy (FTIR) were in high agreement (R2 = 0.97, 0.99, and 0.90, respectively). For % SOC, quantification by loss on ignition had a relatively low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method. We conclude that sieving to < 2 mm with a mortar and pestle or rolling pin to remove coarse materials, drying soils at 105 °C, and fine-grinding soils prior to elemental analysis are required to improve accuracy and precision of soil C measurements. Moreover, we show promising results using FTIR spectroscopy coupled with predictive modeling for estimating % TC, % SIC, and % SOC in regions where spectral libraries exist.


  • Open Access

    Reply on RC1

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo

    To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.

  • Open Access

    Reply on RC2

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo

    To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.

  • Open Access

    Comment on egusphere-2024-1470

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo

    To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.

  • Open Access

    Large errors in common soil carbon measurements due to sample processing

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo

    To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.


  • Open Access

    Supplementary material to "Large errors in common soil carbon measurements due to sample processing"

    by Rebecca J. Even, Megan B. Machmuller, Jocelyn M. Lavallee, Tamara J. Zelikova, M. Francesca Cotrufo


  • Top Cited Papers

    Distinct, direct and climate‐mediated environmental controls on global particulate and mineral‐associated organic carbon storage

    by Paige M. Hansen, Rebecca Even, Alison E. King, Jocelyn Lavallee, Meagan Schipanski, M. Francesca Cotrufo

    Identifying controls on soil organic carbon (SOC) storage, and where SOC is most vulnerable to loss, are essential to managing soils for both climate change mitigation and global food security. However, we currently lack a comprehensive understanding of the global drivers of SOC storage, especially with regards to particulate (POC) and mineral‐associated organic carbon (MAOC). To better understand hierarchical controls on POC and MAOC, we applied path analyses to SOC fractions, climate (i.e., mean annual temperature [MAT] and mean annual precipitation minus potential evapotranspiration [MAP‐PET]), carbon (C) input (i.e., net primary production [NPP]), and soil property data synthesized from 72 published studies, along with data we generated from the National Ecological Observatory Network soil pits (n = 901 total observations). To assess the utility of investigating POC and MAOC separately in understanding SOC storage controls, we then compared these results with another path analysis predicting bulk SOC storage. We found that POC storage is negatively related to MAT and soil pH, while MAOC storage is positively related to NPP and MAP‐PET, but negatively related to soil % sand. Our path analysis predicting bulk SOC revealed similar trends but explained less variation in C storage than our POC and MAOC analyses. Given that temperature and pH impose constraints on microbial decomposition, this indicates that POC is primarily controlled by SOC loss processes. In contrast, strong relationships with variables related to plant productivity constraints, moisture, and mineral surface availability for sorption indicate that MAOC is primarily controlled by climate‐driven variations in C inputs to the soil, as well as C stabilization mechanisms. Altogether, these results demonstrate that global POC and MAOC storage are controlled by separate environmental variables, further justifying the need to quantify and model these C fractions separately to assess and forecast the responses of SOC storage to global change.